Difference between revisions of "Materials:JM TPO"

Jump to: navigation, search

Difference between revisions of "Materials:JM TPO"

m (James Klassen moved page Materials:JM TPO Membrane to Materials:JM TPO)
 
(5 intermediate revisions by the same user not shown)
Line 9: Line 9:
 
| '''Manufacturer''': [http://www.jm.com/  '''Johns Manville Corporation''']
 
| '''Manufacturer''': [http://www.jm.com/  '''Johns Manville Corporation''']
 
;:  
 
;:  
;Accepted for '''''RoofStar Guarantee Program''''': Date TBA
+
;Accepted for '''''RoofStar Guarantee Program''''': 2008
 
;:
 
;:
;'''Product Summary''': TBA
+
;'''Product Summary''':
 +
:JM TPO-45, JM TPO-60, and JM TPO-80 are thermoplastic polyolefin (TPO) membranes reinforced with a polyester fabric, and designed for use in mechanically fastened and adhered roofing applications.
 +
 
 +
:'''Use'''
 +
:JM TPO membranes can be installed in new, reroof (tear-off) and recover roof constructions. In recover construction, if the existing roof is sound, the JM roof can eliminate the cost of disposing of the original roof.
 +
 
 +
:'''Colors'''
 +
:White, Grey and Tan
 +
:Special colors are available with extended lead times. Minimum order quantities may apply. Contact your local JM sales representative for additional information.
 +
 
 +
:'''Approvals'''
 +
:JM mechanically fastened and adhered TPO Roof Systems are classified by UL (Underwriters Laboratories, Inc.) and FM Global (Factory Mutual).
 +
 
 +
:'''Installation'''
 +
:Because JM TPO membranes are thermoplastic, they can be rolled out onto the roof substrate and easily welded into one homogeneous sheet using hot air welding procedures.  JM TPO membranes also may be mechanically attached or adhered to the structural roof deck in accordance with FM Global requirements, building codes, published standard fastening patterns or adhesives recommendations.
 +
 
 +
:Refer to JM TPO application guides, Detail Drawings and Technical Bulletins for instructions.
 +
 
 +
:JM TPO membranes meet or exceed all of the requirements of ASTM D 6878.
 +
 
 +
:Refer to the Material Safety Data Sheet prior to using JM TPO. Material Safety Data Sheet is available by calling 800-654-3103 or online at www.jm.com.
 +
;:
 +
;[[Johns Manville TPO Membrane Installation Guidelines|Installation Guidelines]]
 
|}
 
|}
  
:Click below for the '''Technical Data Sheet''' (TBA).
+
:Click below for the '''Technical Data Sheet'''
  
<div style="width:150px; text-align: left;">
+
<div class="col-md-2">
:[[File:Pdf.png|150 px|'''Technical Data Sheet''']]
+
:[[File:Pdf.png|150 px|link=http://rpm.rcabc.org/images/c/ca/JM_TPO_45_mil_TDS.pdf|'''Technical Data Sheet (45 mil)''']]
 +
<div style="text-align: center;">
 +
:1.11 mm (45 mil) Membrane TDS
 +
</div>
 +
</div>
 +
<div class="col-md-2">
 +
:[[File:Pdf.png|150 px|link=http://rpm.rcabc.org/images/6/6e/JM_TPO_60mil_TDS.pdf|'''Technical Data Sheet (60 mil)''']]
 +
<div style="text-align: center;">
 +
:1.52 mm (60 mil) Membrane TDS
 +
</div>
 +
</div>
 +
<div class="col-md-2">
 +
:[[File:Pdf.png|150 px|link=http://rpm.rcabc.org/images/c/c9/JM_TPO_80mil_TDS.pdf|'''Technical Data Sheet (90 mil)''']]
 +
<div style="text-align: center;">
 +
:2.03 mm (90 mil) Membrane TDS
 +
</div>
 
</div>
 
</div>
  
 
+
<div class="col-md-12">
 
<hr>
 
<hr>
  
Line 27: Line 64:
  
 
[[Main Page|Home]]
 
[[Main Page|Home]]
 +
</div>

Latest revision as of 22:06, 28 July 2021

Notice to the Reader:

The roofing assembly / material information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications. The preparation of a detailed specification is the responsibility of the design authority.

Manufacturer: Johns Manville Corporation
Accepted for RoofStar Guarantee Program
2008
Product Summary
JM TPO-45, JM TPO-60, and JM TPO-80 are thermoplastic polyolefin (TPO) membranes reinforced with a polyester fabric, and designed for use in mechanically fastened and adhered roofing applications.
Use
JM TPO membranes can be installed in new, reroof (tear-off) and recover roof constructions. In recover construction, if the existing roof is sound, the JM roof can eliminate the cost of disposing of the original roof.
Colors
White, Grey and Tan
Special colors are available with extended lead times. Minimum order quantities may apply. Contact your local JM sales representative for additional information.
Approvals
JM mechanically fastened and adhered TPO Roof Systems are classified by UL (Underwriters Laboratories, Inc.) and FM Global (Factory Mutual).
Installation
Because JM TPO membranes are thermoplastic, they can be rolled out onto the roof substrate and easily welded into one homogeneous sheet using hot air welding procedures. JM TPO membranes also may be mechanically attached or adhered to the structural roof deck in accordance with FM Global requirements, building codes, published standard fastening patterns or adhesives recommendations.
Refer to JM TPO application guides, Detail Drawings and Technical Bulletins for instructions.
JM TPO membranes meet or exceed all of the requirements of ASTM D 6878.
Refer to the Material Safety Data Sheet prior to using JM TPO. Material Safety Data Sheet is available by calling 800-654-3103 or online at www.jm.com.
Installation Guidelines
Click below for the Technical Data Sheet
Technical Data Sheet (45 mil)
1.11 mm (45 mil) Membrane TDS
Technical Data Sheet (60 mil)
1.52 mm (60 mil) Membrane TDS
Technical Data Sheet (90 mil)
2.03 mm (90 mil) Membrane TDS