Difference between revisions of "Materials:PermaFlash"
Difference between revisions of "Materials:PermaFlash"
(Created page with "{| class="wikitable" |- | style="background-color: #ffffcc; column-width:100%" | '''Notice to the Reader''': The roofing assembly / material information published in the RCA...") |
|||
(2 intermediate revisions by the same user not shown) | |||
Line 9: | Line 9: | ||
| '''Manufacturer''': [http://www.jm.com/ '''Johns Manville Corporation'''] | | '''Manufacturer''': [http://www.jm.com/ '''Johns Manville Corporation'''] | ||
;: | ;: | ||
− | ;Accepted for '''''RoofStar Guarantee Program''''': | + | ;Accepted for '''''RoofStar Guarantee Program''''': 2008 |
;: | ;: | ||
− | ;'''Product Summary''': | + | ;'''Product Summary''': '''PermaFlash™''' is a flexible flashing system specially designed to work with a variety of bituminous roofing systems to ensure the weatherproofing of a wide range of details. It is a liquid applied two part system consisting of a polyester reinforcing scrim and MBR® Flashing Cement for superior bonding and durability. |
− | + | ||
+ | :'''PermaFlash™''' scrim is a stitch bonded polyester scrim that is both sturdy and pliable to accommodate any shape and provide the reinforcing substrate for the MBR® Flashing Cement. It can even be used on drains and vertical surfaces such as pipes and column penetrations. The systems flexibility allows it to accommodate normal roof movement to retain its weatherability. | ||
+ | |||
+ | :'''PermaFlash™''' is easily applied in any location. Because the primer dries rapidly, the process moves quickly. Mixing the MBR® Flashing Cement can be done in the original 19 litre (5 gallon) containers. It stays workable under a wide range of temperatures but cures to form a seamless barrier with exceptional strength and flexibility. For those who prefer a method other than mixing, MBR® Flashing Cement Cartridges are also available. These cartridges contain the two component adhesive and require the use of an MBR® Flashing Cement applicator and static mixer. For more information about this product, visit [http://www.jm.com/ '''Johns Manville Corporation''']. | ||
+ | |||
+ | :;Uses: | ||
+ | :PermaFlash is specifically formulated for use with all bituminous systems, including hybrid systems. It is excellent for use in projects such as: | ||
+ | :* New and re-roof | ||
+ | :* Metal roofing | ||
+ | :* Paver systems | ||
+ | :* Historic preservation and / or restoration | ||
+ | |||
+ | :;Features: | ||
+ | :* Low permeability | ||
+ | :* Wide application temperature range | ||
+ | :* Low cost per penetration | ||
+ | :* Minimal odour release | ||
+ | :* Great tensile strength | ||
+ | :* Enhanced workability | ||
+ | :* Great crack bridging capabilities | ||
+ | |||
+ | :<table border="1" cellspacing="0" cellpadding="2"> | ||
+ | <tr> | ||
+ | <td nowrap><strong>Property</strong></td> | ||
+ | <td nowrap><strong>Test Method</strong></td> | ||
+ | <td nowrap><strong>Value</strong></td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td nowrap>Colour</td> | ||
+ | <td nowrap>Visual</td> | ||
+ | <td nowrap>Black</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td nowrap>Nominal Thickness with Scrim</td> | ||
+ | <td nowrap>Micrometer</td> | ||
+ | <td nowrap>2.0 mm (80 mil.) Minimum</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td nowrap>Tensile Strength</td> | ||
+ | <td nowrap>ASTM D 412</td> | ||
+ | <td nowrap>7.6 MPa (1100 psi)</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td nowrap>Elongation</td> | ||
+ | <td nowrap>ASTM D 412</td> | ||
+ | <td nowrap>> 40%</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td valign="top" nowrap>Permeability to Water Vapour</td> | ||
+ | <td nowrap>ASTM E 96 Method E, 38°C (100°F), 2.5 mm (100 mil) sheet</td> | ||
+ | <td valign="top" nowrap>.03 Perms</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td nowrap>Hardness</td> | ||
+ | <td nowrap>ASTM D 2240 @ 25°C (77°F)</td> | ||
+ | <td nowrap>65 Shore A</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td nowrap>Working Time*</td> | ||
+ | <td nowrap>@ 24°C (75°F)</td> | ||
+ | <td nowrap>30 Minutes</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td nowrap>Rainproof After*</td> | ||
+ | <td nowrap>@ 24°C (75°F)</td> | ||
+ | <td nowrap>4 Hours</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td nowrap>Suitable for Pedestrian Traffic*</td> | ||
+ | <td nowrap>@ 24°C (75°F)</td> | ||
+ | <td nowrap>12 Hours</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td nowrap>Suitable for Vehicular Traffic*</td> | ||
+ | <td nowrap>@ 24°C (75°F)</td> | ||
+ | <td nowrap>48 Hours</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td nowrap>Overburden May Be Applied After*</td> | ||
+ | <td nowrap>@ 24°C (75°F)</td> | ||
+ | <td nowrap>24 Hours</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td nowrap>Crack Bridging</td> | ||
+ | <td nowrap>After Heat Aging</td> | ||
+ | <td nowrap>3 mm (<sup>1</sup>⁄<sub>8</sub>")</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td nowrap>Softening Point, Ring & Ball</td> | ||
+ | <td nowrap>ASTM D 36</td> | ||
+ | <td nowrap>135°C (275°F)</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td nowrap>Elastomeric Waterproofing</td> | ||
+ | <td nowrap>ASTM C 836, ASTM C 957</td> | ||
+ | <td nowrap>Exceeds All Criteria</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td valign="top" nowrap>Abrasion Resistance</td> | ||
+ | <td nowrap>ASTM D 4060, 1000 gr. / 1000 rev. CS-17 Wheel</td> | ||
+ | <td valign="top" nowrap>1.2 mg Loss</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td nowrap>VOC</td> | ||
+ | <td nowrap> </td> | ||
+ | <td nowrap>88 grams / litre (0.74 lbs. / gallon)</td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | |||
+ | :* Working and cure times will vary depending on ambient surface and material temperatures. | ||
|} | |} | ||
− | :Click below for the '''Technical Data Sheet''' | + | :Click below for the '''Technical Data Sheet''' |
<div style="width:150px; text-align: left;"> | <div style="width:150px; text-align: left;"> | ||
− | :[[File:Pdf.png|150 px|'''Technical Data Sheet''']] | + | :[[File:Pdf.png|150 px|link=http://rpm.rcabc.org/images/4/41/JM_Perma_Flash_System_TDS.pdf|'''Technical Data Sheet''']] |
</div> | </div> | ||
Latest revision as of 14:31, 18 April 2018
Notice to the Reader:
The roofing assembly / material information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications. The preparation of a detailed specification is the responsibility of the design authority. |
Manufacturer: Johns Manville Corporation
|
- Click below for the Technical Data Sheet