ASM Ridge (Unvented, Uninsulated)

Jump to: navigation, search

ASM Ridge (Unvented, Uninsulated)



Division D - Construction Details


ASM | Ridge (Unvented, Uninsulated) ( Article 10.3.2.3. and Article 10.3.4.1.)

Notice to Reader
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).

The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text.

SBS Details

ASM 10.4.1 Ridge (Unvented).jpg

Click below for a printable version of this page (N/A)
Print Sheet


1 WORK INCLUDED

(1) Underlayment
The type of underlay required is determined by roof slope.
(2) Ventilation layer
A ventilation space is required on slopes less than 1:3; entangled mesh (shown) may be used as void fill. The ventilation space facilitates drying as condensation forms on the underside of the metal panels.
(3) Architectural metal panel clip
(4) 'Z' Closure
Set in accepted sealant or butyl tape and secured with compatible non-corrosive flathead fasteners.
(5) Sealant
(6) Drag-load fasteners
Compatible non-corrosive fasteners.
(7) Architectural metal roof panel
Top end of panels must be "bread-panned".
(8) Ridge cap flashing
Cut away to reveal 'Z' closure and drag-load fasteners.

2 RELATED WORK BY OTHERS

(A) Acceptable Deck

NOTE: See the Standard for additional requirements.


Back to ASM Roof System Details