{| class="wikitable" | style="color: black; background-color: orange; width: 100%;text-align:center"
+
{{Template:RPM Info}}
| colspan="2| <big>'''''RoofStar Guarantee Standards''''' are <span style="color:#6495ed">'''blue-linked'''</span></big>
+
 
|}
+
{{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}}
 +
__NOTOC__
 +
 
 +
<big><big>Division D - Construction Details</big></big>
 +
<hr>
 +
<big><big><big><big><big>ASM | Eave and Rake Edges (Snap-Lock Seams) ([[ASM_Roof_Systems_Standard#10.3.2.3. General Application Requirements for Perimeters and Walls | Article 10.3.2.3.]] and [[ASM_Roof_Systems_Standard#10.3.4.2. Eaves and Rake Edges | Article 10.3.4.2.]])</big></big></big></big></big>
 +
{{Template:Construction Details Header}}
 
<div class="panel panel-success">
 
<div class="panel panel-success">
 
<div class="panel-heading"><big>'''ASM Details'''</big></div>
 
<div class="panel-heading"><big>'''ASM Details'''</big></div>
Line 7: Line 13:
 
<div class="col-md-6">
 
<div class="col-md-6">
 
<div style="text-align:center; vertical-align:center">
 
<div style="text-align:center; vertical-align:center">
[[File:8.1.4.4.1.jpg|class=img-responsive]]
+
[[File:8.1.4.4.1.jpg| link=http://rpm.rcabc.org/images/1/1c/8.1.4.4.1.jpg | class=img-responsive]]
 
</div>
 
</div>
 
</div><!-- COL-MD-6 -->
 
</div><!-- COL-MD-6 -->
Line 13: Line 19:
 
<div class="col-md-6">
 
<div class="col-md-6">
 
=== WORK INCLUDED ===
 
=== WORK INCLUDED ===
;(1) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMICE|'''Ice and Water Protection''']]: Accepted self-adhered modified bituminous membrane.
+
;(1) [[ASM Roof Systems Standard#8.1.3.1. Eave Protection|'''Eave Protection''']]: Accepted self-adhered modified bituminous membrane.
;(2) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMSLIP|'''Slip Sheet''']]: Recommended over asphaltic underlays and / or as required by metal panel manufacturer.  
+
;(2) [[ASM Roof Systems Standard#8.1.3.4. Separation Between Materials |'''Separation Layer''']]: Recommended over asphaltic underlays and / or as required by metal panel manufacturer.  
;(3) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMCLIP|'''Metal Panel Clip''']]: Installed to metal roof panel manufacturer's printed instructions.  
+
;(3) [[ASM Roof Systems Standard#9.2.1.5.Clips|'''Metal Panel Clip''']]: Installed to metal roof panel manufacturer's printed instructions.  
;(4) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMPANEL |'''Architectural Metal Roof Panel''']]
+
;(4) [[ASM Roof Systems Standard#PART_9 |'''Architectural Metal Roof Panel''']]
 
;(5) '''Continuous Metal Cleat'''
 
;(5) '''Continuous Metal Cleat'''
 
;(6) '''Metal Fascia Flashing'''
 
;(6) '''Metal Fascia Flashing'''
 
;(7) '''Edge Metal Flashing (Continuous)'''
 
;(7) '''Edge Metal Flashing (Continuous)'''
;(8) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMCLOSURE |'''Pre-formed Closures''']]
+
;(8) [[ASM Roof Systems Standard#9.3.2.6. Panel Terminations |'''Pre-formed Closures''']]
;(9) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMEXFASTEN |'''Exposed Fasteners''']]: High-domed gasketed cladding type screws compatible with metal roof panel.  
+
;(9) [[ASM Roof Systems Standard#13.2.1.3. Fasteners |'''Exposed Fasteners''']]: High-domed gasketed cladding type screws compatible with metal roof panel.  
 
;(10) '''Rake Edge Metal Flashing'''
 
;(10) '''Rake Edge Metal Flashing'''
  
Line 27: Line 33:
  
 
=== RELATED WORK BY OTHERS ===
 
=== RELATED WORK BY OTHERS ===
;(A) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMDECK|'''Acceptable Deck''']]
+
;(A) [[ASM Roof Systems Standard#PART_2|'''Acceptable Deck''']]
 
;(B) '''Fascia Board'''  
 
;(B) '''Fascia Board'''  
 
</div><!-- COL-6-MD -->
 
</div><!-- COL-6-MD -->
Line 34: Line 40:
  
  
'''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements.
+
'''NOTE''': See the [[ASM Roof Systems Standard | '''Standard''']] for additional requirements.
 
 
  
 
<hr>
 
<hr>
  
 +
[[ASM Roof System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''ASM Roof System Details'']]
  
 +
[[Main Page | <i class="fa fa-home fa"></i> Home]]
  
[[RoofStar Guarantee Standards for ASM Roof Systems|<i class="fa fa-chevron-circle-left fa" ></i> RoofStar Guarantee Standards for ASM Roof Systems]]
+
{{Tempate:RPM Page Footer with Copyright and Current Date}}
 
 
[[Architectural Sheet Metal Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''ASM Construction Details'']]
 
 
 
[[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']]
 

Latest revision as of 18:04, 28 June 2022



Division D - Construction Details


ASM | Eave and Rake Edges (Snap-Lock Seams) ( Article 10.3.2.3. and Article 10.3.4.2.)

Notice to Reader
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).

The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text.

ASM Details

8.1.4.4.1.jpg

1 WORK INCLUDED

(1) Eave Protection
Accepted self-adhered modified bituminous membrane.
(2) Separation Layer
Recommended over asphaltic underlays and / or as required by metal panel manufacturer.
(3) Metal Panel Clip
Installed to metal roof panel manufacturer's printed instructions.
(4) Architectural Metal Roof Panel
(5) Continuous Metal Cleat
(6) Metal Fascia Flashing
(7) Edge Metal Flashing (Continuous)
(8) Pre-formed Closures
(9) Exposed Fasteners
High-domed gasketed cladding type screws compatible with metal roof panel.
(10) Rake Edge Metal Flashing

2 RELATED WORK BY OTHERS

(A) Acceptable Deck
(B) Fascia Board


NOTE: See the Standard for additional requirements.


Back to ASM Roof System Details

Home

© RCABC 2024
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.