Difference between revisions of "ASM Eave and Rake Edges (Snap-Lock Seams)"
Difference between revisions of "ASM Eave and Rake Edges (Snap-Lock Seams)"
(4 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
{{Template:RPM Info}} | {{Template:RPM Info}} | ||
+ | |||
+ | {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} | ||
+ | __NOTOC__ | ||
+ | |||
+ | <big><big>Division D - Construction Details</big></big> | ||
<hr> | <hr> | ||
− | + | <big><big><big><big><big>ASM | Eave and Rake Edges (Snap-Lock Seams) ([[ASM_Roof_Systems_Standard#10.3.2.3. General Application Requirements for Perimeters and Walls | Article 10.3.2.3.]] and [[ASM_Roof_Systems_Standard#10.3.4.2. Eaves and Rake Edges | Article 10.3.4.2.]])</big></big></big></big></big> | |
− | + | {{Template:Construction Details Header}} | |
− | |- | ||
− | |||
− | |||
<div class="panel panel-success"> | <div class="panel panel-success"> | ||
<div class="panel-heading"><big>'''ASM Details'''</big></div> | <div class="panel-heading"><big>'''ASM Details'''</big></div> | ||
Line 11: | Line 13: | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
<div style="text-align:center; vertical-align:center"> | <div style="text-align:center; vertical-align:center"> | ||
− | [[File:8.1.4.4.1.jpg|class=img-responsive]] | + | [[File:8.1.4.4.1.jpg| link=http://rpm.rcabc.org/images/1/1c/8.1.4.4.1.jpg | class=img-responsive]] |
</div> | </div> | ||
</div><!-- COL-MD-6 --> | </div><!-- COL-MD-6 --> | ||
Line 17: | Line 19: | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
=== WORK INCLUDED === | === WORK INCLUDED === | ||
− | ;(1) [[ASM Roof Systems Standard# | + | ;(1) [[ASM Roof Systems Standard#8.1.3.1. Eave Protection|'''Eave Protection''']]: Accepted self-adhered modified bituminous membrane. |
− | ;(2) [[ASM Roof Systems Standard# | + | ;(2) [[ASM Roof Systems Standard#8.1.3.4. Separation Between Materials |'''Separation Layer''']]: Recommended over asphaltic underlays and / or as required by metal panel manufacturer. |
− | ;(3) [[ASM Roof Systems Standard# | + | ;(3) [[ASM Roof Systems Standard#9.2.1.5.Clips|'''Metal Panel Clip''']]: Installed to metal roof panel manufacturer's printed instructions. |
− | ;(4) [[ASM Roof Systems Standard# | + | ;(4) [[ASM Roof Systems Standard#PART_9 |'''Architectural Metal Roof Panel''']] |
;(5) '''Continuous Metal Cleat''' | ;(5) '''Continuous Metal Cleat''' | ||
;(6) '''Metal Fascia Flashing''' | ;(6) '''Metal Fascia Flashing''' | ||
;(7) '''Edge Metal Flashing (Continuous)''' | ;(7) '''Edge Metal Flashing (Continuous)''' | ||
− | ;(8) [[ASM Roof Systems Standard# | + | ;(8) [[ASM Roof Systems Standard#9.3.2.6. Panel Terminations |'''Pre-formed Closures''']] |
− | ;(9) [[ASM Roof Systems Standard# | + | ;(9) [[ASM Roof Systems Standard#13.2.1.3. Fasteners |'''Exposed Fasteners''']]: High-domed gasketed cladding type screws compatible with metal roof panel. |
;(10) '''Rake Edge Metal Flashing''' | ;(10) '''Rake Edge Metal Flashing''' | ||
Line 31: | Line 33: | ||
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === | ||
− | ;(A) [[ASM Roof Systems Standard# | + | ;(A) [[ASM Roof Systems Standard#PART_2|'''Acceptable Deck''']] |
;(B) '''Fascia Board''' | ;(B) '''Fascia Board''' | ||
</div><!-- COL-6-MD --> | </div><!-- COL-6-MD --> |
Latest revision as of 18:04, 28 June 2022
Division D - Construction Details
ASM | Eave and Rake Edges (Snap-Lock Seams) ( Article 10.3.2.3. and Article 10.3.4.2.)
Notice to Reader | |
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).
The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text. |
ASM Details
1 WORK INCLUDED
- (1) Eave Protection
- Accepted self-adhered modified bituminous membrane.
- (2) Separation Layer
- Recommended over asphaltic underlays and / or as required by metal panel manufacturer.
- (3) Metal Panel Clip
- Installed to metal roof panel manufacturer's printed instructions.
- (4) Architectural Metal Roof Panel
- (5) Continuous Metal Cleat
- (6) Metal Fascia Flashing
- (7) Edge Metal Flashing (Continuous)
- (8) Pre-formed Closures
- (9) Exposed Fasteners
- High-domed gasketed cladding type screws compatible with metal roof panel.
- (10) Rake Edge Metal Flashing
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
- (B) Fascia Board
NOTE: See the Standard for additional requirements.
Back to ASM Roof System Details
© RCABC 2024
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.