Main Page
Site Nav
Technical Updates
Sections
A - RoofStar Guarantee
B - Essential Elements
C - Accepted Materials
D - Low Slope Roofs
E - Steep Slope Roofs
F - Waterproofing Plazas, Promenades and Terraces
G - Construction Details
H - Build Your Own Roof
I - General Information
Go
Personal
Log in
Page
Page
Discussion
View source
History
Tools
Page information
Permanent link
Printable version
Special pages
Related changes
What links here
Main page
Random page
Help
CSA Tested Assemblies Draft 1
Jump to:
navigation
,
search
CSA Tested Assemblies Draft 1
Revision as of 15:54, 26 May 2020 by
James Klassen
(
talk
|
contribs
)
(
→
PARS: SBS
)
(
diff
)
← Older revision
|
Latest revision
(
diff
) |
Newer revision →
(
diff
)
PARS: SBS
Primary Material
Other System Materials & Deck
Tested Assembly Report Data
Manufacturer
Cap Membrane
Base Membrane
Number of
Plies
Insulation
Overlay
Insulation
Deck Overlay
Deck Type
Roof
Assembly
Summary
Downloadable
Test Report
Dynamic Uplift Resistance
kPa
Psf
Firestone Building Products Canada
View options
SBS Torch
SBS FR Torch
SBS Premium Torch
SBS Premium FR Torch
View options
BaseGard SA
SBS Base
SBS Poly Base
SBS Premium Base
2
View options
ISOGard HD
Securerock Glass-Mat Roof Board
View options
Resista
View options
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: self-adhered
Insulation overlay
: mechanically fastened
Insulation (top layer)
: various securement options
Insulation (bottom layer)
: various securement options
Air/Vapour control layer
: various securement options
Deck overlay (thermal barrier)
: optional
Roof deck
FIR PARS 1-A
-2.1
-45
Henry Company Canada
View options
NP250gT
View options
NP180 Tack
2
View options
Securerock Glass-Mat Roof Board
View options
Atlas AC Foam III
View options
Optional (none listed)
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: adhered
Insulation overlay
: loose-laid
Insulation (top layer)
: loose-laid
Insulation (bottom layer)
: loose-laid
Air/Vapour control layer
: Optional (adhered or self-adhered
Deck overlay (thermal barrier)
: Optional (none listed)
Roof deck
HEN PARS 1-A
-4.67
-97.5
IKO Industries Ltd.
View options
Torchflex TP-250
Torchflex TP-HD
Torchflex TP-250 5 mm
Torchflex TP-180
Prevent TP-250
Prevent Premium TP-250
Prevent TP-HD
Carrara Armourcool HD
Modiflex MP-180 Cap
Modiflex MP-HD-Cap
Modiflex MP-250-Cap
Prevent MP-HD-Cap
View options
Torchflex TF-95 FF 2.2 mm
Torchflex TP-180 FF
Torchflex HD-FF-Base
2
View options
Protectoboard
View options
IKOTherm III
View options
None listed
View options
Steel
View summary
Cap membrane:
torch-applied or hot-mopped*
Base membrane:
torch-applied or hot-mopped*
Insulation overlay:
mechanically fastened
Insulation (top layer):
loose-laid
Insulation (bottom layer):
N/A
Air/Vapour control layer:
loose-laid and spliced
Deck overlay (thermal barrier):
mechanically fastened
Roof deck
* Refer to the specific application requirements for each material
IKO PARS 1-A
-1.4
-29.0
IKO Industries Ltd.
