=== Standing Seam Metal Roof System - Job Site Roll-forming ===
+
{| class="wikitable" | style="color: black; background-color: orange; width: 100%;text-align:center"
 +
| colspan="2"  | <big>To view materials in any section listed below, click on the <span style="color:#6495ed">'''Expand'''</span> button located at the right hand side of this page</big>
 +
|}
 +
=== [[Air and Vapour Control|Air and Vapour Control]] ===
 +
:The RCABC does not list air or vapour barriers in the [http://rpm.rcabc.org/index.php?title=Materials_by_Product_Type '''Accepted Materials'''] section of this Manual, as their performance is not guaranteed by the '''''RoofStar Guarantee Program'''''.  For more about air and vapour barriers and specific requirements for the '''''RoofStar Guarantee Program''''', select any of the [http://rpm.rcabc.org/index.php?title=Low_Slope_Membrane_Roofs '''Low Slope Membrane Roof Systems'''].  This cross-reference is listed for information only.
  
<div class="toccolours mw-collapsible mw-collapsed"><div class="mw-collapsible-content">{{Materials - Site-Formed Metal Roofing Systems}}</div>
+
<div class="toccolours mw-collapsible mw-collapsed">
  
=== Proprietary Metal Roof Systems (Manufactured in Plant Roll-forming) ===
+
===[[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMDECK| Deck Overlay Boards]]===
 +
<div class="mw-collapsible-content">{{Materials - Deck Overlay Boards}}</div>
 +
</div>
  
RCABC Guarantee Corp. (RGC) accepted proprietary standing seam metal roof systems, installed in conformance with '''''RoofStar Guarantee Standards''''', qualify for a five (5) or ten (10) year guarantee under the RoofStar Guarantee Program.
+
===[[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMINS | Insulation]] ===
 +
<div class="toccolours mw-collapsible mw-collapsed">
 +
:<big><big>Composite Board Insulation</big></big>
 +
<div class="mw-collapsible-content">{{Materials - Insulation (Composite Board)}}</div>
 +
</div>
 +
<div class="toccolours mw-collapsible mw-collapsed">
 +
:<big><big>XPS (Extruded Expanded Polystyrene Foam)</big></big>
 +
<div class="mw-collapsible-content">{{Materials - Insulation (XPS)}}</div>
 +
</div>
 +
<div class="toccolours mw-collapsible mw-collapsed">
 +
:<big><big>EPS (Expanded Polystyrene Foam)</big></big>
 +
<div class="mw-collapsible-content">{{Materials - Insulation (EPS)}}</div>
 +
</div>
 +
<div class="toccolours mw-collapsible mw-collapsed">
 +
:<big><big>Polyisocyanurate Foam</big></big>
 +
<div class="mw-collapsible-content">{{Materials - Insulation (Polyisocyanurate)}}</div>
 +
</div>
 +
<div class="toccolours mw-collapsible mw-collapsed">
 +
:<big><big>Perlitic Insulation</big></big>
 +
<div class="mw-collapsible-content">{{Materials - Insulation (Perlitic)}}</div>
 +
</div>
 +
<div class="toccolours mw-collapsible mw-collapsed">
 +
:<big><big>Mineral Fibre Roof Insulation</big></big>
 +
<div class="mw-collapsible-content">{{Materials - Insulation (Mineral Fibre)}}</div>
 +
</div>
  
<div class="toccolours mw-collapsible mw-collapsed"><div class="mw-collapsible-content">{{Materials - Proprietary Metal Roof Systems}}</div>
+
=== [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMINS|Insulation Overlay Boards]] ===
 +
<div class="toccolours mw-collapsible mw-collapsed">
 +
:<big><big>Composite Insulation Overlays</big></big>
 +
<div class="mw-collapsible-content">{{Materials - Insulation Overlay (Composite Board)}}</div>
 +
</div>
  
