Difference between revisions of "ASM Ridge (Unvented, Insulated)"
Difference between revisions of "ASM Ridge (Unvented, Insulated)"
(12 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | { | + | {{Template:RPM Info}} |
− | | | + | |
− | + | {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} | |
+ | __NOTOC__ | ||
+ | |||
+ | <big><big>Division D - Construction Details</big></big> | ||
+ | <hr> | ||
+ | <big><big><big><big><big>ASM | Ridge (Unvented, Insulated) ([[ASM_Roof_Systems_Standard#10.3.2.3. General Application Requirements for Perimeters and Walls | Article 10.3.2.3.]] and [[ASM_Roof_Systems_Standard#10.3.4.1. Ridges | Article 10.3.4.1.]])</big></big></big></big></big> | ||
+ | {{Template:Construction Details Header}} | ||
<div class="panel panel-success"> | <div class="panel panel-success"> | ||
− | <div class="panel-heading"><big>''' | + | <div class="panel-heading"><big>'''SBS Details'''</big></div> |
<div class="panel-body"> | <div class="panel-body"> | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
<div style="text-align:center; vertical-align:center"> | <div style="text-align:center; vertical-align:center"> | ||
− | [[File:ASM | + | [[File:ASM 10.4.2 Ridge (Unvented, Insulated).jpg|class=img-responsive | link=http://rpm.rcabc.org/images/4/4c/ASM_10.4.2_Ridge_%28Unvented%2C_Insulated%29.jpg]] |
+ | </div> | ||
+ | |||
+ | ::Click below for a printable version of this page (N/A) | ||
+ | |||
+ | <div style="width:150px; text-align: left;"> | ||
+ | :[[File:Pdf.png|100 px|link=http://rpm.rcabc.org/images/5/52/D1.7.6-3_Print_Sheet.pdf|'''Print Sheet''']] | ||
</div> | </div> | ||
+ | |||
+ | |||
</div><!-- COL-MD-6 --> | </div><!-- COL-MD-6 --> | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
=== WORK INCLUDED === | === WORK INCLUDED === | ||
− | ;(1) [[ | + | ;(1) [[ASM Roof Systems Standard#8.1.3.3. Field Underlayment |'''Underlayment''']]: The type of underlay required is determined by roof slope. |
− | ;(2) [[ | + | ;(2) Ridge girts: May be required by engineer for panel drag load fasteners. Secured using compatible non-corrosive fasteners. |
− | ;( | + | ;(3) [[ASM Roof Systems Standard#PART_7|'''Insulation''']]: Offset and stagger layers 300 mm (12"). |
− | ;( | + | ;(4) [[ASM Roof Systems Standard#8.1.3.4. Separation Between Materials |'''Vapour-permeable separation membrane''']]: Installed over insulation and required on all insulated Architectural Sheet Metal Roof Systems. The material must be located between the insulation and metal panels/ventilation material. |
− | + | ;(5) [[ASM Roof Systems Standard#8.1.3.5. Ventilation Beneath Panels |'''Ventilation beneath panels''']]: A ventilation space is required on slopes less than 1:3; entangled mesh (shown) may be used as void fill. The ventilation space facilitates drying as condensation forms on the underside of the metal panels. | |
− | ;( | + | ;(6) [[ASM Roof Systems Standard#PART_9 |'''Architectural metal roof panel''']]: Top end of panels must be "bread-panned". Clips are not illustrated. |
− | ;( | + | ;(7) [[ASM Roof Systems Standard#9.1.3.2. System Securement |'''Drag-load fasteners''']]: Compatible non-corrosive fasteners. |
− | ;( | + | ;(8) [[ASM Roof Systems Standard#PART_10 | '''Foam closures''']]: may be used to close ridge when cap flashing is mechanically attached to the panels ribs. |
+ | ;(9) [[ASM Roof Systems Standard#10.3.4.1. Ridges | '''Ridge cap flashing''']] | ||
+ | ;(10) [[ASM Roof Systems Standard#9.2.1.4.Fasteners | '''Fasteners''']]: | ||
<hr> | <hr> | ||
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === | ||
− | ;(A) [[ | + | ;(A) [[ASM Roof Systems Standard#PART_2|'''Acceptable Deck''']] |
− | |||
</div><!-- COL-6-MD --> | </div><!-- COL-6-MD --> | ||
</div><!-- PANEL BODY --> | </div><!-- PANEL BODY --> | ||
</div><!-- PANEL --> | </div><!-- PANEL --> | ||
− | + | '''NOTE''': See the [[ASM Roof Systems Standard | '''Standard''']] for additional requirements. | |
− | '''NOTE''': | ||
<hr> | <hr> | ||
+ | [[ASM Roof System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''ASM Roof System Details'']] | ||
− | [[ | + | [[Main Page | <i class="fa fa-home fa"></i> Home]] |
− | |||
− | |||
− | + | {{Tempate:RPM Page Footer with Copyright and Current Date}} |
Latest revision as of 18:24, 28 June 2022
Division D - Construction Details
ASM | Ridge (Unvented, Insulated) ( Article 10.3.2.3. and Article 10.3.4.1.)
Notice to Reader | |
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).
The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text. |
SBS Details
1 WORK INCLUDED
- (1) Underlayment
- The type of underlay required is determined by roof slope.
- (2) Ridge girts
- May be required by engineer for panel drag load fasteners. Secured using compatible non-corrosive fasteners.
- (3) Insulation
- Offset and stagger layers 300 mm (12").
- (4) Vapour-permeable separation membrane
- Installed over insulation and required on all insulated Architectural Sheet Metal Roof Systems. The material must be located between the insulation and metal panels/ventilation material.
- (5) Ventilation beneath panels
- A ventilation space is required on slopes less than 1:3; entangled mesh (shown) may be used as void fill. The ventilation space facilitates drying as condensation forms on the underside of the metal panels.
- (6) Architectural metal roof panel
- Top end of panels must be "bread-panned". Clips are not illustrated.
- (7) Drag-load fasteners
- Compatible non-corrosive fasteners.
- (8) Foam closures
- may be used to close ridge when cap flashing is mechanically attached to the panels ribs.
- (9) Ridge cap flashing
- (10) Fasteners
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
NOTE: See the Standard for additional requirements.
Back to ASM Roof System Details
© RCABC 2024
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.