View options
Torchflex TP-250
Torchflex TP-HD
Torchflex TP-250 5 mm
Torchflex TP-180
Prevent TP-250
Prevent Premium TP-250
Prevent TP-HD
Carrara Armourcool HD
Modiflex MP-180 Cap
Modiflex MP-HD-Cap
Modiflex MP-250-Cap
Prevent MP 250 Cap 4 mm
Prevent MP-HD-Cap
View options
Torchflex TF-95 FF 2.2 mm
Torchflex TP-180 FF
Torchflex HD-FF-Base
2
View options
Protectoboard
View options
IKOTherm III
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied or hot-mopped*
Base membrane
: torch-applied or hot-mopped*
Insulation overlay
: mechanically fastened
Insulation (top layer)
: loose-laid
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: loose-laid and spliced
Deck overlay (thermal barrier)
: N/A
Roof deck
* Refer to the specific application requirements for each material
IKO PARS 2-A
-2.3
-48.0
IKO Industries Ltd.
View options
Torchflex TP-250
Torchflex TP-HD
Torchflex TP-250 5 mm
Torchflex TP-180
Prevent TP-250
Prevent Premium TP-250
Prevent TP-HD
Carrara Armourcool HD
Prevent Armourcool HD Cap
Modiflex MP-180 Cap
Modiflex MP-HD-Cap
Modiflex MP-250-Cap
Prevent MP 250 Cap 4 mm
Prevent MP-HD-Cap
View options
Armourvent Base
Armourbond 180
Armourbond Flash
2
View options
IKOTherm Covershield
View options
IKOTherm III
View options
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
Securerock Glass-Mat Roof Board
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: self-adhered on primer
Insulation overlay
: mechanically attached
Insulation (top layer)
: loose-laid
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: N/A
Deck overlay (thermal barrier)
: N/A
Roof deck
IKO PARS 3-A
-1.8
-37.5
IKO Industries Ltd.
View options
Torchflex TP-250
Torchflex TP-HD
Torchflex TP-250 5 mm
Torchflex TP-180
Prevent TP-250
Prevent Premium TP-250
Prevent TP-HD
Carrara Armourcool HD
Prevent Armourcool HD Cap
Modiflex MP-180 Cap
Modiflex MP-HD-Cap
Modiflex MP-250-Cap
Prevent MP 250 Cap 4 mm
Prevent MP-HD-Cap
View options
Torchflex TF-95 FF
Torchflex TP-180 FF
Torchflex HD-FF-Base
Modiflex MF-95 S/S
Modiflex MP-180 F/S
Modiflex MP-180 SS
Modiflex MP-180 F/S 3 mm
2
View options
Protectoboard
Protectobase 180
ShieldBase 180
View options
IKOTherm III
View options
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
Securerock Glass-Mat Roof Board
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: adhered
Insulation (top layer)
: mechanically fastened
Insulation (bottom layer)
: various securement options
Air/Vapour control layer
: self-adhered
Deck overlay (thermal barrier)
: loose-laid
Roof deck
IKO PARS 4-A
-3.6
-75
IKO Industries Ltd.
View options
Torchflex TP-250
Torchflex TP-HD
Torchflex TP-250 5 mm
Torchflex TP-180
Prevent TP-250
Prevent Premium TP-250
Prevent TP-HD
Carrara Armourcool HD
Prevent Armourcool HD Cap
Modiflex MP-180 Cap
Modiflex MP-HD-Cap
Modiflex MP-250-Cap
Prevent MP 250 Cap 4 mm
Prevent MP-HD-Cap
View options
Torchflex TF-95 FF
Torchflex TP-180 FF
Torchflex HD-FF-Base
Modiflex MF-95 S/S
Modiflex MP-180 F/S
Modiflex MP-180 SS
Modiflex MP-180 F/S 3 mm
2
View options
Protectoboard
View options
IKOTherm III
View options
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: adhered
Insulation (top layer)
: adhered
Insulation (bottom layer)
: mechanically fastened
Air/Vapour control layer
: loose-laid and spliced
Deck overlay (thermal barrier)
: loose-laid
Roof deck
IKO PARS 5-A
-3
-62
IKO Industries Ltd.
