|+ Click on a manufacturer's name to see the full list of their products accepted for use in the RoofStar Guarantee Program
+
|+ CHow to use the table:
 +
 
 +
#Expand the table for the membrane type and look for maximum <u>wind uplift values that exceed</u> the requirements determined through the RCI calculator;<p>('''NOTE''': while the reports show two different values for tested maximum assembly strength, the RPM tables display only the values adjusted for the required safety factor of 1.5)</p>
 +
#Open the report for the tested assembly that fits with the design parameters you have chosen and calculated, and examine the report.  It will break down the assembly by its components.  Ensure all the key components (Secondary materials, such as deck overlay, insulation and insulation overlay) are accepted by the '''''RoofStar Guarantee Program''''' (note that fasteners and adhesives currently are not listed in this Manual - use the materials specified in the wind test report, or consult the membrane manufacturer);
 +
#In cases where a tested Secondary material is not accepted by the '''''RoofStar Guarantee Program''''', look for alternates which often are published in the each report.  In the absence of published alternates, locate a possible alternate in the [http://rpm.rcabc.org/index.php?title=Materials_by_Product_Type '''Accepted Materials'''] section of this Manual.  If you are unsure about compatibility, contact the [mailto:guarantees@rcabc.org '''RCABC'''].
 
! style="vertical-align:top;" | Manufacturer
 
! style="vertical-align:top;" | Manufacturer
 
! style="vertical-align:top;" | Product Name
 
! style="vertical-align:top;" | Product Name

Revision as of 18:54, 18 July 2017

CHow to use the table:
  1. Expand the table for the membrane type and look for maximum wind uplift values that exceed the requirements determined through the RCI calculator;

    (NOTE: while the reports show two different values for tested maximum assembly strength, the RPM tables display only the values adjusted for the required safety factor of 1.5)

  2. Open the report for the tested assembly that fits with the design parameters you have chosen and calculated, and examine the report. It will break down the assembly by its components. Ensure all the key components (Secondary materials, such as deck overlay, insulation and insulation overlay) are accepted by the RoofStar Guarantee Program (note that fasteners and adhesives currently are not listed in this Manual - use the materials specified in the wind test report, or consult the membrane manufacturer);
  3. In cases where a tested Secondary material is not accepted by the RoofStar Guarantee Program, look for alternates which often are published in the each report. In the absence of published alternates, locate a possible alternate in the Accepted Materials section of this Manual. If you are unsure about compatibility, contact the RCABC.
Manufacturer Product Name Number of Tested Systems
(per report)
kPa (Low) kPa (High) Psf (Low) Psf (High) Deck Type Downloadable Test Report Test Facility Test Facility Report No.
Firestone Building Products Rubbergard EPDM Membrane 1 Tested System
1 Tested System
----
----
-2.90
-3.70
----
----
-60.00
-67.00
Steel MARS Test Report 1
MARS Test Report 2
exp. Service Inc. PUB-DRU283221
PUB-DRU303359
Firestone Building Products Rubbergard ECO White EPDM Membrane 1 Tested System
1 Tested System
----
----
-2.90
-3.70
----
----
-60.00
-67.00
Steel MARS Test Report 1
MARS Test Report 2
exp. Service Inc. PUB-DRU283221
PUB-DRU303359