Difference between revisions of "Table Drafts 6"

Jump to: navigation, search

Difference between revisions of "Table Drafts 6"

(Blanked the page)
(Tag: Blanking)
 
Line 1: Line 1:
 +
====9.1.3.3. Panel Seams====
  
 +
<ol>
 +
<li>Panel seam heights, which must accommodate the increased potential for water ingress as roof slope diminishes, shall conform to '''Table 9.1.3.3.-A'''.
 +
</li></ol>
 +
<br>
 +
::::::::::{|
 +
|-
 +
| colspan="1"; style="text-align:center;width:450px;" | {{hilite | '''Table 9.1.3.3.-A<br>Minimum Requirements for Seam Types and Heights'''<br>Forming Part of Article 9.1.3.3. || 2027-June-11 }}
 +
|-
 +
|}
 +
:{|  class="wikitable" style="margin-left: 20pt; margin-right: auto;border-color:#E7E9E9;vertical-align:top;text-align:center;" 
 +
|-
 +
! Conditions<br>(see also Part 2 and Article 9.1.3.1.) !! Seam Height Minimums !! Permissible Seam Types
 +
|-
 +
| rowspan="1" style="vertical-align:centre;text-align:center;"  | {{hilite | > 1:3 (4" in 12") || 2027-June-11 }} || 25.4 mm (1") || All
 +
|-
 +
| rowspan="1" style="vertical-align:centre;text-align:center;"  | {{hilite | ≥ 1:4 (3" in 12") || 2027-June-11 }} || 38.1 mm ( 1-1/2”) || {{hilite | Mechanical Lock,  Snap Lock, Snap Cap || 2027-June-11 }}
 +
|-
 +
|  rowspan="1" style="vertical-align:centre;text-align:center;"  | {{hilite | 1:6 (2" in 12") to ≤ 1:3 (4" in 12") || 2027-June-11 }} || 38.1 mm ( 1-1/2”) || Mechanical Lock only (single or double)
 +
|-
 +
|  rowspan="2" style="vertical-align:centre;text-align:center;"  | Less than 1:6 (2” in 12”)<br>(reviewed by RGC prior to tender) || 50.8 mm (2”) + butyl sealant in seam || Mechanical Lock only (single or double)
 +
|-
 +
| 50.8 mm (2”) || Mechanical Lock  only (double)
 +
|-
 +
|  rowspan="1" style="vertical-align:centre;text-align:center;"  | Power-curved panels<br>(reviewed by RGC prior to tender) || 38.1 mm (1-1/2”) + butyl sealant in seam || Mechanical Lock only (single or double)
 +
|-
 +
|-
 +
|  rowspan="1" style="vertical-align:centre;text-align:center;"  | Locations with High Snow Loads<br>(defined in Article 1.1.3.3.) || 50.8 mm (2”) + butyl sealant in seam|| Mechanical Lock only (double)
 +
|}

Revision as of 14:56, 23 June 2026

9.1.3.3. Panel Seams

  1. Panel seam heights, which must accommodate the increased potential for water ingress as roof slope diminishes, shall conform to Table 9.1.3.3.-A.


Table 9.1.3.3.-A
Minimum Requirements for Seam Types and Heights

Forming Part of Article 9.1.3.3.
Conditions
(see also Part 2 and Article 9.1.3.1.)
Seam Height Minimums Permissible Seam Types
> 1:3 (4" in 12") 25.4 mm (1") All
≥ 1:4 (3" in 12") 38.1 mm ( 1-1/2”) Mechanical Lock, Snap Lock, Snap Cap
1:6 (2" in 12") to ≤ 1:3 (4" in 12") 38.1 mm ( 1-1/2”) Mechanical Lock only (single or double)
Less than 1:6 (2” in 12”)
(reviewed by RGC prior to tender)
50.8 mm (2”) + butyl sealant in seam Mechanical Lock only (single or double)
50.8 mm (2”) Mechanical Lock only (double)
Power-curved panels
(reviewed by RGC prior to tender)
38.1 mm (1-1/2”) + butyl sealant in seam Mechanical Lock only (single or double)
Locations with High Snow Loads
(defined in Article 1.1.3.3.)
50.8 mm (2”) + butyl sealant in seam Mechanical Lock only (double)