===Deck Overlay===
+
<div class="toccolours mw-collapsible mw-collapsed">
  
===Insulation===
+
===[[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMUND |Eave and Detail Protection]]===
:[http://{{SERVERNAME}}/index.php?title=Insulating_the_Roof#3.2Composite <big><big>Composite Board Insulation</big></big>]
+
<div class="mw-collapsible-content">{{Template:Materials - ASM Eave Protection & Underlayment}}</div>
<div class="toccolours mw-collapsible mw-collapsed"><div class="mw-collapsible-content">{{Materials - Insulation (Composite Board)}}</div>
+
</div>
  
===Insulation Overlay Board===
+
=== [[RoofStar Guarantee Standards for ASM Systems#ASMPANELS| Standing Seam Metal Roof System - Job Site Roll-forming]]===
 +
:All architectural metal roofing accepted for application in the RoofStar Guarantee Program utilizes a locking standing seam.  There are three seam types currently offered with site-formed metal roofing systems (click on a type to see an illustration).  Refer to the table below for a summary of panel manufacturers and the products they supply:
 +
#'''[[Mechanically locking]]'''
 +
#'''[[Snap-together]]'''
 +
#'''[[Snap-together with cap]]'''
 +
<div class="toccolours mw-collapsible mw-collapsed">
 +
:Note that not all panels are made with stiffener ribs.  Refer to each manufacturer's literature by clicking on the product name in the table.
 +
<div class="mw-collapsible-content">{{Materials - Site-Formed Metal Roofing Systems}}</div>
 +
</div>
  
===ASM Underlayment===
+
=== Proprietary Metal Roof Systems (Manufactured in Plant Roll-forming) ===
 
+
<div class="toccolours mw-collapsible mw-collapsed">
<div class="toccolours mw-collapsible mw-collapsed"><div class="mw-collapsible-content">{{Template:Materials - ASM Eave Protection & Underlayment}}</div>
+
:RoofStar-accepted proprietary standing seam metal roof systems, installed in conformance with '''''RoofStar Guarantee Standards''''', qualify for a five (5) or ten (10) year guarantee under the '''''RoofStar Guarantee Program'''''.
 +
<div class="mw-collapsible-content">{{Materials - Proprietary Metal Roof Systems}}</div>
 +
</div>
  
 
<hr>
 
<hr>
  
  
 +
[[ASM (Architectural Sheet Metal) Roof Assemblies|<i class="fa fa-chevron-circle-left" ></i> ''Home - ASM Roof Assemblies'']]
  
 +
[[Materials by Product Type |<i class="fa fa-chevron-circle-left" ></i> ''Accepted Materials'']]
  
[[ASM (Architectural Sheet Metal) Roof Systems|<i class="fa fa-chevron-circle-left" ></i> ''ASM Roof Systems'']]
+
[[ASM Application Guides and Notes|<i class="fa fa-chevron-circle-right" ></i> ''ASM Application Guides and Notes'']]
 
 
[[ASM Application|<i class="fa fa-chevron-circle-right" ></i> ''Application'']]
 

Latest revision as of 20:33, 26 July 2021


To view materials in any section listed below, click on the Expand button located at the right hand side of this page

1 Air and Vapour Control

The RCABC does not list air or vapour barriers in the Accepted Materials section of this Manual, as their performance is not guaranteed by the RoofStar Guarantee Program. For more about air and vapour barriers and specific requirements for the RoofStar Guarantee Program, select any of the Low Slope Membrane Roof Systems. This cross-reference is listed for information only.

2 Deck Overlay Boards

Deck overlays are materials installed over decks to render the surface suitable for waterproofing materials. Click on a manufacturer's name to see the full list of their products accepted for use in the RoofStar Guarantee Program

