Difference between revisions of "Template:Using CSA A123.21-Page Header"
Difference between revisions of "Template:Using CSA A123.21-Page Header"
Line 1: | Line 1: | ||
− | <big>USING | + | <big>USING TESTED ASSEMBLY REPORTS</big> |
− | The tables and products shown below provide basic material data related to roof assemblies tested for their performance in modulating and high winds. They also provide links to more information about the materials, including manufacturers' published Technical Data sheets. The reader is advised to use this information in conjunction with other RoofStar-accepted Materials, and with reference to roof system requirements derived from from appropriate wind uplift calculations (see the '''[http://www.nrc-cnrc.gc.ca/eng/services/windrci/agreement.html Wind-RCI]''' calculator and reference notes and requirements outlined in [http://rpm.rcabc.org/index.php?title= | + | The tables and products shown below provide basic material data related to roof assemblies tested for their performance in modulating and high winds, using the test method found in CSA A123.21. They also provide links to more information about the materials, including manufacturers' published Technical Data sheets. The reader is advised to use this information in conjunction with other RoofStar-accepted Materials, and with reference to roof system requirements derived from from appropriate wind uplift calculations (see the '''[http://www.nrc-cnrc.gc.ca/eng/services/windrci/agreement.html Wind-RCI]''' calculator and reference notes and requirements outlined in [http://rpm.rcabc.org/index.php?title=Securing_the_Roof_Assembly '''Securing the Roof Assembly''']). The information on this page is not intended for use as a comparison of material performance or quality. Nor should this information be construed as an endorsement of the suitability of any given material for a particular application. It is the sole responsibility of the design authority to assess the performance capability and material suitability for specific design requirements. |
<hr> | <hr> | ||
<div class="toccolours mw-collapsible mw-collapsed"><div class="mw-collapsible-content"> | <div class="toccolours mw-collapsible mw-collapsed"><div class="mw-collapsible-content"> | ||
− | Roof Assemblies are classified according to three different attachment approaches: '''MARS''' (Mechanically Attached Roof Systems), '''PARS''' (Partially Adhered Roof Systems), and '''AARS''' (Adhesive Applied Roof Systems). For a full explanation of these and other key details pertinent to an understanding of the test reports, visit [http://rpm.rcabc.org/index.php?title= | + | Roof Assemblies are classified according to three different attachment approaches: '''MARS''' (Mechanically Attached Roof Systems), '''PARS''' (Partially Adhered Roof Systems), and '''AARS''' (Adhesive Applied Roof Systems). For a full explanation of these and other key details pertinent to an understanding of the test reports, visit [http://rpm.rcabc.org/index.php?title=Securing_the_Roof_Assembly '''Securing the Roof Assembly''']. |
In the tables below, the following definitions apply: | In the tables below, the following definitions apply: | ||
:'''ASSEMBLIES''' are represented by the downloadable reports linked in the far right column of each table. '''Assemblies''' are defined in this Manual as the arrangement of various and distinct roofing materials in layers, secured to the roof deck by a variety of methods. The Accepted Material which is listed in the second column of each table is included in the associated Assembly wind uplift test reports, which may be downloaded using the links in the far right column of each table. The RCABC has renumbered these reports for tracking purposes. The official report numbers will be found on the documents themselves. | :'''ASSEMBLIES''' are represented by the downloadable reports linked in the far right column of each table. '''Assemblies''' are defined in this Manual as the arrangement of various and distinct roofing materials in layers, secured to the roof deck by a variety of methods. The Accepted Material which is listed in the second column of each table is included in the associated Assembly wind uplift test reports, which may be downloaded using the links in the far right column of each table. The RCABC has renumbered these reports for tracking purposes. The official report numbers will be found on the documents themselves. | ||
− | :The tested assembly reports use the language of "systems" to reflect how the CSA A123.21 Standard uses the term: to refer to the different spacing of fasteners or adhesive ribbons. Some '''Assemblies''' have been tested with a variety of fastener or adhesive patterns, others with only one. For example, one Assembly may be tested with three different fastener spacing arrangements, indicated both by the row spacing and by the fastener spacing. In that case, the tables show that a material has been tested with three different | + | :The tested assembly reports use the language of "systems" to reflect how the CSA A123.21 Standard uses the term: to refer to the different spacing of fasteners or adhesive ribbons (NOTE: the use of ''System'' elsewhere in the RPM denotes the combination of roof materials, excluding the supporting deck structure. The two uses of the term should not be confused). Some '''Assemblies''' have been tested with a variety of fastener or adhesive patterns or ''systems'', others with only one. For example, one Assembly may be tested with three different fastener spacing arrangements (''systems''), indicated both by the row spacing and by the fastener spacing. In that case, the tables show that a material has been tested with three different ''systems''. You will see notations in the third column of each table indicating how many attachment ''systems'' have been tested for a particular material. The associated report will be found on the same line, in the far right column. |
:Some of the reports will include diagrams or photographs illustrating the tested patterns. Click on a report link for a complete description of the test results and all other materials tested in the assembly ('''NOTE''': Most reports are under 2 MB in size but some are considerably larger and may exceed your server capacity) | :Some of the reports will include diagrams or photographs illustrating the tested patterns. Click on a report link for a complete description of the test results and all other materials tested in the assembly ('''NOTE''': Most reports are under 2 MB in size but some are considerably larger and may exceed your server capacity) |
Revision as of 15:26, 15 April 2019
USING TESTED ASSEMBLY REPORTS
The tables and products shown below provide basic material data related to roof assemblies tested for their performance in modulating and high winds, using the test method found in CSA A123.21. They also provide links to more information about the materials, including manufacturers' published Technical Data sheets. The reader is advised to use this information in conjunction with other RoofStar-accepted Materials, and with reference to roof system requirements derived from from appropriate wind uplift calculations (see the Wind-RCI calculator and reference notes and requirements outlined in Securing the Roof Assembly). The information on this page is not intended for use as a comparison of material performance or quality. Nor should this information be construed as an endorsement of the suitability of any given material for a particular application. It is the sole responsibility of the design authority to assess the performance capability and material suitability for specific design requirements.