View options
Torchflex TP-250
Torchflex TP-HD
Torchflex TP-250 5 mm
Torchflex TP-180
Prevent TP-250
Prevent Premium TP-250
Prevent TP-HD
Carrara Armourcool HD
Prevent Armourcool HD Cap
Modiflex MP-180 Cap
Modiflex MP-HD-Cap
Modiflex MP-250-Cap
Prevent MP 250 Cap 4 mm
Prevent MP-HD-Cap
View options
Torchflex TF-95 FF
Torchflex TP-180 FF
Torchflex HD-FF-Base
Modiflex MF-95 S/S
Modiflex MP-180 F/S
Modiflex MP-180 SS
Modiflex MP-180 F/S 3 mm
2
View options
Protectoboard
Protectobase 180
ShieldBase 180
View options
IKOTherm III
View options
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
Securerock Glass-Mat Roof Board
View options
Steel
View summary
Cap membrane
: torch-welded
Base membrane
: torch-welded
Insulation overlay
: adhered
Insulation (top layer)
: mechanically attached
Insulation (bottom layer)
: loose-laid
Air/Vapour control layer
: loose-laid
Deck overlay (thermal barrier)
: various securement options
Roof deck
IKO PARS 6-A
-2.4
-50
IKO Industries Ltd.
View options
Torchflex TP-250
Torchflex TP-HD
Torchflex TP-250 5 mm
Torchflex TP-180
Prevent TP-250
Prevent Premium TP-250
Prevent TP-HD
Carrara Armourcool HD
Prevent Armourcool HD Cap
Modiflex MP-180 Cap
Modiflex MP-HD-Cap
Modiflex MP-250-Cap
Prevent MP 250 Cap 4 mm
Prevent MP-HD-Cap
View options
Torchflex TF-95 FF
Torchflex TP-180 FF
Torchflex HD-FF-Base
Modiflex MF-95 S/S
Modiflex MP-180 F/S
Modiflex MP-180 SS
Modiflex MP-180 F/S 3 mm
2
View options
Protectoboard
Protectobase 180
View options
IKOTherm III
View options
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
Securerock Glass-Mat Roof Board
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: mechanically attached
Insulation (top layer)
: various securement options
Insulation (bottom layer)
: various securement options
Air/Vapour control layer
: self-adhered on primer
Deck overlay (thermal barrier)
: various securement options
Roof deck
IKO PARS 7-A
-1.4
-30
IKO Industries Ltd.
View options
Torchflex TP-250
Torchflex TP-HD
Torchflex TP-250 5 mm
Torchflex TP-180
Prevent TP-250
Prevent Premium TP-250
Prevent TP-HD
Carrara Armourcool HD
Prevent Armourcool HD Cap
Modiflex MP-180 Cap
Modiflex MP-HD-Cap
Modiflex MP-250-Cap
Prevent MP 250 Cap 4 mm
Prevent MP-HD-Cap
View options
Armourvent Base
Armourbond 180
Armourbond Flash
2
View options
IKOTherm Covershield
View options
IKOTherm III
View options
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
Securerock Glass-Mat Roof Board
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: self-adhered on primer
Insulation overlay
: adhered
Insulation (top layer)
: mechanically attached
Insulation (bottom layer)
: loose-laid
Air/Vapour control layer
: self-adhered on primer
Deck overlay (thermal barrier)
: various securement options
Roof deck
IKO PARS 8-A
-2.4
-50
IKO Industries Ltd.
View options
Torchflex TP-250
Torchflex TP-HD
Torchflex TP-250 5 mm
Torchflex TP-180
Prevent TP-250
Prevent Premium TP-250
Prevent TP-HD
Carrara Armourcool HD
Prevent Armourcool HD Cap
Modiflex MP-180 Cap
Modiflex MP-HD-Cap
Modiflex MP-250-Cap
Prevent MP 250 Cap 4 mm
Prevent MP-HD-Cap
View options
Torchflex TF-95 FF
Torchflex TP-180 FF
Torchflex HD-FF-Base
Modiflex MF-95 S/S
Modiflex MP-180 F/S
Modiflex MP-180 SS
Modiflex MP-180 F/S 3 mm
2
View options
Protectoboard
Protectobase 180
View options
IKOTherm III
View options
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
Securerock Glass-Mat Roof Board
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: adhered
Insulation (top layer)
: mechanically attached
Insulation (bottom layer)
: various securement options
Air/Vapour control layer
: self-adhered on primer
Deck overlay (thermal barrier)
: various securement options
Roof deck
IKO PARS 9-A
-2.4
-50
IKO Industries Ltd.