* Use treated plywood over concrete deck surfaces
Manufacturer Product Name Product Type Thickness
mm (in.)
Weight
(lb/square foot)
Comp. Strength
(psi, nominal)
Acceptable
Application
Plywood Plywood overlay 12.7 (1/2) min. Variable - All decks*
Georgia-Pacific Canada Ltd. DensDeck Roofboard Moisture-resistant gypsum core board 6.4 (1/4) 1.100 500-900 All decks
Georgia-Pacific Canada Ltd. DensDeck Roofboard Moisture-resistant gypsum core board 12.7 (1/2) 1.950 500-900 All decks
Georgia-Pacific Canada Ltd. DensDeck Roofboard Moisture-resistant gypsum core board 15.9 (5/8) 2.500 500-900 All decks
Georgia-Pacific Canada Ltd. DensDeck® Prime with EONIC Roof Board Moisture-resistant gypsum core board 6.4 (1/4) 1.150 900 All decks
Georgia-Pacific Canada Ltd. DensDeck® Prime with EONIC Roof Board Moisture-resistant gypsum core board 12.7 (1/2) 1.975 900 All decks
Georgia-Pacific Canada Ltd. DensDeck® Prime with EONIC Roof Board Moisture-resistant gypsum core board 15.9 (5/8) 2.550 900 All decks
USG (CGC) SecureRock Securerock Glass-Mat Roof Board Moisture-resistant gypsum core board 6.4 (1/4) 1.200 700-1000 All decks
USG (CGC) SecureRock Securerock Glass-Mat Roof Board Moisture-resistant gypsum core board 12.7 (1/2) 2.000 700-1000 All decks
USG (CGC) SecureRock Securerock Glass-Mat Roof Board Moisture-resistant gypsum core board 15.9 (5/8) 2.700 700-1000 All decks
USG (CGC) SecureRock Securerock Gypsum Fibre Roof Board Moisture-resistant gypsum core board 6.4 (1/4) 1.570 1800 All decks
USG (CGC) SecureRock Securerock Gypsum Fibre Roof Board Moisture-resistant gypsum core board 9.5 (3/8) 1.960 1800 All decks
USG (CGC) SecureRock Securerock Gypsum Fibre Roof Board Moisture-resistant gypsum core board 12.7 (1/2) 2.760 1800 All decks
USG (CGC) SecureRock Securerock Gypsum Fibre Roof Board Moisture-resistant gypsum core board 15.9 (5/8) 3.200 1800 All decks
USG (CGC) SecureRock Securerock Coated Ultralight Glass Mat Roof Board* 6.4 (1/4) 1.200 700-1000 700-1000 All decks
USG (CGC) SecureRock Securerock Coated Ultralight Glass Mat Roof Board* 12.7 (1/2) 1.700 700-1000 700-1000 All decks
USG (CGC) SecureRock Securerock Coated Ultralight Glass Mat Roof Board* 15.9 (5/8) 2.200 700-1000 700-1000 All decks
USG (CGC) SecureRock Securerock Ultralight Glass Mat Roof Board Moisture-resistant gypsum core board 6.4 (1/4) 1.200 700-1000 All decks
USG (CGC) SecureRock Securerock Ultralight Glass Mat Roof Board Moisture-resistant gypsum core board 12.7 (1/2) 1.700 700-1000 All decks
USG (CGC) SecureRock Securerock Ultralight Glass Mat Roof Board Moisture-resistant gypsum core board 15.9 (5/8) 2.200 700-1000 All decks
* Indicates conditions of acceptance. See the product page for more information.

