:Available thickness (nominal): 2.92 mm (115 mil)
+
:Available thickness (nominal, over fleece): 1.524 mm (60 mil) / 2.92 mm (115 mil)
  
 
;Conditions and Limitations: Carlisle's RapidLock (RL) membranes (EPDM, TPO, and PVC) are accepted by the RGC for use on waterproofing roofs up to 30.48 m (100') above grade (higher roofs require a design review by Carlisle Syntec Systems Canada).
 
;Conditions and Limitations: Carlisle's RapidLock (RL) membranes (EPDM, TPO, and PVC) are accepted by the RGC for use on waterproofing roofs up to 30.48 m (100') above grade (higher roofs require a design review by Carlisle Syntec Systems Canada).
 +
:<br><sup>†</sup> Note that the membrane tables classify this as "self-adhered".  However, because of the VELCRO<sup><big>®</big></sup> Brand Securable Solutions technology used to secure the membrane, RapidLock membranes do not qualify for traditional self-adhered applications, such as in gutters or ''protected membrane roof assemblies''.
  
 
;Technical Data Sheet:Click the "PDF" icon to open the TDS in a new window.
 
;Technical Data Sheet:Click the "PDF" icon to open the TDS in a new window.

Latest revision as of 18:56, 31 October 2023



Division C - Accepted Materials


FleeceBACK RL (RapidLock) TPO
by Carlisle SynTec Systems Canada

Material Acceptance and Product Details


The information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications, nor is this material recommended or endorsed by the Guarantor. The preparation of a detailed specification is the responsibility of the Design Authority.

Manufacturer
http://www.carlislesyntec.com
Accepted for the RoofStar Guarantee Program
October 20, 2023
Accepted for application in
Roof Waterproofing Systems
Acceptance Criteria
N/A
Product Summary
Carlisle's RapidLock (RL) fleece-backed TPO membrane is internally reinforced and must be installed over their proprietary insulation panels, SecurShield RapidLock Polyiso and SecurShield RapidLock HD Polyiso. Both panels are manufactured with a VELCRO® Brand Securable Solutions facer on the upper side of the panel, to which the membrane is attached.
(adapted from the Technical Data Sheet)
Available thickness (nominal, over fleece): 1.524 mm (60 mil) / 2.92 mm (115 mil)
Conditions and Limitations
Carlisle's RapidLock (RL) membranes (EPDM, TPO, and PVC) are accepted by the RGC for use on waterproofing roofs up to 30.48 m (100') above grade (higher roofs require a design review by Carlisle Syntec Systems Canada).

Note that the membrane tables classify this as "self-adhered". However, because of the VELCRO® Brand Securable Solutions technology used to secure the membrane, RapidLock membranes do not qualify for traditional self-adhered applications, such as in gutters or protected membrane roof assemblies.
Technical Data Sheet
Click the "PDF" icon to open the TDS in a new window.
Technical Data Sheet

Back to Accepted Materials

Home