View options
Torchflex TP-250
Torchflex TP-HD
Torchflex TP-250 5 mm
Torchflex TP-180
Prevent TP-250
Prevent Premium TP-250
Prevent TP-HD
Carrara Armourcool HD
Prevent Armourcool HD Cap
Modiflex MP-180 Cap
Modiflex MP-HD-Cap
Modiflex MP-250-Cap
Prevent MP 250 Cap 4 mm
Prevent MP-HD-Cap
View options
Torchflex TF-95 FF
Torchflex TP-180 FF
Torchflex HD-FF-Base
Modiflex MF-95 S/S
Modiflex MP-180 F/S
Modiflex MP-180 SS
Modiflex MP-180 F/S 3 mm
2
View options
DensDeck® Prime with EONIC Roof Board
Securerock Gypsum Fibre Roof Board
Securerock Glass-Mat Roof Board
View options
IKOTherm III
View options
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
Securerock Glass-Mat Roof Board
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: mechanically attached
Insulation (top layer)
: various securement options
Insulation (bottom layer)
: various securement options
Air/Vapour control layer
: loose-laid or adhered on primer
Deck overlay (thermal barrier)
: various securement options
Roof deck
IKO PARS 13-A
-2.2
-47
IKO Industries Ltd.
View options
Torchflex TP-250
Torchflex TP-HD
Torchflex TP-250 5 mm
Torchflex TP-180
Prevent TP-250
Prevent Premium TP-250
Prevent TP-HD
Carrara Armourcool HD
Prevent Armourcool HD Cap
Modiflex MP-180 Cap
Modiflex MP-HD-Cap
Modiflex MP-250-Cap
Prevent MP 250 Cap 4 mm
Prevent MP-HD-Cap
View options
Torchflex TP-180 FF (with Protectoboard) or composite overlay
2
View options
Protectoboard
Protectobase 180
View options
IKOTherm III
View options
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
Securerock Glass-Mat Roof Board
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied (optional)
Insulation overlay
: adhered (composite overlay)
Insulation (top layer)
: adhered
Insulation (bottom layer)
: adhered
Air/Vapour control layer
: torch-applied
Deck overlay (thermal barrier)
: mechanically attached
Roof deck
IKO PARS 14-A
-4.2
-80
IKO Industries Ltd.
View options
Torchflex TP-250
Torchflex TP-HD
Torchflex TP-250 5 mm
Torchflex TP-180
Prevent TP-250
Prevent Premium TP-250
Prevent TP-HD
Carrara Armourcool HD
Prevent Armourcool HD Cap
Modiflex MP-180 Cap
Modiflex MP-HD-Cap
Modiflex MP-250-Cap
Prevent MP 250 Cap 4 mm
Prevent MP-HD-Cap
View options
Torchflex TF-95 FF
Torchflex TP-180 FF
Torchflex HD-FF-Base
Modiflex MF-95 S/S
Modiflex MP-180 F/S
Modiflex MP-180 SS
Modiflex MP-180 F/S 3 mm
2
View options
Protectoboard
Protectobase 180
View options
IKOTherm III
View options
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
Securerock Glass-Mat Roof Board
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: mechanically attached
Insulation (top layer)
: various securement options
Insulation (bottom layer)
: various securement options
Air/Vapour control layer
: loose-laid or adhered on primer
Deck overlay (thermal barrier)
: various securement options
Roof deck
IKO PARS 15-A
-1.9
-40
IKO Industries Ltd.