3 Insulation

Composite Board Insulation
Click on a manufacturer's name to see the full list of their products accepted for use in the RoofStar Guarantee Program
Manufacturer Product Name System Test Type (Wind) Density (kg/cu. m) Compressive Strength (kPa/25.4 mm) Compressive Strength (psi/1 in. thick) Thermal Resistance (RSI/25.4 mm) Thermal Resistance (R/inch)
Posi-Slope Western MF (Protect Board Composite)
Soprema Inc. Xpress Board HD 200 190 (at 25%) 28 (at 25%) 0.70 K/W 4
Soprema Inc. Xpress ISO 138 (Polyiso only) 20 (Polyiso only) 1.0 5.7
XPS (Extruded Expanded Polystyrene Foam)
XPS Insulation
Click on a manufacturer's name to see the full list of their products accepted for use in the RoofStar Guarantee Program. NOTE: materials linked to Tested Assembly tables may be displayed separately or located only in Tested Assembly reports.
Manufacturer Product Name System Test Type (Wind) Density (kg/cu. m) Compressive
Strength
(kPa)
Compressive
Strength
(psi)
Thermal
Resistance
(RSI/25.4 mm)
Thermal
Resistance
(R/inch)
Dupont Specialty Products Division - Safety and Construction Deckmate (Type 2) 110 16 0.87 5
Dupont Specialty Products Division - Safety and Construction Deckmate Plus (Type 3) 140 20 0.87 5
Dupont Specialty Products Division - Safety and Construction Roofmate (Type 4) 240 35 0.87 5
Dupont Specialty Products Division - Safety and Construction Roofmate CT (Type 4) 240* 35* 0.87 5
Owens Corning Canada Foamular C200 (Type 3) 140 20 0.88 5
Owens Corning Canada Foamular F350 (Type 4) 240 35 0.88 5
Owens Corning Canada Foamular 400 (Type 4) 275 40 0.88 5
Owens Corning Canada Foamular 600 (Type 4) 415 60 0.88 5
Owens Corning Canada Foamular 1000 (Type 4) 690 100 0.88 5
Owens Corning Canada Foamular 404 (Type 4) 276 40 0.88 5
Owens Corning Canada Foamular 604 (Type 4) 414 60 0.88 5
Owens Corning Canada Foamular 404RB (Type 4) 276 40 0.84 4.75
Owens Corning Canada Foamular 604RB (Type 4) 414 60 0.84 4.75
Soprema Inc. Sopra-XPS 35 350 51 0.88 5
Soprema Inc. Sopra-XPS 40, 60, 100 500, 600, 700 73, 87, 102 0.88 5
EPS (Expanded Polystyrene Foam)
EPS Insulation
Click on a manufacturer's name to see the full list of their products accepted for use in the RoofStar Guarantee Program. NOTE: materials linked to Tested Assembly tables may be displayed separately or located only in Tested Assembly reports.
Manufacturer Product Name System Test Type (Wind Uplift Resistance) Compressive
Strength
(kPa)
Compressive
Strength
(psi)
Thermal
Resistance
(RSI/25.4 mm)
@24°C (74°F)
Thermal
Resistance
(R/inch)
@24°C (74°F)
Airfoam Industries Ltd. Korolite 100 (Type 1, Flat) 70 10 0.65 3.75
Airfoam Industries Ltd. Korolite 160 (Type 2, Flat) 110 16 0.7 4.04
Airfoam Industries Ltd. Korolite 250 (Type 3, Flat) 172 25 0.74 4.27
Airfoam Industries Ltd. Korolite 100 (Type 1, Tapered) 70 10 0.65 3.75
Airfoam Industries Ltd. Korolite 160 (Type 2, Tapered) 110 16 0.7 4.04
Airfoam Industries Ltd. Korolite 250 (Type 3, Tapered) 172 25 0.74 4.27
Beaver Plasticts Ltd. Terrafoam (Type 1, Flat) 70 10 0.65 3.75
