1 Part 9: Single-ply Table (10-year Guarantee)
Exposed Roof Systems | Protected Roof Systems | Grade-level Water- proofing | |||||||
---|---|---|---|---|---|---|---|---|---|
Conventionally Insulated / Uninsulated Systems | Built-in Gutters |
Ballasted | PMR Systems | ||||||
Mechanically Fastened* |
Self-adhered | Adhered | Adhesive- applied or Self-adhered |
Loose-laid | Self-adhered, Adhesive- applied or Hot-mopped |
Self-adhered, Adhesive- applied or Hot-mopped | |||
Adhesive- applied or Hot-mopped (Smooth) |
Adhesive- applied or Hot-mopped (Fleece-backed) | ||||||||
Type, Reinforcement, Grade | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | |
EPDM (reinforced) | 1.524 (60) | 1.524 (60) | 1.143 (45) | 1.524 (60) | 1.143 (45) | 1.143 (45) | |||
EPDM (unreinforced) | 1.524 (60) | 1.143 (45) | 2.794 (110) | 1.524 (60) | 1.143 (45) | 1.143 (45) | |||
TPO | 1.143 (45) | 1.524 (60) | 1.143 (45) | 2.794 (110) | 1.524 (60) | 1.143 (45) | 1.143 (45) | ||
PVC | 1.270 (50) | 1.270 (50) | 2.667 (105) | 1.524 (60) | 1.270 (50) | 1.270 (50) | 1.524 (60) |
- *Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.
2 Part 9: Single-ply Table (10-year Guarantee)
Exposed Roof Systems | Protected Roof Systems | Grade-level Water- proofing | |||||||
---|---|---|---|---|---|---|---|---|---|
Conventionally Insulated / Uninsulated Systems | Built-in Gutters |
Ballasted | PMR Systems | ||||||
Mechanically Fastened* |
Self-adhered | Adhered | Adhesive- applied or Self-adhered |
Loose-laid | Self-adhered, Adhesive- applied or Hot-mopped |
Self-adhered, Adhesive- applied or Hot-mopped | |||
Adhesive- applied or Hot-mopped (Smooth) |
Adhesive- applied or Hot-mopped (Fleece-backed) | ||||||||
Type, Reinforcement, Grade | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | |
EPDM (reinforced) | 1.524 (60) | 1.524 (60) | 1.143 (45) | 1.524 (60) | 1.143 (45) | 1.143 (45) | |||
EPDM (unreinforced) | 1.524 (60) | 1.143 (45) | 2.794 (110) | 1.524 (60) | 1.143 (45) | 1.143 (45) | |||
TPO | 1.143 (45) | 1.524 (60) | 1.143 (45) | 2.794 (110) | 1.524 (60) | 1.143 (45) | 1.143 (45) | ||
PVC | 1.270 (50) | 1.270 (50) | 2.667 (105) | 1.524 (60) | 1.270 (50) | 1.270 (50) | 1.524 (60) |
- *Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.
3 Part 9: Single-ply Table (15-year Guarantee)
Exposed Roof Systems | Protected Roof Systems | Grade-level Water- proofing | |||||||
---|---|---|---|---|---|---|---|---|---|
Conventionally Insulated / Uninsulated Systems | Built-in Gutters |
Ballasted | PMR Systems | ||||||
Mechanically Fastened* |
Self-adhered | Adhered | Adhesive- applied or Self-adhered |
Loose-laid | Self-adhered, Adhesive- applied or Hot-mopped |
Self-adhered, Adhesive- applied or Hot-mopped | |||
Adhesive- applied or Hot-mopped (Smooth) |
Adhesive- applied or Hot-mopped (Fleece-backed) | ||||||||
Type, Reinforcement, Grade | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | |
EPDM (reinforced) | 1.524 (60) | 1.524 (60) | 1.524 (60) | 2.032 (80) | 1.524 (60) | ||||
EPDM (unreinforced) | 1.524 (60) | 1.524 (60) | 2.790 (110) | 2.032 (80) | 1.524 (60) | ||||
TPO | 1.524 (60) | 1.524 (60) | 1.524 (60) | 2.790 (110) | 2.286 (90) | 1.524 (60) | |||
PVC | 1.524 (60) | 1.524 (60) | 2.667 (105) | 2.286 (90) | 1.524 (60) |