Difference between revisions of "Table Drafts 6"

Jump to: navigation, search

Difference between revisions of "Table Drafts 6"

Line 50: Line 50:
 
====Semi-intensive Systems====
 
====Semi-intensive Systems====
 
*[[Materials:ZinCo Semi-Intensive Perennial Garden Assembly (Inverted) | ZinCo Semi-Intensive Perennial Garden Assembly (Inverted*)]]
 
*[[Materials:ZinCo Semi-Intensive Perennial Garden Assembly (Inverted) | ZinCo Semi-Intensive Perennial Garden Assembly (Inverted*)]]
 +
<br>
 +
*[[Materials:ZinCo Semi-Intensive Perennial Garden Assembly | ZinCo Semi-Intensive Perennial Garden Assembly<sup>**</sup>]]
  
 
</div>
 
</div>
Line 58: Line 60:
 
====Intensive Systems====
 
====Intensive Systems====
 
*[[Materials:ZinCo Roof Garden Assembly (Inverted) | ZinCo Roof Garden Assembly (Inverted*)]]
 
*[[Materials:ZinCo Roof Garden Assembly (Inverted) | ZinCo Roof Garden Assembly (Inverted*)]]
 +
<br>
 +
*[[Materials:ZinCo Roof Garden Assembly | ZinCo Roof Garden Assembly<sup>**</sup>]]
  
 
</div>
 
</div>
Line 80: Line 84:
 
</div>
 
</div>
 
</div>
 
</div>
 +
<div class="col-md-12">
 +
<hr>
 
:<sup>*</sup> System is designed for a ''protected membrane roof assembly'', also known as an inverted roof assembly.
 
:<sup>*</sup> System is designed for a ''protected membrane roof assembly'', also known as an inverted roof assembly.
 +
:<sup>**</sup> While ''Semi-intensive'', ''Intensive'', and Hybrid (blue-green) ''vegetated roof systems'' are permitted only on ''protected membrane roofs'' (also called "inverted roof assemblies"; see the [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentence 1.1.3.2.(5)] in the "RGC Standard for Vegetated Roofs"), some ''vegetated roof system'' manufacturers offer their systems for ''conventionally insulated roofs'' (these systems are accepted by the RGC and listed here but are non-conforming to the RGC Standard).  Consult the system manufacturer for a re-design of the system for use on a ''protected membrane roof'', or submit a request to the RGC for a written Variance to permit the system on a ''conventionally insulated roof assembly'' following the requirements in [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.6._Variances Article 1.1.3.6.].
 +
</div>
 
</tab>
 
</tab>
 
</tabs>
 
</tabs>
  
 
<div class="col-md-12">
 
<div class="col-md-12">
 
  
 
<hr>
 
<hr>

Revision as of 15:34, 3 December 2024



Division C - Accepted Materials


ZinCo Canada Inc.
Affiliate Member (Accepted Manufacturer of Vegetated Roof Systems)

Systems/Materials Listed by Category under Tabs Above


The information published in the RCABC Roofing Practices Manual and offered under each tab does NOT represent a complete set of the manufacturer’s data or specifications, nor is any listed system or material recommended or endorsed by the Guarantor. The preparation of a detailed specification is the responsibility of the Design Authority.

Affiliate Member: ZinCo Canada Inc.
Website
https://www.zinco.ca/
Contact Address & Services
See the current Membership list, contact information and list of services at www.rcabc.org
System/Materials Acceptance
Pursuant to RCABC policy, this Affiliate Member of the RCABC is accepted as a manufacturer of vegetated roof systems, expressly for use in a roof assembly intended to qualify for a RoofStar Vegetated Roof Guarantee. For more about the Guarantee, see Division A of the RPM, and consult the Standard for Vegetated Roofs.

* System is designed for a protected membrane roof assembly, also known as an inverted roof assembly.
** While Semi-intensive, Intensive, and Hybrid (blue-green) vegetated roof systems are permitted only on protected membrane roofs (also called "inverted roof assemblies"; see the Sentence 1.1.3.2.(5) in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for conventionally insulated roofs (these systems are accepted by the RGC and listed here but are non-conforming to the RGC Standard). Consult the system manufacturer for a re-design of the system for use on a protected membrane roof, or submit a request to the RGC for a written Variance to permit the system on a conventionally insulated roof assembly following the requirements in Article 1.1.3.6..

Home

© RCABC 2024
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.