Difference between revisions of "WP Details:F1.7.5 (Expansion Joint - Deck Level)"

Jump to: navigation, search

Difference between revisions of "WP Details:F1.7.5 (Expansion Joint - Deck Level)"

(WORK INCLUDED)
Line 1: Line 1:
<hr>
+
{| class="wikitable" | style="color: black; background-color: orange; width: 100%;text-align:center"
[[File:9.6.5.jpg]]
+
| colspan="2"  | <big>'''''RoofStar Guarantee Standards''''' are <span style="color:#6495ed">'''blue-linked'''</span></big>
 
+
|}
 +
<div class="panel panel-success">
 +
<div class="panel-heading"><big>'''Waterproofing Details for Plazas, Promenades and Terraces'''</big></div>
 +
<div class="panel-body">
 +
<div class="col-md-6">
 +
<div style="text-align:center; vertical-align:center">
 +
[[File:F1.7.5.jpg|class=img-responsive]]
 +
</div>
 +
</div><!-- COL-MD-6 -->
  
 +
<div class="col-md-6">
 
=== WORK INCLUDED ===
 
=== WORK INCLUDED ===
  
(1)<b> Primary Waterproofing Membrane: </b>Fully adhered<b> </b>to acceptable substrates (concrete slab depicted)<b> </b>install as per <i>RGC Guarantee Standards E </i>and Membrane Manufacturer's installation specifications.  
+
(1)<b> Primary Waterproofing Membrane: </b>Fully adhered<b> </b>to acceptable substrates (concrete slab depicted)<b> </b>install as per [[RoofStar Guarantee Standards for Waterproofing|'''RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces''']], together with Membrane Manufacturer's installation specifications.  
  
 
(2) <b>Membrane flashing </b>(stripping): carried up wall minimum 200 mm (8") above deck surface and or a minimum of 100mm (4") above top surface of waterproofing assembly.
 
(2) <b>Membrane flashing </b>(stripping): carried up wall minimum 200 mm (8") above deck surface and or a minimum of 100mm (4") above top surface of waterproofing assembly.
Line 11: Line 20:
 
(3) <b>Membrane Primer or Adhesive: </b>proprietary primer or adhesive application and quantities as directed bymembrane manufacturer's published application specifications.  
 
(3) <b>Membrane Primer or Adhesive: </b>proprietary primer or adhesive application and quantities as directed bymembrane manufacturer's published application specifications.  
  
(4) <b>Expansion Joint</b>: Proprietary elastomeric expansion joint system compatible with waterproofing membrane system approved by membrane manufacturer and accepted by RGC. Designed to accommodate specific horizontal building movements and compliant with RGC Guarantee Standards <b>E</b>.  
+
(4) <b>Expansion Joint</b>: Proprietary elastomeric expansion joint system compatible with waterproofing membrane system approved by membrane manufacturer and accepted by RGC. Designed to accommodate specific horizontal building movements and compliant with [[RoofStar Guarantee Standards for Waterproofing#WPEXPANSION|'''3.2 Expansion Joints''']].  
  
(5) <b>Protection Board/Mat: </b>Proprietary membrane protection board or mat approved by membrane manufacture compatible with waterproofing membrane system, and compliant with RGC Guarantee Standards <b>E.</b>
+
(5) <b>Protection Board/Mat: </b>Proprietary membrane protection board or mat approved by membrane manufacture compatible with waterproofing membrane system, and compliant with RoofStar Guarantee Standards.  
  
 
(6) <b>Insulation: </b>Optional: Extruded, Expanded Polystyrene, Type 4, CAN/ULC-S701-97, compressive strength of 240 kpa (35 psi).  
 
(6) <b>Insulation: </b>Optional: Extruded, Expanded Polystyrene, Type 4, CAN/ULC-S701-97, compressive strength of 240 kpa (35 psi).  
Line 19: Line 28:
 
(7) <b>Filter Mat: </b>synthetic permeable fabric required over extruded, expanded polystyrene insulation overburdened with pavers, growing mediums, sand and gravel beds for unit masonry, etc.  
 
