| '''Manufacturer''': [http://www.tremcoroofing.com '''Tremco Ltd.''']
 
| '''Manufacturer''': [http://www.tremcoroofing.com '''Tremco Ltd.''']
 
;:  
 
;:  
;Accepted for '''''RoofStar Guarantee Program''''': Date TBA
+
;Accepted for '''''RoofStar Guarantee Program''''': June 1988
 
;:
 
;:
;'''Product Summary''': TBA
+
;'''Product Summary''': The upgraded built-up roof is a waterproofing roof system composed of five plies of #15 organic felts, adhered and glazed coated with hot applications of asphalt.  Flashings incorporate 2 plies of Polytherm adhered and overcoated with the appropriate adhesive.  The application is completed with a specifically engineered Tremco top pour and gravelling.
 +
 
 +
:Ancillary products:
 +
:* Cutback Primer (Tremprime Q.E.)
 +
:* THERMastic
 +
:* Mastics (ELS, Fibremat, Polyroof, Sheeting Bond and Tremlastic)
 +
:* BURmastic base sheet (coated cold-processed felt)
 +
:* Burmesh woven glass reinforcing membrane
 +
:* Flashing membrane (Tremco Elastomeric Sheeting or Tremco Polytherm)
 +
:* gravel (see the RPM for grade standards)
 
;:
 
;:
 
;[[Tremco BUR Installation Guidelines|BUR Installation Guidelines]]
 
;[[Tremco BUR Installation Guidelines|BUR Installation Guidelines]]

Latest revision as of 17:05, 15 October 2019

Notice to the Reader:

The roofing assembly / material information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications. The preparation of a detailed specification is the responsibility of the design authority.

Manufacturer: Tremco Ltd.
Accepted for RoofStar Guarantee Program
June 1988
Product Summary
The upgraded built-up roof is a waterproofing roof system composed of five plies of #15 organic felts, adhered and glazed coated with hot applications of asphalt. Flashings incorporate 2 plies of Polytherm adhered and overcoated with the appropriate adhesive. The application is completed with a specifically engineered Tremco top pour and gravelling.
Ancillary products:
  • Cutback Primer (Tremprime Q.E.)
  • THERMastic
  • Mastics (ELS, Fibremat, Polyroof, Sheeting Bond and Tremlastic)
  • BURmastic base sheet (coated cold-processed felt)
  • Burmesh woven glass reinforcing membrane
  • Flashing membrane (Tremco Elastomeric Sheeting or Tremco Polytherm)
  • gravel (see the RPM for grade standards)
BUR Installation Guidelines
Click below for the Technical Data Sheet (TBA).
Technical Data Sheet



Back to Accepted Materials