View options
Torchflex TP-250
Torchflex TP-HD
Torchflex TP-250 5 mm
Torchflex TP-180
Prevent TP-250
Prevent Premium TP-250
Prevent TP-HD
Carrara Armourcool HD
Prevent Armourcool HD Cap
Modiflex MP-180 Cap
Modiflex MP-HD-Cap
Modiflex MP-250-Cap
Prevent MP 250 Cap 4 mm
Prevent MP-HD-Cap
View options
Torchflex TF-95 FF
Torchflex TP-180 FF
Torchflex HD-FF-Base
Modiflex MF-95 S/S
Modiflex MP-180 F/S
Modiflex MP-180 SS
Modiflex MP-180 F/S 3 mm
2
View options
Protectoboard
Protectobase 180
View options
IKOTherm III
View options
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
Securerock Glass-Mat Roof Board
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: mechanically attached
Insulation (top layer)
: various securement options
Insulation (bottom layer)
: various securement options
Air/Vapour control layer
: loose-laid or adhered on primer
Deck overlay (thermal barrier)
: various securement options
Roof deck
IKO PARS 16-A
-1.9
-40
IKO Industries Ltd.
View options
Torchflex TP-250
Torchflex TP-HD
Torchflex TP-250 5 mm
Torchflex TP-180
Prevent TP-250
Prevent Premium TP-250
Prevent TP-HD
Carrara Armourcool HD
Prevent Armourcool HD Cap
Modiflex MP-180 Cap
Modiflex MP-HD-Cap
Modiflex MP-250-Cap
Prevent MP 250 Cap 4 mm
Prevent MP-HD-Cap
View options
Torchflex TP-180 FF (with Protectoboard) or composite overlay
2
View options
Protectoboard
Protectobase 180
Protectoboard
View options
IKOTherm III
View options
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
Securerock Glass-Mat Roof Board
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied (optional)
Insulation overlay
: mechanically fastened (composite overlay)
Insulation (top layer)
: avarious securement options
Insulation (bottom layer)
: various securement options
Air/Vapour control layer
: self-adhered on primer
Deck overlay (thermal barrier)
: various securement options
Roof deck
IKO PARS 17-A
-6.7
-140
Polyglass USA, Inc.
View options
Polyfresko G
Polyfresko G FR
Elastoflex S6 G
Elastoflex S6 G FR
Elastoshield TS-G FR
View options
Elastobase (poly/poly)
Elastoflex V
Elastoflex S6
Elastoflex SA V
Elastoflex SA V FR
2 or 3
View options
DensDeck® Prime with EONIC Roof Board
Securerock Gypsum Fibre Roof Board
View options
ENRGY 3 (JM)
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Interply membrane (optional)
: torch-applied
Base membrane
: self-adhered
Insulation overlay
: adhered
Insulation (top layer)
: none listed
Insulation (bottom layer)
: mechanically fastened
Air/Vapour control layer
: loose-laid, sealed at laps
Deck overlay (thermal barrier)
: none
Roof deck
POL PARS 1-A
-3.1
-64
Polyglass USA, Inc.
View options
Polyfresko G
Polyfresko G FR
Elastoflex S6 G
Elastoflex S6 G FR
Elastoshield TS-G FR
View options
Elastobase
Elastoflex V
Elastoflex S6
Elastoflex SA V
Elastoflex SA V FR
2 or 3
View options
None listed
View options
ENRGY 3 (JM)
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Interply membrane (optional)
: torch-applied
Base membrane
: self-adhered
Insulation overlay
: none
Insulation (top layer)
: adhered
Insulation (bottom layer)
: mechanically fastened
Air/Vapour control layer
: loose-laid, sealed at laps
Deck overlay (thermal barrier)
: none
Roof deck
POL PARS 2-A
-3.1
-64
Polyglass USA, Inc.
