;Product Summary: Carlisle's RapidLock (RL) fleece-backed TPO membrane is internally reinforced and must be installed over their proprietary insulation panels, SecurShield RapidLock Polyiso and SecurShield RapidLock HD Polyiso. Both panels are manufactured with a VELCRO<sup><big>®</big></sup> Brand Securable Solutions facer on the upper side of the panel, to which the membrane is attached. | ;Product Summary: Carlisle's RapidLock (RL) fleece-backed TPO membrane is internally reinforced and must be installed over their proprietary insulation panels, SecurShield RapidLock Polyiso and SecurShield RapidLock HD Polyiso. Both panels are manufactured with a VELCRO<sup><big>®</big></sup> Brand Securable Solutions facer on the upper side of the panel, to which the membrane is attached. | ||
:(adapted from the Technical Data Sheet) | :(adapted from the Technical Data Sheet) | ||
+ | |||
+ | :Available thickness (nominal, over fleece): 1.524 mm (60 mil) / 2.92 mm (115 mil) | ||
;Conditions and Limitations: Carlisle's RapidLock (RL) membranes (EPDM, TPO, and PVC) are accepted by the RGC for use on waterproofing roofs up to 30.48 m (100') above grade (higher roofs require a design review by Carlisle Syntec Systems Canada). | ;Conditions and Limitations: Carlisle's RapidLock (RL) membranes (EPDM, TPO, and PVC) are accepted by the RGC for use on waterproofing roofs up to 30.48 m (100') above grade (higher roofs require a design review by Carlisle Syntec Systems Canada). | ||
+ | :<br><sup>†</sup> Note that the membrane tables classify this as "self-adhered". However, because of the VELCRO<sup><big>®</big></sup> Brand Securable Solutions technology used to secure the membrane, RapidLock membranes do not qualify for traditional self-adhered applications, such as in gutters or ''protected membrane roof assemblies''. | ||
;Technical Data Sheet:Click the "PDF" icon to open the TDS in a new window. | ;Technical Data Sheet:Click the "PDF" icon to open the TDS in a new window. |
Latest revision as of 18:56, 31 October 2023
Division C - Accepted Materials
FleeceBACK RL (RapidLock) TPO
by Carlisle SynTec Systems Canada
Material Acceptance and Product Details
|
|