Difference between revisions of "Table Drafts 4"
Difference between revisions of "Table Drafts 4"
(→Part 9: TPO Table (Combined 5, 10, 15)) |
(→Part 9: PVC Table (Combined 5, 10, 15)) |
||
Line 133: | Line 133: | ||
| rowspan="4" style="text-align:left;background-color:#6495ED" | <span style="color:#fff">PVC</span> | | rowspan="4" style="text-align:left;background-color:#6495ED" | <span style="color:#fff">PVC</span> | ||
|- | |- | ||
− | | rowspan="1" style="text-align:center;background-color:#FF0000 " | <span style="color:#fff">5</span> || rowspan="1" style="text-align:center;width=200px;" | | + | | rowspan="1" style="text-align:center;background-color:#FF0000 " | <span style="color:#fff">5</span> || rowspan="1" style="text-align:center;width=200px;" | 1.270 (50) || rowspan="1" style="text-align:center;width=200px;" | <i class="fa fa-times"></i> || rowspan="1" style="text-align:center;width=200px;" | 1.270 (50) || rowspan="1" style="text-align:center;width=200px;" | 1.524 (60) || rowspan="1" style="text-align:center;width=200px;" | 1.270 (50) || rowspan="1" style="text-align:center;width=200px;" | 1.270 (50) || rowspan="1" style="text-align:center;width=200px;" | 1.524 (60) |
|- | |- | ||
− | | rowspan="1" style="text-align:center;background-color:#B22222 " | <span style="color:#fff"> 10</span> || rowspan="1" style="text-align:center;width=200px;" | | + | | rowspan="1" style="text-align:center;background-color:#B22222 " | <span style="color:#fff"> 10</span> || rowspan="1" style="text-align:center;width=200px;" | 1.524 (60) || rowspan="1" style="text-align:center;width=200px;" | <i class="fa fa-times"></i> || rowspan="1" style="text-align:center;width=200px;" | 1.524 (60) || rowspan="1" style="text-align:center;width=200px;" | 1.524 (60) || rowspan="1" style="text-align:center;width=200px;" | 1.524 (60) || rowspan="1" style="text-align:center;width=200px;" | 1.524 (60) || rowspan="1" style="text-align:center;width=200px;" | 1.524 (60) |
|- | |- | ||
− | | rowspan="1" style="text-align:center;background-color:#8B0000 " | <span style="color:#fff"> 15</span> || rowspan="1" style="text-align:center;width=200px;" | | + | | rowspan="1" style="text-align:center;background-color:#8B0000 " | <span style="color:#fff"> 15</span> || rowspan="1" style="text-align:center;width=200px;" | 2.032 (80) || rowspan="1" style="text-align:center;width=200px;" | <i class="fa fa-times"></i> || rowspan="1" style="text-align:center;width=200px;" | 2.032 (80) || rowspan="1" style="text-align:center;width=200px;" | 2.032 (80) || rowspan="1" style="text-align:center;width=200px;" | <i class="fa fa-times"></i> || rowspan="1" style="text-align:center;width=200px;" | 2.032 (80) || rowspan="1" style="text-align:center;width=200px;" | <i class="fa fa-times"></i> |
|- | |- | ||
|} | |} | ||
:<small>*Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.</small> | :<small>*Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.</small> |
Revision as of 21:52, 11 December 2020
1 Part 9: EPDM Table (Combined 5, 10, 15)
Exposed Roof Systems | Protected Roof Systems | Grade-level Water- proofing | |||||||
---|---|---|---|---|---|---|---|---|---|
Conventionally Insulated / Uninsulated Systems | Built-in Gutters |
Ballasted | PMR Systems | ||||||
Mechanically Fastened or Induction Welded* |
Self-adhered | Adhered or Hot-mopped |
Adhered or Self-adhered |
Loose-laid | Self-adhered, Adhered or Hot-mopped |
Self-adhered, Adhered or Hot-mopped | |||
Type, Reinforcement, Grade | Guarantee Term | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | |
EPDM (reinforced) | |||||||||
5 | 1.524 (60) | 1.524 (60) | 1.143 (45) | 1.524 (60) | 1.143 (45) | 1.143 (45) | |||
10 | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | |||
15 | 2.286 (90) | 1.524 (60) | |||||||
EPDM (unreinforced) | |||||||||
5 | 1.524 (60) | 1.143 (45) | 1.524 (60) | 1.143 (45) | 1.143 (45) | ||||
10 | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | ||||
15 | 2.286 (90) | 2.286 (90) | 2.286 (90) |
- *Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.
2 Part 9: TPO Table (Combined 5, 10, 15)
Exposed Roof Systems | Protected Roof Systems | Grade-level Water- proofing | |||||||
---|---|---|---|---|---|---|---|---|---|
Conventionally Insulated / Uninsulated Systems | Built-in Gutters |
Ballasted | PMR Systems | ||||||
Mechanically Fastened or Induction Welded* |
Self-adhered | Adhered or Hot-mopped |
Adhered or Self-adhered |
Loose-laid | Self-adhered, Adhered or Hot-mopped |
Self-adhered, Adhered or Hot-mopped | |||
Type, Reinforcement, Grade | Guarantee Term | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | |
TPO | |||||||||
5 | 1.143 (45) | 1.524 (60) | 1.143 (45) | 1.524 (60) | 1.143 (45) | 1.143 (45) | |||
10 | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | |||
15 | 2.032 (80) | 2.032 (80) | 2.032 (80) | 2.032 (80) |
- *Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.
3 Part 9: PVC Table (Combined 5, 10, 15)
Exposed Roof Systems | Protected Roof Systems | Grade-level Water- proofing | |||||||
---|---|---|---|---|---|---|---|---|---|
Conventionally Insulated / Uninsulated Systems | Built-in Gutters |
Ballasted | PMR Systems | ||||||
Mechanically Fastened or Induction Welded* |
Self-adhered | Adhered or Hot-mopped |
Adhered or Self-adhered |
Loose-laid | Self-adhered, Adhered or Hot-mopped |
Self-adhered, Adhered or Hot-mopped | |||
Type, Reinforcement, Grade | Guarantee Term | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | |
PVC | |||||||||
5 | 1.270 (50) | 1.270 (50) | 1.524 (60) | 1.270 (50) | 1.270 (50) | 1.524 (60) | |||
10 | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | |||
15 | 2.032 (80) | 2.032 (80) | 2.032 (80) | 2.032 (80) |
- *Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.