Difference between revisions of "ASM Eave Protection and Underlayment (Low Slopes)"
Difference between revisions of "ASM Eave Protection and Underlayment (Low Slopes)"
Line 6: | Line 6: | ||
<big><big>Division D - Construction Details</big></big> | <big><big>Division D - Construction Details</big></big> | ||
<hr> | <hr> | ||
− | <big><big><big><big><big>ASM 8.1.2 | + | <big><big><big><big><big>ASM | Eave Protection and Underlayment (Low Slopes) ([[ASM_Roof_Systems_Standard#8.3.2.4. Underlayment for Slopes Less Than 1:3 | Article 8.3.2.4.]])</big></big></big></big></big> |
− | { | + | {{Template:Construction Details Header}} |
− | |||
− | |||
− | |||
− | |||
Line 31: | Line 27: | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
=== WORK INCLUDED === | === WORK INCLUDED === | ||
− | ;(1) Metal flashing underlayment/separation membrane: | + | ;(1) [[ASM Roof Systems Standard#PART_13 | '''Metal flashing underlayment/separation membrane''']]: Required for metal flashings installed on wood substrates. |
− | ;(2) '''Metal edge flashing''': Installed to manufacturer's printed instructions. | + | ;(2)[[ASM Roof Systems Standard#PART_13 | '''Metal edge flashing''']]: Installed to manufacturer's printed instructions. |
− | ;(3) [[ASM Roof Systems Standard# | + | ;(3) [[ASM Roof Systems Standard#PART_8 |'''Ice and water protection''']]: One ply of accepted self-adhered modified bituminous membrane. |
− | :* This application is required only for slopes less than 1:3 (4" in 12"). For slopes 1:3 or greater, see | + | :* This application is required only for slopes less than 1:3 (4" in 12"). For slopes 1:3 or greater, see '''Eave Protection and Underlayment'''. |
− | :* | + | :* Separation layer not shown for clarity |
<hr> | <hr> | ||
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === | ||
− | ;(A) [[ASM Roof Systems Standard# | + | ;(A) [[ASM Roof Systems Standard#PART_2|'''Acceptable deck''']] |
</div><!-- COL-6-MD --> | </div><!-- COL-6-MD --> | ||
</div><!-- PANEL BODY --> | </div><!-- PANEL BODY --> |
Revision as of 14:53, 28 June 2022
Division D - Construction Details
ASM | Eave Protection and Underlayment (Low Slopes) ( Article 8.3.2.4.)
Notice to Reader | |
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).
The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text. |
ASM Details
1 WORK INCLUDED
- (1) Metal flashing underlayment/separation membrane
- Required for metal flashings installed on wood substrates.
- (2) Metal edge flashing
- Installed to manufacturer's printed instructions.
- (3) Ice and water protection
- One ply of accepted self-adhered modified bituminous membrane.
- This application is required only for slopes less than 1:3 (4" in 12"). For slopes 1:3 or greater, see Eave Protection and Underlayment.
- Separation layer not shown for clarity
2 RELATED WORK BY OTHERS
- (A) Acceptable deck
NOTE: See the Standard for additional requirements.