Difference between revisions of "ASM Eave Protection and Underlayment (Low Slopes)"
Difference between revisions of "ASM Eave Protection and Underlayment (Low Slopes)"
(6 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | { | + | {{Template:RPM Info}} |
− | | | + | |
− | + | {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} | |
+ | __NOTOC__ | ||
+ | |||
+ | <big><big>Division D - Construction Details</big></big> | ||
+ | <hr> | ||
+ | <big><big><big><big><big>ASM | Eave Protection and Underlayment (Low Slopes) ([[ASM_Roof_Systems_Standard#8.3.2.1. Installation of Eave Protection | Article 8.3.2.1.]] and [[ASM_Roof_Systems_Standard#8.3.2.4. Underlayment for Slopes Less Than 1:3 | Article 8.3.2.4.]])</big></big></big></big></big> | ||
+ | {{Template:Construction Details Header}} | ||
+ | |||
+ | |||
<div class="panel panel-success"> | <div class="panel panel-success"> | ||
<div class="panel-heading"><big>'''ASM Details'''</big></div> | <div class="panel-heading"><big>'''ASM Details'''</big></div> | ||
Line 7: | Line 15: | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
<div style="text-align:center; vertical-align:center"> | <div style="text-align:center; vertical-align:center"> | ||
− | [[File:8.1 | + | [[File:ASM 8.1.2 Self-Adhered Underlayment.jpg|class=img-responsive | link=http://rpm.rcabc.org/images/b/bd/ASM_8.1.2_Self-Adhered_Underlayment.jpg]] |
</div> | </div> | ||
− | ::Click below for a printable version of this page | + | ::Click below for a printable version of this page (N/A) |
<div style="width:150px; text-align: left;"> | <div style="width:150px; text-align: left;"> | ||
− | :[[File: | + | :[[File:Pdf.png|100 px|link=|'''Print Sheet''']] |
</div> | </div> | ||
</div><!-- COL-MD-6 --> | </div><!-- COL-MD-6 --> | ||
Line 19: | Line 27: | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
=== WORK INCLUDED === | === WORK INCLUDED === | ||
− | ;(1) [[ | + | ;(1) [[ASM Roof Systems Standard#PART_13 | '''Metal flashing underlayment/separation membrane''']]: Required for metal flashings installed on wood substrates. |
− | ;(2) [[ | + | ;(2)[[ASM Roof Systems Standard#PART_13 | '''Metal edge flashing''']]: Installed to manufacturer's printed instructions. |
− | ;(3) [[ | + | ;(3) [[ASM Roof Systems Standard#PART_8 |'''Ice and water protection''']]: One ply of accepted self-adhered modified bituminous membrane. |
− | + | :* This application is required only for slopes less than 1:3 (4" in 12"). For slopes 1:3 or greater, see '''Eave Protection and Underlayment'''. | |
− | + | :* Separation layer not shown for clarity | |
− | : | ||
<hr> | <hr> | ||
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === | ||
− | ;(A) [[ | + | ;(A) [[ASM Roof Systems Standard#PART_2|'''Acceptable deck''']] |
</div><!-- COL-6-MD --> | </div><!-- COL-6-MD --> | ||
</div><!-- PANEL BODY --> | </div><!-- PANEL BODY --> | ||
</div><!-- PANEL --> | </div><!-- PANEL --> | ||
− | '''NOTE''': | + | '''NOTE''': See the [[ASM Roof Systems Standard | '''Standard''']] for additional requirements. |
<hr> | <hr> | ||
+ | [[ASM Roof System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''ASM Roof System Details'']] | ||
− | [[ | + | [[Main Page | <i class="fa fa-home fa"></i> Home]] |
− | |||
− | |||
− | + | {{Tempate:RPM Page Footer with Copyright and Current Date}} |
Latest revision as of 14:55, 28 June 2022
Division D - Construction Details
ASM | Eave Protection and Underlayment (Low Slopes) ( Article 8.3.2.1. and Article 8.3.2.4.)
Notice to Reader | |
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).
The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text. |
ASM Details
1 WORK INCLUDED
- (1) Metal flashing underlayment/separation membrane
- Required for metal flashings installed on wood substrates.
- (2) Metal edge flashing
- Installed to manufacturer's printed instructions.
- (3) Ice and water protection
- One ply of accepted self-adhered modified bituminous membrane.
- This application is required only for slopes less than 1:3 (4" in 12"). For slopes 1:3 or greater, see Eave Protection and Underlayment.
- Separation layer not shown for clarity
2 RELATED WORK BY OTHERS
- (A) Acceptable deck
NOTE: See the Standard for additional requirements.
Back to ASM Roof System Details
© RCABC 2024
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.