Beaver Plasticts Ltd. Terrafoam (Type 2, Flat) 110 16 0.7 4.04
Beaver Plasticts Ltd. Terrafoam (Type 3, Flat) 140 20.4 0.74 4.27
Beaver Plasticts Ltd. Terrafoam (Type 1, Tapered) 70 10 0.65 3.75
Beaver Plasticts Ltd. Terrafoam (Type 2, Tapered) 110 16 0.7 4.04
Beaver Plasticts Ltd. Terrafoam (Type 3, Tapered) 140 20.4 0.74 4.27
Plasti-Fab Plastispan Insulation (Type 1) 70 10 0.65 3.75
Plasti-Fab Plastispan HD Insulation (Type 2) 110 16 0.7 4.04
Plasti-Fab Plastispan 25 Insulation (Type 3) 140 20 0.74 4.27
Plasti-Fab Plastispan Sloped Insulation
Polyisocyanurate Foam
"Polyiso" Insulation
Click on a manufacturer's name to see the full list of their products accepted for use in the RoofStar Guarantee Program. NOTE: materials linked to Tested Assembly tables may be displayed separately or located only in Tested Assembly reports.
Manufacturer Product Name System Test Type (Wind) Density (kg/m3) Compressive
Strength
(kPa)
Compressive
Strength
(psi)
Thermal
Resistance
(RSI/25.4 mm)
Thermal
Resistance
(R/inch)
Atlas Roofing Corporation AC Foam III 32 138 20 1 5.7
Atlas Roofing Corporation AC Foam Supreme 32 138 20 1 5.7
Carlisle Syntec Systems Canada SecurShield HD Plus MARS PARS 138 20 1 5.7
Carlisle Syntec Systems Canada SecurShield RapidLock (RL) Polyiso 138 20 1 5.7
Carlisle Syntec Systems Canada SecurShield RapidLock (RL) HD Polyiso 138 20 1 5.7
Elevate (fomerly Firestone) ISOGARD CG 32 138 20 1 5.7
Hunter Panels H-Shield CG 32 138 20 1 5.7
Hunter Panels H-Shield Premier 32 138 20 1 5.7
Hunter Panels H-Shield Composite 32 138 20 1 5.7
IKO Industries Ltd. IKOTherm III 140 20 1 5.7
Johns Manville Corporation ENRGY 3 CGF Insulation 138 20 1 5.7
Polyglass USA, Inc. Polytherm G 32.04 138 20 1 5.7
Siplast, Inc. Paratherm CG 138 20 1 5.7
Soprema Inc. Sopra-Iso Plus 32 138 20 1 5.7
Perlitic Insulation
Click on a manufacturer's name to see the full list of their products accepted for use in the RoofStar Guarantee Program
Manufacturer Product Name System Test Type (Wind) Density (kg/cu. m) Compressive Strength (kPa) Compressive Strength (psi) Thermal Resistance (RSI) Thermal Resistance (R/inch)
Johns Manville Corporation Fesco Board 0.49 2.78
Mineral Fibre Roof Insulation
Mineral Fibre Insulation
Click on a manufacturer's name to see the full list of their products accepted for use in the RoofStar Guarantee Program. NOTE: materials linked to Tested Assembly tables may be displayed separately or located only in Tested Assembly reports.
Manufacturer Product Name System Test Type (Wind) Density (kg/cu. m) Compressive
Strength
(kPa)
Compressive
Strength
(psi)
Thermal
Resistance
(RSI/25.4 mm)
Thermal
Resistance
(R/inch)
ROCKWOOL TOPROCK® DD See TDS See TDS See TDS 0.62 3.5
ROCKWOOL TOPROCK® DD PLUS See TDS See TDS See TDS 0.62 3.5
ROCKWOOL MULTIFIX TM See TDS See TDS See TDS 0.68 3.8
Soprema Inc. Soprarock DD See TDS See TDS See TDS 0.62 3.5
Soprema Inc. Soprarock DD PLUS See TDS See TDS See TDS 0.62 3.5
Soprema Inc. Soprarock MD See TDS See TDS See TDS See TDS See TDS
Soprema Inc. Soprarock MD Plus See TDS See TDS See TDS See TDS See TDS

