Difference between revisions of "Table Drafts 4"
Difference between revisions of "Table Drafts 4"
(→Part 9: TPO Table (Combined 5, 10, 15)) |
(→Part 9: PVC Table (Combined 5, 10, 15)) |
||
Line 101: | Line 101: | ||
{| class="wikitable mw-datatable" style="margin-left: 10pt; margin-right: auto;border-color:#E7E9E9;vertical-align:top;text-align:top;" | {| class="wikitable mw-datatable" style="margin-left: 10pt; margin-right: auto;border-color:#E7E9E9;vertical-align:top;text-align:top;" | ||
− | |+ Table 9. | + | |+ Table 9.1 PVC Membranes: RoofStar 5, 10 & 15-year Guarantees<br><small>(Applies to Field and Flashing membranes. All thicknesses shown are in mm.)</small> |
! colspan="2" style="border:none; background-color:#E7E9E9" | | ! colspan="2" style="border:none; background-color:#E7E9E9" | | ||
! colspan="4" rowspan="1" style="vertical-align:center;text-align:center;background-color:#A9A9A9" | <span style="color:#f8f9fa">Exposed Roof Systems</span> !! rowspan="20" style="border: none; background-color:#E7E9E9" | | ! colspan="4" rowspan="1" style="vertical-align:center;text-align:center;background-color:#A9A9A9" | <span style="color:#f8f9fa">Exposed Roof Systems</span> !! rowspan="20" style="border: none; background-color:#E7E9E9" | |
Revision as of 21:38, 11 December 2020
1 Part 9: EPDM Table (Combined 5, 10, 15)
Exposed Roof Systems | Protected Roof Systems | Grade-level Water- proofing | |||||||
---|---|---|---|---|---|---|---|---|---|
Conventionally Insulated / Uninsulated Systems | Built-in Gutters |
Ballasted | PMR Systems | ||||||
Mechanically Fastened or Induction Welded* |
Self-adhered | Adhered or Hot-mopped |
Adhered or Self-adhered |
Loose-laid | Self-adhered, Adhered or Hot-mopped |
Self-adhered, Adhered or Hot-mopped | |||
Type, Reinforcement, Grade | Guarantee Term | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | |
EPDM (reinforced) | |||||||||
5 | 1.524 (60) | 1.524 (60) | 1.143 (45) | 1.524 (60) | 1.143 (45) | 1.143 (45) | |||
10 | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | |||
15 | 2.286 (90) | 1.524 (60) | |||||||
EPDM (unreinforced) | |||||||||
5 | 1.524 (60) | 1.143 (45) | 1.524 (60) | 1.143 (45) | 1.143 (45) | ||||
10 | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | ||||
15 | 2.286 (90) | 2.286 (90) | 2.286 (90) |
- *Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.
2 Part 9: TPO Table (Combined 5, 10, 15)
Exposed Roof Systems | Protected Roof Systems | Grade-level Water- proofing | |||||||
---|---|---|---|---|---|---|---|---|---|
Conventionally Insulated / Uninsulated Systems | Built-in Gutters |
Ballasted | PMR Systems | ||||||
Mechanically Fastened or Induction Welded* |
Self-adhered | Adhered or Hot-mopped |
Adhered or Self-adhered |
Loose-laid | Self-adhered, Adhered or Hot-mopped |
Self-adhered, Adhered or Hot-mopped | |||
Type, Reinforcement, Grade | Guarantee Term | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | |
TPO | |||||||||
5 | xxxx | xxxx | xxxx | xxxx | xxxx | xxxx | xxxx | ||
10 | xxxx | xxxx | xxxx | xxxx | xxxx | xxxx | xxxx | ||
15 | xxxx | xxxx | xxxx | xxxx | xxxx | xxxx | xxxx |
- *Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.
3 Part 9: PVC Table (Combined 5, 10, 15)
Exposed Roof Systems | Protected Roof Systems | Grade-level Water- proofing | |||||||
---|---|---|---|---|---|---|---|---|---|
Conventionally Insulated / Uninsulated Systems | Built-in Gutters |
Ballasted | PMR Systems | ||||||
Mechanically Fastened or Induction Welded* |
Self-adhered | Adhered or Hot-mopped |
Adhered or Self-adhered |
Loose-laid | Self-adhered, Adhered or Hot-mopped |
Self-adhered, Adhered or Hot-mopped | |||
Type, Reinforcement, Grade | Guarantee Term | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | |
PVC | |||||||||
5 | xxxx | xxxx | xxxx | xxxx | xxxx | xxxx | xxxx | ||
10 | xxxx | xxxx | xxxx | xxxx | xxxx | xxxx | xxxx | ||
15 | xxxx | xxxx | xxxx | xxxx | xxxx | xxxx | xxxx |
- *Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.