Difference between revisions of "ASM Eave and Rake Edges (Snap-Lock Seams)"
Difference between revisions of "ASM Eave and Rake Edges (Snap-Lock Seams)"
m (James Klassen moved page ASM 10.1.2 Eave and Rake Flashing (Snap Seam) to ASM Eave and Rake Edges (Snap-Lock Seams)) |
|
(No difference)
|
Revision as of 16:04, 28 June 2022
Division D - Construction Details
ASM | Eave and Rake Edges (Snap-Lock Seams) ( Article 10.3.2.3. and Article 10.3.4.2.)
Notice to Reader | |
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).
The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text. |
ASM Details
1 WORK INCLUDED
- (1) Ice and Water Protection
- Accepted self-adhered modified bituminous membrane.
- (2) Slip Sheet
- Recommended over asphaltic underlays and / or as required by metal panel manufacturer.
- (3) Metal Panel Clip
- Installed to metal roof panel manufacturer's printed instructions.
- (4) Architectural Metal Roof Panel
- (5) Continuous Metal Cleat
- (6) Metal Fascia Flashing
- (7) Edge Metal Flashing (Continuous)
- (8) Pre-formed Closures
- (9) Exposed Fasteners
- High-domed gasketed cladding type screws compatible with metal roof panel.
- (10) Rake Edge Metal Flashing
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
- (B) Fascia Board
NOTE: See the Standard for additional requirements.
Back to ASM Roof System Details
© RCABC 2024
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.