(7) <b>Filter Mat: </b>synthetic permeable fabric required over extruded, expanded polystyrene insulation overburdened with pavers, growing mediums, sand and gravel beds for unit masonry, etc.  
  
(8) <b>Metal Cap or Coping Flashing:</b> Must overlap exterior wall finish. See <i>RGC Guarantee Standard A6.9 &amp; A6.10 </i>for fastening and additional requirements.  
+
(8) <b>Metal Cap or Coping Flashing:</b> Must overlap exterior wall finish. See [[RoofStar Guarantee Standards for Waterproofing#WPFASTENER| '''15.3 Attachment''']] for fastening and additional requirements.  
  
 
(9) <b>Metal Base Flashing:</b> Required on all waterproofing assemblies. Flashing lengths joined by use of S-locks or standing seam joints.
 
(9) <b>Metal Base Flashing:</b> Required on all waterproofing assemblies. Flashing lengths joined by use of S-locks or standing seam joints.
Line 27: Line 36:
 
(A) <b>Acceptable Deck</b>: Concrete slab shown.
 
(A) <b>Acceptable Deck</b>: Concrete slab shown.
  
<b><i>NOTE: </i> Refer to<i> RGC Guarantee Standards E </i>for additional requirements.</b>
+
</div><!-- COL-6-MD -->
 +
</div><!-- PANEL BODY -->
 +
</div><!-- PANEL -->
 +
 
 +
'''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements.
  
 
<hr>
 
<hr>
Line 33: Line 46:
  
  
[[Section:F. Application: Waterproofing Plazas, Promenades and Terraces|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Waterproofing Application'']]
 
  
[[Waterproofing Construction Details|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Waterproofing Construction Details'']]
+
[[Section:F. Application: Waterproofing Plazas, Promenades and Terraces|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Waterproofing Application'']]
  
[[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Construction Details'']]
+
[[Waterproofing Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Waterproofing Construction Details'']]
 +
[[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']]

Revision as of 16:10, 1 September 2016

RoofStar Guarantee Standards are blue-linked
Waterproofing Details for Plazas, Promenades and Terraces

F1.7.5.jpg

1 WORK INCLUDED

(1) Primary Waterproofing Membrane: Fully adhered to acceptable substrates (concrete slab depicted) install as per RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces, together with Membrane Manufacturer's installation specifications.

(2) Membrane flashing (stripping): carried up wall minimum 200 mm (8") above deck surface and or a minimum of 100mm (4") above top surface of waterproofing assembly.

(3) Membrane Primer or Adhesive: proprietary primer or adhesive application and quantities as directed bymembrane manufacturer's published application specifications.

(4) Expansion Joint: Proprietary elastomeric expansion joint system compatible with waterproofing membrane system approved by membrane manufacturer and accepted by RGC. Designed to accommodate specific horizontal building movements and compliant with 3.2 Expansion Joints.

(5) Protection Board/Mat: Proprietary membrane protection board or mat approved by membrane manufacture compatible with waterproofing membrane system, and compliant with RoofStar Guarantee Standards.

(6) Insulation: Optional: Extruded, Expanded Polystyrene, Type 4, CAN/ULC-S701-97, compressive strength of 240 kpa (35 psi).

(7) Filter Mat: synthetic permeable fabric required over extruded, expanded polystyrene insulation overburdened with pavers, growing mediums, sand and gravel beds for unit masonry, etc.

(8) Metal Cap or Coping Flashing: Must overlap exterior wall finish. See 15.3 Attachment for fastening and additional requirements.

(9) Metal Base Flashing: Required on all waterproofing assemblies. Flashing lengths joined by use of S-locks or standing seam joints.

2 WORK BY OTHERS

(A) Acceptable Deck: Concrete slab shown.

NOTE: Refer to RoofStar Guarantee Standards for additional requirements.




Back to Waterproofing Application

Back to Waterproofing Construction Details Back to Construction Details