Difference between revisions of "ASM Eave Protection and Underlayment (Low Slopes)"
Difference between revisions of "ASM Eave Protection and Underlayment (Low Slopes)"
Line 1: | Line 1: | ||
{{Template:RPM Info}} | {{Template:RPM Info}} | ||
− | + | <hr> | |
{| class="wikitable" | style="color: black; background-color: orange; width: 100%;text-align:center" | {| class="wikitable" | style="color: black; background-color: orange; width: 100%;text-align:center" | ||
| colspan="2" | <big>'''''Notice to Reader'''''</big> | | colspan="2" | <big>'''''Notice to Reader'''''</big> | ||
|- | |- | ||
− | | style="color: black; background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and | + | | style="color: black; background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they necessarily drawn to scale. Rather, they are provided to visually convey the requirements of the Standard they represent. Unless otherwise required by the Standard, dimensions, the selection of materials and their application remains the responsibility of the ''Design Authority''.<br><br>The full text of the referenced requirements in the [[ASM Roof Systems Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span> |
|} | |} | ||
+ | |||
<div class="panel panel-success"> | <div class="panel panel-success"> | ||
Line 26: | Line 27: | ||
;(1) Metal flashing underlayment/separation membrane: required for metal flashings installed on wood substrates. | ;(1) Metal flashing underlayment/separation membrane: required for metal flashings installed on wood substrates. | ||
;(2) '''Metal edge flashing''': Installed to manufacturer's printed instructions. | ;(2) '''Metal edge flashing''': Installed to manufacturer's printed instructions. | ||
− | ;(3) [[ | + | ;(3) [[ASM Roof Systems Standard#ASMICE|'''Ice and water protection''']]: One ply of accepted self-adhered modified bituminous membrane. |
:* This application is required only for slopes less than 1:3 (4" in 12"). For slopes 1:3 or greater, see Construction Detail '''ASM 8.1.1 Eave Protection and Underlayment'''. | :* This application is required only for slopes less than 1:3 (4" in 12"). For slopes 1:3 or greater, see Construction Detail '''ASM 8.1.1 Eave Protection and Underlayment'''. | ||
:* Slip sheet not shown for clarity | :* Slip sheet not shown for clarity | ||
Line 33: | Line 34: | ||
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === | ||
− | ;(A) [[ | + | ;(A) [[ASM Roof Systems Standard#ASMDECK|'''Acceptable deck''']] |
</div><!-- COL-6-MD --> | </div><!-- COL-6-MD --> | ||
</div><!-- PANEL BODY --> | </div><!-- PANEL BODY --> | ||
</div><!-- PANEL --> | </div><!-- PANEL --> | ||
+ | '''NOTE''': See the [[ASM Roof Systems Standard | '''Standard''']] for additional requirements. | ||
− | + | <hr> | |
− | < | + | [[ASM Roof System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''ASM Roof System Details'']] |
− | [[ | + | [[Main Page | <i class="fa fa-home fa"></i> Home]] |
− | + | {{Tempate:RPM Page Footer with Copyright and Current Date}} |
Revision as of 14:14, 31 August 2021
Notice to Reader | |
Images used in a Construction Detail are representative and not prescriptive. Nor are they necessarily drawn to scale. Rather, they are provided to visually convey the requirements of the Standard they represent. Unless otherwise required by the Standard, dimensions, the selection of materials and their application remains the responsibility of the Design Authority. The full text of the referenced requirements in the Standard may be read by using the blue hyperlinks |
ASM Details
1 WORK INCLUDED
- (1) Metal flashing underlayment/separation membrane
- required for metal flashings installed on wood substrates.
- (2) Metal edge flashing
- Installed to manufacturer's printed instructions.
- (3) Ice and water protection
- One ply of accepted self-adhered modified bituminous membrane.
- This application is required only for slopes less than 1:3 (4" in 12"). For slopes 1:3 or greater, see Construction Detail ASM 8.1.1 Eave Protection and Underlayment.
- Slip sheet not shown for clarity
2 RELATED WORK BY OTHERS
- (A) Acceptable deck
NOTE: See the Standard for additional requirements.
Back to ASM Roof System Details
© RCABC 2024
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.