Table Drafts 4

Jump to: navigation, search

Table Drafts 4

Draft page for Soprema (Vegetated Roof Systems)



Division C - Accepted Materials


Soprema Inc.
Associate Member (Manufacturer)

Systems/Materials Listed by Category under Tabs Above


The information published in the RCABC Roofing Practices Manual and offered under each tab does NOT represent a complete set of the manufacturer’s data or specifications, nor is any listed system or material recommended or endorsed by the Guarantor. The preparation of a detailed specification is the responsibility of the Design Authority.

Website
https://www.soprema.ca/
Contact Address
See the current Membership list and contact information at www.rcabc.org
Country of Origin
France
Country of Manufacture
Canada, France, Germany, Switzerland, U.S.A.
Year First Installed
BC: 1979
Canada: 1979
Foreign: 1976
Notice and Disclaimer: Technical Data Sheets for SBS and APP Polymer-modified bituminous membranes


Bituminous roofing membranes are governed by RGC Acceptance Criteria RGC ACWP-MOD (applicable to membranes accepted after July 1, 2023). The CSA Standard for these membranes, CSA A123.23 "Product specification for polymer modified bitumen sheet, prefabricated and reinforced", forms the backbone of the RGC Acceptance Criteria and has replaced the older CGSB Standard CGSB 37-GP-56M, which was withdrawn in 2015.

The "British Columbia Building Code" (2024) references the CSA A123.23 Standard in both Part 5 and Part 9 of Division B. The Standard is also published in the National Building Code of Canada (2020), and the City of Vancouver Building Bylaw (2024).

Not all manufacturers of SBS and APP polymer-modified membranes publish technical data sheets that fully align with the CSA Standard. Therefore, the reader must verify this information independently of the RGC, to the reader's own satisfaction. Consult the local manufacturer's representative through the "Find a Member" page on the RCABC association website.


Insulation

XPS Insulation
Polyisocyanurate Insulation
Mineral Fibre Insulation

Insulation Overlay Panels

Asphaltic Overlays
High-density Insulation Overlays
Membrane-laminated Overlays

Felts (BUR)

Glass Felts

SBS Polymer-Modified Bituminous Membranes (Cont.)

(See the membrane tables in Division C)

Cap Sheets

PVC Membranes

(See the membrane tables in Division C)

Hot Fluid-applied Rubberized Asphalt Membranes

(See the membrane tables in Division C)

PMMA Membranes (System)

(See the membrane tables in Division C)

Liquid Membrane Flashing Systems

(See the membrane tables in Division C)

Two-Component Reinforced Liquid Membrane Flashing

Single-Component Liquid Membrane Flashing


Underlayment/Eave Protection (Asphalt Shingles/Cedar/Tiles)

Mechanically Fastened Materials
Self-adhered Materials

Underlayment/Eave Protection (ASM)

Self-adhered Materials

Insulation

XPS Insulation

PVC Membranes

(See the membrane tables in Division C)


Hot Fluid-applied Rubberized Asphalt Membranes

(See the membrane tables in Division C)

PMMA Membranes (System)

(See the membrane tables in Division C)


Liquid Membrane Flashing Systems

(See the membrane tables in Division C)

Two-part Reinforced Liquid Membrane Flashing

Vegetated Roof Systems
An Accessory is a material that joins Primary or Secondary Materials together, or is connected to/with a Primary or Secondary material, but does not by its nature (apart from its installation) directly affect the water or wind resistance of the Waterproofing or Water-shedding system. An Accessory is not an Accepted Material and therefore the RoofStar Guarantee does not extend to cover any potential material or installation failure. Accessories are listed in the Roofing Practices Manual merely for reference to specifiers, designers and installers.