Difference between revisions of "ASM Ridge (Unvented, Uninsulated)"
Difference between revisions of "ASM Ridge (Unvented, Uninsulated)"
(→RELATED WORK BY OTHERS) |
|||
Line 1: | Line 1: | ||
− | |||
[[File:8.1.4.11.1.jpg]] | [[File:8.1.4.11.1.jpg]] | ||
=== WORK INCLUDED === | === WORK INCLUDED === | ||
+ | ;(1) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMUNDERLAYMENT|'''Underlayment''']]: The type of underlay required is determined by roof slope (see Section 8.1.4.1 and Section 8.1.4.2). | ||
+ | ;(2) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMSLIP|'''Slip Sheet''']]: Recommended over asphaltic underlays and / or as required by metal roof panel manufacturer. | ||
+ | ;(3) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMPANEL |'''Architectural Metal Roof Panel''']]: Turn up (bread panned) at termination and drag load fastened with compatible non-corrosive fasteners. | ||
+ | ;(4) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMZ |''''Z' Closure''']]: Set in accepted caulking and secured with compatible non-corrosive, flathead fasteners. | ||
+ | :or | ||
+ | ;(5) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMCLOSURE |'''Pre-formed Closure''']]: Set in accepted caulking. | ||
+ | ;(6) '''Metal Cap Flashing''': Joints overlapped 100 mm (4") minimum, sealed with two rows of accepted caulking. Exposed edges must be turned under 12.7 mm (1/2"). Fastened to each standing seam with high domed gasketed cladding screws or hooked to 'Z' closures. | ||
+ | ;(7) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMDRAG |'''Drag-load Fasteners''']]: Compatible non-corrosive fasteners. | ||
− | + | <hr> | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === | ||
+ | ;(A) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMDECK|'''Acceptable Deck''']] | ||
+ | ;(B) '''Wood Nailer''' | ||
− | |||
− | |||
− | |||
− | '''NOTE''': Refer to | + | '''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements. |
− | |||
<hr> | <hr> | ||
Line 36: | Line 26: | ||
+ | [[Section:E. Application: Steep Slope Roofs|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''ASM Application'']] | ||
− | + | [[Architectural Sheet Metal Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''ASM Construction Details'']] | |
− | |||
− | [[Architectural Sheet Metal Construction Details|<i class="fa fa-chevron-circle-left fa | ||
− | [[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa | + | [[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']] |
Revision as of 18:12, 10 August 2016
1 WORK INCLUDED
- (1) Underlayment
- The type of underlay required is determined by roof slope (see Section 8.1.4.1 and Section 8.1.4.2).
- (2) Slip Sheet
- Recommended over asphaltic underlays and / or as required by metal roof panel manufacturer.
- (3) Architectural Metal Roof Panel
- Turn up (bread panned) at termination and drag load fastened with compatible non-corrosive fasteners.
- (4) 'Z' Closure
- Set in accepted caulking and secured with compatible non-corrosive, flathead fasteners.
- or
- (5) Pre-formed Closure
- Set in accepted caulking.
- (6) Metal Cap Flashing
- Joints overlapped 100 mm (4") minimum, sealed with two rows of accepted caulking. Exposed edges must be turned under 12.7 mm (1/2"). Fastened to each standing seam with high domed gasketed cladding screws or hooked to 'Z' closures.
- (7) Drag-load Fasteners
- Compatible non-corrosive fasteners.
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
- (B) Wood Nailer
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.