4 Insulation Overlay Boards

5 Eave and Detail Protection

Eave protection is used to protect the eave and valley areas of water-shedding roofs from ice dam damage. An ice dam usually forms when the interior heat of the building warms the snow on the roof, causing it to melt and run down to the eaves. Normally, eaves extend past the exterior face of the building and are not heated from the inside. This allows the water to freeze and form an ice dam. As the ice dam grows, it forms a barrier that prevents water from draining off the edge of the eaves. The water backs up behind the dam and gradually forces its way under the primary roof covering (asphalt shingles, metal panels, cedar shakes or shingles, etc.), where it warms and melts (the result of heat leakage through discontinuities in the air barrier system). Liquid water then leaks through the roof deck and into the structure. The results can range from minor staining to severe water damage to the structural members.

Eave protection membranes are designed to prevent the water from reaching the deck and leaking into the structure. These materials are self-adhering and manufactured with a rubberized asphaltic compound, or with butyl. Properly formulated and installed, these sheets have the potential to perform a long time. Slope and climate conditions are considerations for selection; refer to the Standard for further information and guidance.

Underlayment is used in the field areas of the roof (where eave protection is not required) to provide a secondary protection beneath the roof covering, during weather events that might force water underneath.


Notice to Reader
* Eave and Valley Protection - Some of the materials listed in the columns for eave or valley protection must be installed in multiple layers because, by themselves, they are too thin to satisfy the material requirements published in the Standard for Architectural Sheet Metal (ASM) Roof Systems. Consult the product manufacturer for appropriate application requirements, and the Standard for multiple layering requirements. If multi-layering is not permitted by the manufacturer, select a product with suitable thickness that may be applied in a single layer.
Underlayment - While some materials listed as underlayments are nail-applied, their acceptability is dependent on roof slope. Refer to Part 8 in the Standard for Architectural Sheet Metal (ASM) Roof Systems before specifying or installing nail-applied materials; nail-applied underlayments are not permitted on slopes less than 1:3 (4" in 12").

Manufacturer Product Name Product Type Top Surface Separation
Layer
Eaves &
Valleys*
Under-
layment
Nominal Thickness
mm (mil)
Application Method
Click up/down arrows to sort
Various No. 30 Asphalt Felt Felt underlayment Non-woven Felt X X Nail-applied
Building Products of Canada Corp. Gripgard SBS-modified Bituminous X Self-adhering
Building Products of Canada Corp. Weathertex (SA) SBS-modified Bituminous Sanded X 1.5 (60) Self-adhering
CertainTeed LLC DiamondDeck Polymeric Synthetic Polymer X N/A Nail-applied
CertainTeed LLC RoofRunner AIR Polymeric Synthetic Polymer X 0.56 (22) Nail-applied
CertainTeed LLC WinterGuard Pro SBS Modified Bituminous Synthetic Polymer 1.14 (45) Self-adhering
Elevate (fomerly Firestone) Clad-Gard SA SBS-modified Bituminous Woven Polyethylene 1.00 (40) Self-adhering
Elevate (fomerly Firestone) Clad-Gard MA SBS-modified Bituminous X N/A Self-adhering
FT Synthetics PLATINUM Polymeric Polyolefin X 0.50 (20) Nail-applied
FT Synthetics SILVER Polymeric Polyolefin X 0.30 (12) Nail-applied
FT Synthetics PLATINUM HT-SA Polymeric GRIPSPOT TM 1.04 (41) Self-adhering
FT Synthetics Platinum HT-B Polymeric GRIPSPOT TM * 1.04 (41) Self-adhering
FT Synthetics Cobalt Ultra Polymeric GRIPSPOT TM 1.04 (41) Self-adhering
GAF Canada ULC Stormguard SBS-modified Bituminous X 1.02 (40) Self-adhering
GAF Canada ULC Deck Armor Polymeric X Nail-applied
GAF Canada ULC FeltBuster Polymeric non-slip X Nail-applied
Garland Canada Inc. R-Mer Seal polymer/rubberized asphalt adhesive Slip-resist. Polymer 1.14 (45) Self-adhering
Garland Canada Inc. Viking UDL Metal polymer/rubberized asphalt adhesive Polyester 1.52 (60) Self-adhering
HAL Industries Inc. “Super” Tilemate G100 FW SBS-modified Bituminous Woven Polypropylene 1.00 (40) Self-adhering
