Difference between revisions of "Materials:Securtorch"
Difference between revisions of "Materials:Securtorch"
(Created page with "{| class="wikitable" |- | style="background-color: #ffffcc; column-width:100%" | '''Notice to the Reader''': The roofing assembly / material information published in the RCA...") |
|||
Line 11: | Line 11: | ||
;Accepted for '''''RoofStar Guarantee Program''''': Date TBA | ;Accepted for '''''RoofStar Guarantee Program''''': Date TBA | ||
;: | ;: | ||
− | ;'''Product Summary''': | + | ;'''Product Summary''': Securtorch is a safe and unique fireboard roofing insulation coated with a thick layer of asphalt covered with a thermofusible protective layer. Its core has been thoroughly treated to provide Class A fire resistance. |
+ | |||
+ | :<table border=0 cellpadding=5 cellspacing=0> | ||
+ | <tr> | ||
+ | <td>Thermal Resistance</td> | ||
+ | <td colspan=2>RSI value = 0.27 / 12.5 mm (1/2") [R Value = 1.5 / 25 mm (1")]</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Standard sizes</td> | ||
+ | <td>Panel size:</td> | ||
+ | <td>1.22 m x 1.22 m (4’ x 4’)</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td></td> | ||
+ | <td>With thickness of:</td> | ||
+ | <td>12.5 mm (1/2")</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Coverage</td> | ||
+ | <td>16 ft²</td> | ||
+ | <td></td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | |||
+ | <table border="1" cellspacing="0" cellpadding="0"> | ||
+ | <tr> | ||
+ | <td valign="top"><strong>Properties</strong></td> | ||
+ | <td valign="top"><strong>Standards</strong></td> | ||
+ | <td valign="top"><strong>Results</strong></td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td valign="top">Density (specific mass)</td> | ||
+ | <td valign="top">ASTM D-1037</td> | ||
+ | <td valign="top">14.5 lb / ft<sup>3</sup> (232 kg / m<sup>3</sup></td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td valign="top">Transverse load</td> | ||
+ | <td valign="top">ASTM C-209</td> | ||
+ | <td valign="top">10.6 lb (47N)</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td valign="top">Tensile strength perpendicular to surface</td> | ||
+ | <td valign="top">ASTM C-209</td> | ||
+ | <td valign="top">761 lb / ft<sup>2</sup> (min)<br> | ||
+ | 36.5 kPa (min)</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td valign="top">Water absorption</td> | ||
+ | <td valign="top">ASTM C-209</td> | ||
+ | <td valign="top">3.5%</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td valign="top">Linear expansion</td> | ||
+ | <td valign="top">ASTM C-209</td> | ||
+ | <td valign="top">0.10%</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td valign="top">Resistance to compression <br> | ||
+ | (10% deformation)</td> | ||
+ | <td valign="top">ASTM C-165</td> | ||
+ | <td valign="top">45 lb / in<sup>2</sup> (min)</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td valign="top">Resistance to compression<br> | ||
+ | (25% deformation)</td> | ||
+ | <td valign="top">ASTM C-165</td> | ||
+ | <td valign="top">80 lb / in<sup>2</sup> (min)</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td valign="top">R-factor (1/2 inch)</td> | ||
+ | <td valign="top">ASTM C-518</td> | ||
+ | <td valign="top">1.5</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td valign="top">Flame spread</td> | ||
+ | <td valign="top">ULC-S-102<br> | ||
+ | ULC - S - 102.2</td> | ||
+ | <td valign="top">15<br> | ||
+ | 20</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td valign="top">Smoke development</td> | ||
+ | <td valign="top">ULC-S-12</td> | ||
+ | <td valign="top">15</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td valign="top">Dimensions</td><td colspan="2">1.22 m x 1.22m (4' x 4' sheets)</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td valign="top">Thickness</td><td colspan="2">12.5 mm (½") </td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td valign="top">Standards</td><td colspan="2">CAN / CSA - A247-M86 and ULC</td> | ||
+ | </tr> | ||
+ | <tr><td colspan=3>Note: tests conducted without the asphalt layer.</td></tr> | ||
+ | </table> | ||
|} | |} | ||
Latest revision as of 22:23, 3 November 2016
Notice to the Reader:
The roofing assembly / material information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications. The preparation of a detailed specification is the responsibility of the design authority. |
Manufacturer: Western Louiseville Fibreboard Inc.
|
- Click below for the Technical Data Sheet (TBA).