Difference between revisions of "ASM Eave and Rake Edges (Zinc)"

Jump to: navigation, search

Difference between revisions of "ASM Eave and Rake Edges (Zinc)"

Line 6: Line 6:
 
<big><big>Division D - Construction Details</big></big>
 
<big><big>Division D - Construction Details</big></big>
 
<hr>
 
<hr>
<big><big><big><big><big>ASM 10.1.4 Eave and Rake Flashing (Zinc)</big></big></big></big></big>
+
<big><big><big><big><big>ASM | Eave and Rake Edges (Zinc) ([[ASM_Roof_Systems_Standard#10.3.2.3. General Application Requirements for Perimeters and Walls | Article 10.3.2.3.]] and [[ASM_Roof_Systems_Standard#10.3.4.2. Eaves and Rake Edges | Article 10.3.4.2.]])</big></big></big></big></big>
{| class="wikitable" | style="color: black; background-color: orange; width: 100%;text-align:center"
+
{{Template:Construction Details Header}}
| colspan="2"  | <big>'''''Notice to Reader'''''</big>
 
|-
 
| style="color: black; background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive.  Nor are they necessarily drawn to scale. Rather, they are provided to visually convey the requirements of the Standard they represent. Unless otherwise required by the Standard, dimensions, the selection of materials and their application remains the responsibility of the ''Design Authority''.<br><br>The full text of the referenced requirements in the [[ASM Roof Systems Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span>
 
|}
 
  
 
<div class="panel panel-success">
 
<div class="panel panel-success">

Revision as of 16:07, 28 June 2022



Division D - Construction Details


ASM | Eave and Rake Edges (Zinc) ( Article 10.3.2.3. and Article 10.3.4.2.)

Notice to Reader
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).

The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text.

SBS Details

ASM 10.1.4 Eave and Rake Flashing (Zinc).jpg


Click below for a printable version of this page (N/A)
Print Sheet

1 WORK INCLUDED

(1) Separation membrane
Separates the deck and the metal edge flashing.
(2) Hook securement strip
In this particular rake edge configuration, a similar strip is installed along the rake to secure the flush rake-edge flashing.
(3) Continuous eave metal flashing
(4) Eave protection
One ply of self-adhered modified bituminous underlayment material. Lap 50 mm (2") minimum on sides and 100 mm (4") minimum on ends.
(5) Underlayment
Applicable for all Architectural Sheet Metal systems. For slopes less than 1:3, the entire roof slope must be covered with a self-adhered underlayment.
(6) Ventilation material
A ventilation space is required on slopes less than 1:3; entangled mesh (shown) may be used as void fill. The ventilation space facilitates drying as condensation forms on the underside of the metal panels.
(7) Metal panel clip
Installed in keeping with the metal roof panel manufacturer's printed instructions. Install on EPDM pad (not shown) or use a tall clip sized to support the panel on top of the ventilation layer.
(8) Flush rake-edge flashing
Note that panel hooks onto outside edge of flashing, which is mechanically secured to the roof deck.
(9) Architectural metal roof panel

2 RELATED WORK BY OTHERS

(A) Acceptable deck
(B) Fascia Board

NOTE: See the Standard for additional requirements.


Back to ASM Roof System Details