View options
Polyfresko G
Polyfresko G FR
Elastoflex S6 G
Elastoflex S6 G FR
Elastoshield TS-G FR
View options
Elastobase (poly/poly)
Elastoflex V
Elastoflex S6
Elastoflex SA V
Elastoflex SA V FR
2 or 3
View options
DensDeck® Prime with EONIC Roof Board
Securerock Gypsum Fibre Roof Board
View options
No Accepted Material: Consult manufacturer
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Interply membrane (optional)
: torch-applied
Base membrane
: self-adhered
Insulation overlay
: adhered
Insulation (top layer)
: none
Insulation (bottom layer)
: mechanically fastened
Air/Vapour control layer
: loose-laid, sealed at laps
Deck overlay (thermal barrier)
: none
Roof deck
POL PARS 3-A
-3.1
-64
Polyglass USA, Inc.
View options
Polyfresko G
Polyfresko G FR
Elastoflex S6 G
Elastoflex S6 G FR
Elastoshield TS-G FR
View options
Elastobase (poly/poly)
Elastoflex V
Elastoflex S6
Elastoflex SA V
Elastoflex SA V FR
2 or 3
View options
DensDeck® Prime with EONIC Roof Board
Securerock Gypsum Fibre Roof Board
View options
No Accepted Material: Consult manufacturer
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Interply membrane (optional)
: torch-applied
Base membrane
: self-adhered
Insulation overlay
: adhered
Insulation (top layer)
: none
Insulation (bottom layer)
: mechanically fastened
Air/Vapour control layer
: loose-laid, sealed at laps
Deck overlay (thermal barrier)
: none
Roof deck
POL PARS 4-A
-3.1
-64
Polyglass USA, Inc.
View options
Polyfresko G
Polyfresko G FR
Elastoflex S6 G
Elastoflex S6 G FR
Elastoshield TS-G FR
View options
Elastobase (poly/poly)
Elastoflex V
Elastoflex S6
Elastoflex SA V
Elastoflex SA V FR
2 or 3
View options
No Accepted Material: Consult manufacturer
View options
No Accepted Material: Consult manufacturer
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Interply membrane (optional)
: torch-applied
Base membrane
: self-adhered
Insulation overlay
: adhered
Insulation (top layer)
: none
Insulation (bottom layer)
: mechanically fastened
Air/Vapour control layer
: loose-laid, sealed at laps
Deck overlay (thermal barrier)
: none
Roof deck
POL PARS 5-A
-3.1
-64
Polyglass USA, Inc.
View options
Polyfresko G
Polyfresko G FR
Elastoflex S6 G
Elastoflex S6 G FR
Elastoshield TS-G FR
View options
Elastobase (poly/poly)
Elastoflex V
Elastoflex S6
Elastoflex SA V
Elastoflex SA V FR
2 or 3
View options
DensDeck® Prime with EONIC Roof Board
Securerock Gypsum Fibre Roof Board
View options
No Accepted Material: Consult manufacturer
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Interply membrane (optional)
: torch-applied
Base membrane
: self-adhered
Insulation overlay
: adhered
Insulation (top layer)
: none
Insulation (bottom layer)
: mechanically fastened
Air/Vapour control layer
: loose-laid, sealed at laps
Deck overlay (thermal barrier)
: none
Roof deck
POL PARS 6-A
-3.1
-64
Polyglass USA, Inc.
View options
Polyfresko G
Polyfresko G FR
Elastoflex S6 G
Elastoflex S6 G FR
Elastoshield TS-G FR
View options
Elastobase (poly/poly)
Elastoflex V
Elastoflex S6
Elastoflex SA V
Elastoflex SA V FR
2 or 3
View options
No Accepted Material: Consult manufacturer
View options
No Accepted Material: Consult manufacturer
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Interply membrane (optional)
: torch-applied
Base membrane
: self-adhered
Insulation overlay
: adhered
Insulation (top layer)
: none
Insulation (bottom layer)
: mechanically fastened
Air/Vapour control layer
: loose-laid, sealed at laps
Deck overlay (thermal barrier)
: none
Roof deck
POL PARS 7-A
-3.1
-64
Polyglass USA, Inc.
