Difference between revisions of "Template:Materials - Insulation (EPS)"
Difference between revisions of "Template:Materials - Insulation (EPS)"
Line 1: | Line 1: | ||
− | {| class="wikitable sortable" style="margin-left: 20pt; margin-right: auto; border: none;" | + | {| class="wikitable sortable mw-datatable" style="margin-left: 20pt; margin-right: auto; border: none;" |
− | |+ Click on a manufacturer's name to see the full list of their products accepted for use in the RoofStar Guarantee Program | + | |+ EPS Insulation<br><small>Click on a manufacturer's name to see the full list of their products accepted for use in the RoofStar Guarantee Program. NOTE: materials linked to Tested Assembly tables may be displayed separately or located only in Tested Assembly reports.</small> |
− | ! style="width: | + | ! style="width:450px;vertical-align:top;" | Manufacturer |
− | ! style=" | + | ! style="vertical-align:top;width:300px;" | Product Name |
! style="width:80px;vertical-align:top;" | System Test Type ([http://rpm.rcabc.org/index.php?title=Wind_Uplift_Design_and_CSA_A123.21 Wind]) | ! style="width:80px;vertical-align:top;" | System Test Type ([http://rpm.rcabc.org/index.php?title=Wind_Uplift_Design_and_CSA_A123.21 Wind]) | ||
! style="vertical-align:top;" | Density (kg/cu. m) | ! style="vertical-align:top;" | Density (kg/cu. m) | ||
− | ! style="vertical-align:top;" | Compressive Strength (kPa) | + | ! style="vertical-align:top;" | Compressive<br>Strength<br>(kPa) |
− | ! style="vertical-align:top;" | Compressive Strength (psi) | + | ! style="vertical-align:top;" | Compressive<br>Strength<br>(psi) |
− | ! style="vertical-align:top;" | Thermal Resistance (RSI/25.4 mm) | + | ! style="vertical-align:top;" | Thermal<br>Resistance<br>(RSI/25.4 mm) |
− | ! style="vertical-align:top;" | Thermal Resistance (R/inch) | + | ! style="vertical-align:top;" | Thermal<br>Resistance<br>(R/inch) |
|- | |- | ||
| '''[[Airfoam Industries Ltd.]]''' || [[Materials:Korolite 100 (Type 1, Flat)| Korolite 100 (Type 1, Flat)]] || style="text-align:center;"| ‒ || style="text-align:center;"| ‒ || style="text-align:center;"| 70 || style="text-align:center;"| 10 || style="text-align:center;"| 0.65 || style="text-align:center;"| 3.75 | | '''[[Airfoam Industries Ltd.]]''' || [[Materials:Korolite 100 (Type 1, Flat)| Korolite 100 (Type 1, Flat)]] || style="text-align:center;"| ‒ || style="text-align:center;"| ‒ || style="text-align:center;"| 70 || style="text-align:center;"| 10 || style="text-align:center;"| 0.65 || style="text-align:center;"| 3.75 | ||
|- | |- | ||
− | | '''[[Airfoam Industries Ltd.]]''' || [[Materials:Korolite | + | | '''[[Airfoam Industries Ltd.]]''' || [[Materials:Korolite 100 (Type 1, Flat)| Korolite 100 (Type 1, Flat)]] || style="text-align:center;"| ‒ || style="text-align:center;"| ‒ || style="text-align:center;"| 110 || style="text-align:center;"| 16 || style="text-align:center;"| 0.7 || style="text-align:center;"| 4.04 |
|- | |- | ||
| '''[[Airfoam Industries Ltd.]]''' || [[Materials:Korolite 250 (Type 3, Flat)| Korolite 250 (Type 3, Flat)]] || style="text-align:center;"| ‒ || style="text-align:center;"| ‒ || style="text-align:center;"| 172 || style="text-align:center;"| 25 || style="text-align:center;"| 0.74 || style="text-align:center;"| 4.27 | | '''[[Airfoam Industries Ltd.]]''' || [[Materials:Korolite 250 (Type 3, Flat)| Korolite 250 (Type 3, Flat)]] || style="text-align:center;"| ‒ || style="text-align:center;"| ‒ || style="text-align:center;"| 172 || style="text-align:center;"| 25 || style="text-align:center;"| 0.74 || style="text-align:center;"| 4.27 | ||
Line 28: | Line 28: | ||
|| '''[[Plasti-Fab]]''' || [[Materials:Plastispan 25 Insulation (Type 3)|Plastispan 25 Insulation (Type 3)]] || style="text-align:center;"| ‒ || style="text-align:center;"| ‒ || style="text-align:center;"| 140 || style="text-align:center;"| 20 || style="text-align:center;"| 0.74 || style="text-align:center;"| 4.27 | || '''[[Plasti-Fab]]''' || [[Materials:Plastispan 25 Insulation (Type 3)|Plastispan 25 Insulation (Type 3)]] || style="text-align:center;"| ‒ || style="text-align:center;"| ‒ || style="text-align:center;"| 140 || style="text-align:center;"| 20 || style="text-align:center;"| 0.74 || style="text-align:center;"| 4.27 | ||
|- | |- | ||
− | || '''[[Plasti-Fab]]''' || [[Materials:Plastispan Sloped Insulation|Plastispan Sloped Insulation]] || style="text-align:center;"| ‒ || style="text-align:center;"| | + | || '''[[Plasti-Fab]]''' || [[Materials:Plastispan Sloped Insulation|Plastispan Sloped Insulation]] || style="text-align:center;"| ‒ || style="text-align:center;"| ‒ || style="text-align:center;"| ‒ || style="text-align:center;"| ‒ || style="text-align:center;"| ‒ || style="text-align:center;"| ‒ |
|- | |- | ||
|} | |} |
Revision as of 14:38, 29 June 2021
Manufacturer | Product Name | System Test Type (Wind) | Density (kg/cu. m) | Compressive Strength (kPa) |
Compressive Strength (psi) |
Thermal Resistance (RSI/25.4 mm) |
Thermal Resistance (R/inch) |
---|---|---|---|---|---|---|---|
Airfoam Industries Ltd. | Korolite 100 (Type 1, Flat) | ‒ | ‒ | 70 | 10 | 0.65 | 3.75 |
Airfoam Industries Ltd. | Korolite 100 (Type 1, Flat) | ‒ | ‒ | 110 | 16 | 0.7 | 4.04 |
Airfoam Industries Ltd. | Korolite 250 (Type 3, Flat) | ‒ | ‒ | 172 | 25 | 0.74 | 4.27 |
Airfoam Industries Ltd. | Korolite 100 (Type 1, Tapered) | ‒ | ‒ | 70 | 10 | 0.65 | 3.75 |
Airfoam Industries Ltd. | Korolite 160 (Type 2, Tapered) | ‒ | ‒ | 110 | 16 | 0.7 | 4.04 |
Airfoam Industries Ltd. | Korolite 250 (Type 3, Tapered) | ‒ | ‒ | 172 | 25 | 0.74 | 4.27 |
Plasti-Fab | Plastispan Insulation (Type 1) | ‒ | ‒ | 70 | 10 | 0.65 | 3.75 |
Plasti-Fab | Plastispan HD Insulation (Type 2) | ‒ | ‒ | 110 | 16 | 0.7 | 4.04 |
Plasti-Fab | Plastispan 25 Insulation (Type 3) | ‒ | ‒ | 140 | 20 | 0.74 | 4.27 |
Plasti-Fab | Plastispan Sloped Insulation | ‒ | ‒ | ‒ | ‒ | ‒ | ‒ |