Difference between revisions of "SBS Roof System Details"
Difference between revisions of "SBS Roof System Details"
Line 6: | Line 6: | ||
:[[File:RTU Curb.jpg|300 px]] | :[[File:RTU Curb.jpg|300 px]] | ||
</div> | </div> | ||
− | '''NOTE''': 'PDF' shown after a file name below indicates a downloadable print sheet for Construction Details. Click on the detail link | + | <div class="col-md-12"> |
+ | <div style="width:40px; vertical-align: center; text-align: left;"> | ||
+ | [[File:Pdf.png|40 px]] | ||
+ | </div> | ||
+ | '''NOTE''': 'PDF' shown after a file name below indicates a downloadable print sheet is available for Construction Details. Click on the detail link and look for the icon. | ||
+ | </div> | ||
<div class="col-md-6"> | <div class="col-md-6"> |
Revision as of 19:29, 13 January 2017
The drawings contained within this section are intended to represent a variety of modified bituminous roof system applications while remaining generic with regards to manufacturers’ specific application specifications. They do not represent all possible manufacturer application roof system designs. Consult manufacturers’ specifications and RoofStar Guarantee Standards to develop a system acceptable to both the manufacturer and RGC.
For further information about SBS membrane system design and requirements, see SBS Roof Systems.
NOTE: 'PDF' shown after a file name below indicates a downloadable print sheet is available for Construction Details. Click on the detail link and look for the icon.
- D1.7.2-1 Parapets & Copings (Low Parapet - Wall Supported) PDF
- D1.7.2-2 Parapets & Copings (Low Parapet - Unsupported by Wall) PDF
- D1.7.2-3 Parapets & Copings (High Parapet - Wall Supported) PDF
- D1.7.2-4 Parapets & Copings (Parapet - Wall Transition) PDF
- D1.7.4-1 Counter-flashings & Reglets (Deck - Wall Supported) PDF
- D1.7.4-2 Counter-flashings & Reglets (Deck - Unsupported by Wall) PDF
- D1.7.4-3 Counter-flashings & Reglets (Stucco Wall: Re-roofing)
- D1.7.4-4 Counter-flashings & Reglets (Stucco Wall: New)(Under Construction)
- D1.7.4-5 Counter-flashings & Reglets (Double Surface Reglet)
- D1.7.4-6 Counter-flashings & Reglets (Low Door Sill)
- D1.7.4-7 Counter-flashings & Reglets (Window Curb)
- D1.7.5-1 Roof-Wall Transitions (Expansion Joint)
- D1.7.5-2 Roof-Wall Transitions (Divider/Control Joint)
- D1.7.5-3 Roof-Wall Transitions (Fire Separation Joint)
- D1.7.5-4 Roof-Wall Transitions (Fire Separation Wall)
- D1.7.6-1 Curbs & Sleepers (Equipment Sleeper)
- D1.7.6-2 Curbs & Sleepers (Multiple Roof Penetrations)
- D1.7.6-3 Curbs & Sleepers (Basic Curb) PDF
- D1.7.6-4 Curbs & Sleepers (Mechanical Opening) PDF
- D1.7.6-5 Curbs & Sleepers (Pre-curb for Planters) PDF
- D1.7.7-1 Strip-in Flashings (Metal Plumbing)
- D1.7.7-2 Strip-in Flashings (Two-part Cable) PDF
- D1.7.7-3 Strip-in Flashings (Gum Pan/Pitch Pocket)