View options
Polyfresko G
Polyfresko G FR
Elastoflex S6 G
Elastoflex S6 G FR
Elastoshield TS-G FR
View options
Elastobase (poly/poly)
Elastoflex V
Elastoflex S6
2 or 3
View options
DensDeck® Prime with EONIC Roof Board
View options
ENRGY 3 (JM)
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Interply membrane (optional)
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: adhered
Insulation (top layer)
: none
Insulation (bottom layer)
: mechanically fastened
Air/Vapour control layer
: loose-laid, sealed at laps
Deck overlay (thermal barrier)
: none
Roof deck
POL PARS 8-A
-3.1
-64
Polyglass USA, Inc.
View options
Polyfresko G
Polyfresko G FR
Elastoflex S6 G
Elastoflex S6 G FR
Elastoshield TS-G FR
View options
Elastobase (poly/poly)
Elastoflex V
Elastoflex S6
2 or 3
View options
None listed
View options
ENRGY 3 (JM)
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Interply membrane (optional)
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: adhered
Insulation (top layer)
: none
Insulation (bottom layer)
: mechanically fastened
Air/Vapour control layer
: loose-laid, sealed at laps
Deck overlay (thermal barrier)
: none
Roof deck
POL PARS 9-A
-3.1
-64
Polyglass USA, Inc.
View options
Polyfresko G
Polyfresko G FR
Elastoflex S6 G
Elastoflex S6 G FR
Elastoshield TS-G FR
View options
Elastobase (poly/poly)
Elastoflex V
Elastoflex S6
2 or 3
View options
DensDeck® Prime with EONIC Roof Board
Securerock Gypsum Fibre Roof Board
View options
ENRGY 3 (JM)
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Interply membrane (optional)
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: adhered
Insulation (top layer)
: none
Insulation (bottom layer)
: mechanically fastened
Air/Vapour control layer
: loose-laid, sealed at laps
Deck overlay (thermal barrier)
: none
Roof deck
POL PARS 10-A
-3.1
-64
Polyglass USA, Inc.
View options
Polyfresko G
Polyfresko G FR
Elastoflex S6 G
Elastoflex S6 G FR
Elastoshield TS-G FR
View options
Elastobase (poly/poly)
Elastoflex V
Elastoflex S6
2 or 3
View options
DDensDeck® Prime with EONIC Roof Board
View options
ENRGY 3 (JM)
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Interply membrane (optional)
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: adhered
Insulation (top layer)
: none
Insulation (bottom layer)
: mechanically fastened
Air/Vapour control layer
: loose-laid, sealed at laps
Deck overlay (thermal barrier)
: none
Roof deck
POL PARS 11-A
-3.1
-64
Polyglass USA, Inc.
View options
Polyfresko G
Polyfresko G FR
Elastoflex S6 G
Elastoflex S6 G FR
Elastoshield TS-G FR
View options
Elastobase (poly/poly)
Elastoflex V
Elastoflex S6
2 or 3
View options
No Accepted Material: Consult manufacturer
View options
No Accepted Material: Consult manufacturer
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Interply membrane (optional)
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: adhered
Insulation (top layer)
: none
Insulation (bottom layer)
: mechanically fastened
Air/Vapour control layer
: loose-laid, sealed at laps
Deck overlay (thermal barrier)
: none
Roof deck
POL PARS 12-A
-3.1
-64
Polyglass USA, Inc.
View options
Polyfresko G
Polyfresko G FR
Elastoflex S6 G
Elastoflex S6 G FR
Elastoshield TS-G FR
View options
Elastobase (poly/poly)
Elastoflex V
Elastoflex S6
2 or 3
View options
DensDeck® Prime with EONIC Roof Board
View options
ENRGY 3 (JM)
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Interply membrane (optional)
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: adhered
Insulation (top layer)
: none
Insulation (bottom layer)
: mechanically fastened
Air/Vapour control layer
: loose-laid, sealed at laps
Deck overlay (thermal barrier)
: none
Roof deck
POL PARS 13-A
-3.1
-64
Polyglass USA, Inc.