Henry Company Canada Blueskin PE 200 HT SBS-modified Bituminous Polyethylene 1.00 (40) Self-adhering
Henry Company Canada Blueskin RF 200 SBS-modified Bituminous Slip-resistant Film 1.00 (40) Self-adhering
Henry Company Canada Eaveguard SBS-modified Bituminous Sanded X 1.30 (50) Self-adhering
IKO Industries Ltd. Stormshield Ice and Water Protector SBS-modified Bituminous Sanded X 1.08 (43) Self-adhering
IKO Industries Ltd. 44 Stormshield Ice and Water Protector SBS-modified Bituminous Sanded X 1.08 (43) Self-adhering
IKO Industries Ltd. Armourgard Ice and Water Protector SBS-modified Bituminous Sanded X 1.4 (53) Self-adhering
KPNE Products Ltd. ULTRASeal SA HT Polymeric/Self-adhering butyl Slip-resist. polymer X 1.14 (45) Self-adhering
Malarkey Roofing Products Right Start™ UDL SBS-modified Bituminous Sanded X X 1.40 (55) Nail-applied
Malarkey Roofing Products Arctic Seal Ice & Water Guard SBS-modified Bituminous Sanded X X 1.52 (60) Self-adhering
Malarkey Roofing Products Secure Start Plus Polymeric Slip-resist. polymer X Nail-applied
Malarkey Roofing Products Secure Start SG Polymeric Smooth polymeric X Nail-applied
Malarkey Roofing Products Secure Start Permeable Polymeric Polymeric X Nail-applied
Owens Corning Canada LP Titanium UDL 25 Polymeric Synthetic (not stated) X 0.38 (15) Nail-applied
Owens Corning Canada LP Titanium UDL 30 Polymeric Synthetic (not stated) X 0.63 (25) Nail-applied
Owens Corning Canada LP Titanium UDL 50 Polymeric Synthetic (not stated) X 0.75 (30) Nail-applied
Owens Corning Canada LP Titanium PSU 30 SBS-modified Bituminous Synthetic Polymer 1.10 (45) Self-adhering
Owens Corning Canada LP RhinoRoof U20 Polymeric Not Stated X X 0.18 (7) Nail-applied
Polyglass USA, Inc. Polystick MTS Proprietary Compound Fibreglass mat X 1.50 (60) Self-adhering
Protecto Wrap Company Jiffy Seal Ice and Water Guard HT SBS-modified Bituminous Woven polyolefin 1.00 (40) Self-adhering
Protecto Wrap Company Jiffy Seal Butyl Ice and Water Guard HT SBS-modified Bituminous Woven polyolefin 0.75 (30) Self-adhering
Sentry Building Innovations Roofnado AnchorDeck Polymeric Not Stated X Nail-applied
Sentry Building Innovations Roofnado LapLock PSU (HT) Polymeric/Self-adhered underside Polymeric Self-adhering
Sentry Building Innovations StormTread XW Polymeric Not Stated X Nail-applied
Sentry Building Innovations Sahara (underlayment) Polymeric Not Stated X Nail-applied
Sentry Building Innovations Sahara AnchorDeck (underlayment) Polymeric Not Stated X Nail-applied
Siplast Paradiene 20 EG SA SBS-modified Bituminous Not Stated X 3.00 (118) Self-adhering
Soprema Inc. Lastobond 195 SBS-modified Bituminous Sanded X 1.60 (63) Self-adhering
Soprema Inc. Lastobond 240 SBS-modified Bituminous Sanded X 1.60 (63) Self-adhering
Soprema Inc. Lastobond Shield SBS-modified Bituminous Woven polyethylene 1.00 (40) Self-adhering
Soprema Inc. Lastobond Shield HT SBS-modified Bituminous Woven polyethylene 1.00 (40) Self-adhering
Soprema Inc. Sopraseal Stick 1100 T SBS-modified Bituminous Woven polyethylene 1.00 (40) Self-adhering
Soprema Inc. Sopraply Stick Duo SBS-modified Bituminous Sanded X 3.00 (120) Self-adhering
Soprema Inc. Lastobond Stick VP SBS-modified Bituminous Trilaminar polypropylene X 0.6 (24) Self-adhering
VaproShield LLC SlopeShield Plus Self-Adhered Polymeric Trilaminar polypropylene X 0.51 (20) Self-adhering

6 Standing Seam Metal Roof System - Job Site Roll-forming

All architectural metal roofing accepted for application in the RoofStar Guarantee Program utilizes a locking standing seam. There are three seam types currently offered with site-formed metal roofing systems (click on a type to see an illustration). Refer to the table below for a summary of panel manufacturers and the products they supply:
  1. Mechanically locking
  2. Snap-together
  3. Snap-together with cap
Note that not all panels are made with stiffener ribs. Refer to each manufacturer's literature by clicking on the product name in the table.

7 Proprietary Metal Roof Systems (Manufactured in Plant Roll-forming)

RoofStar-accepted proprietary standing seam metal roof systems, installed in conformance with RoofStar Guarantee Standards, qualify for a five (5) or ten (10) year guarantee under the RoofStar Guarantee Program.


Home - ASM Roof Assemblies

Accepted Materials

ASM Application Guides and Notes