Difference between revisions of "ARCHIVED - Duro-Last PVC Membrane"
Difference between revisions of "ARCHIVED - Duro-Last PVC Membrane"
(Created page with "{| class="wikitable" |- | '''Manufacturer''': [http://duro-last.com/ '''Duro-Last'''] ;: ;Accepted for '''''RoofStar Guarantee Program''''': TBA |} :Click below for the '''...") |
m (James Klassen moved page Materials:ARCHIVED - Duro-Last PVC Membrane to ARCHIVED - Duro-Last PVC Membrane) |
||
(9 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
− | | '''Manufacturer''': [http://duro-last.com/ '''Duro-Last'''] | + | | style="background-color: #ffffcc; column-width:100%" | '''Notice to the Reader''': |
+ | |||
+ | The roofing assembly / material information published in the RCABC '''''Roofing Practices Manual''''' and offered below does NOT represent a complete set of the manufacturer’s data or specifications. The preparation of a detailed specification is the responsibility of the design authority. | ||
+ | |} | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | '''Manufacturer''': [http://duro-last.com/ '''Duro-Last Roofing, Inc.'''] | ||
;: | ;: | ||
− | ;Accepted for '''''RoofStar Guarantee Program''''': TBA | + | ;Accepted for '''''RoofStar Guarantee Program''''': Date TBA |
+ | ;: | ||
+ | ;'''Product Summary''': | ||
+ | :'''Roof Assembly''': MECHANICALLY FASTENED MEMBRANE, INSULATED AND UN-INSULATED SYSTEMS | ||
+ | :Slope Limitation: Consult the manufacturer's product Specifications. | ||
+ | :;In-Service Performance Min.: | ||
+ | ::-26°c (-15°F) | ||
+ | :;Temperature of the Membrane: | ||
+ | ::Max.: 46°c (115°F) | ||
+ | |||
+ | |||
+ | :'''Roof Assembly''': ADHERED MEMBRANE, INSULATED AND UNINSULATED SYSTEMS | ||
+ | :Slope Limitation: Consult the manufacturer's product Specifications. | ||
+ | :;In-Service Performance Min.: | ||
+ | ::15°c (50°F) | ||
+ | :;Temperature of the Membrane: | ||
+ | ::Max.: 32°c (90°F) | ||
+ | ;: | ||
+ | ;[[Duro-Last PVC Membrane Installation Guidelines|Installation Guidelines]] | ||
|} | |} | ||
− | :Click below for the '''Technical Data Sheet''' | + | :Click below for the '''Technical Data Sheet''' |
− | <div | + | <div class="col-md-2"> |
− | :[[File:Pdf.png|150 px|link=http:// | + | :[[File:Pdf.png|150 px|link=http://rpm.rcabc.org/images/8/81/Duro-Last_50_Mil_TDS.pdf|'''Technical Data Sheet (45 mil)''']] |
+ | <div style="text-align: center;"> | ||
+ | :1.27 mm (50 mil) Membrane TDS | ||
</div> | </div> | ||
− | + | </div> | |
− | + | <div class="col-md-2"> | |
+ | :[[File:Pdf.png|150 px|link=http://rpm.rcabc.org/images/f/f5/Duro-Last_60_Mil_TDS.pdf|'''Technical Data Sheet (60 mil)''']] | ||
+ | <div style="text-align: center;"> | ||
+ | :1.52 mm (60 mil) Membrane TDS | ||
+ | </div> | ||
+ | </div><div class="col-md-12"> | ||
<hr> | <hr> | ||
Line 19: | Line 50: | ||
[[Main Page|Home]] | [[Main Page|Home]] | ||
+ | </div> |
Latest revision as of 13:59, 9 September 2021
Notice to the Reader:
The roofing assembly / material information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications. The preparation of a detailed specification is the responsibility of the design authority. |
Manufacturer: Duro-Last Roofing, Inc.
|
- Click below for the Technical Data Sheet