View options
Polyfresko G
Polyfresko G FR
Elastoflex S6 G
Elastoflex S6 G FR
Elastoshield TS-G FR
View options
Elastobase (poly/poly)
Elastoflex V
Elastoflex S6
2 or 3
View options
No Accepted Material: Consult manufacturer
View options
No Accepted Material: Consult manufacturer
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Interply membrane (optional)
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: adhered
Insulation (top layer)
: none
Insulation (bottom layer)
: mechanically fastened
Air/Vapour control layer
: loose-laid, sealed at laps
Deck overlay (thermal barrier)
: none
Roof deck
POL PARS 14-A
-3.1
-64
Polyglass USA, Inc.
View options
Polyfresko G
Polyfresko G FR
Elastoflex S6 G
Elastoflex S6 G FR
Elastoshield TS-G FR
View options
Elastobase (poly/poly)
Elastoflex V
Elastoflex S6
2 or 3
View options
Securerock Gypsum Fibre Roof Board
View options
ENRGY 3 (JM)
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Interply membrane (optional)
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: adhered
Insulation (top layer)
: none
Insulation (bottom layer)
: mechanically fastened
Air/Vapour control layer
: loose-laid, sealed at laps
Deck overlay (thermal barrier)
: none
Roof deck
POL PARS 15-A
-3.1
-64
Polyglass USA, Inc.
View options
Polyfresko G
Polyfresko G FR
Elastoflex S6 G
Elastoflex S6 G FR
Elastoshield TS-G FR
View options
Elastobase (poly/poly)
Elastoflex V
Elastoflex S6
2 or 3
View options
Securerock Gypsum Fibre Roof Board
View options
No Accepted Material: Consult manufacturer
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Interply membrane (optional)
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: adhered
Insulation (top layer)
: none
Insulation (bottom layer)
: mechanically fastened
Air/Vapour control layer
: loose-laid, sealed at laps
Deck overlay (thermal barrier)
: none
Roof deck
POL PARS 15-A
-3.1
-64
Polyglass USA, Inc.
View options
Polyfresko G
Polyfresko G FR
Elastoflex S6 G
Elastoflex S6 G FR
Elastoshield TS-G FR
View options
Elastobase (poly/poly)
Elastoflex V
Elastoflex S6
2 or 3
View options
Securerock Gypsum Fibre Roof Board
View options
No Accepted Material: Consult manufacturer
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Interply membrane (optional)
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: adhered
Insulation (top layer)
: none
Insulation (bottom layer)
: mechanically fastened
Air/Vapour control layer
: loose-laid, sealed at laps
Deck overlay (thermal barrier)
: none
Roof deck
POL PARS 17-A
-3.1
-64
Polyglass USA, Inc.
View options
Polyfresko G
Polyfresko G FR
Elastoflex S6 G
Elastoflex S6 G FR
Elastoshield TS-G FR
View options
Elastobase (poly/poly)
Elastoflex V
Elastoflex S6
2 or 3
View options
Securerock Gypsum Fibre Roof Board
View options
No Accepted Material: Consult manufacturer
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Interply membrane (optional)
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: adhered
Insulation (top layer)
: none
Insulation (bottom layer)
: mechanically fastened
Air/Vapour control layer
: loose-laid, sealed at laps
Deck overlay (thermal barrier)
: none
Roof deck
POL PARS 18-A
-3.1
-64
Polyglass USA, Inc.
View options
Polyfresko G
Polyfresko G FR
Elastoflex S6 G
Elastoflex S6 G FR
Elastoshield TS-G FR
View options
Elastoflex V
Elastoflex S6
2 or 3
View options
Securerock Gypsum Fibre Roof Board
View options
No Accepted Material: Consult manufacturer
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Interply membrane (optional)
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: mechanically fastened
Insulation (top layer)
: loose-laid
Insulation (bottom layer)
: loose-laid
Air/Vapour control layer
: self-adhered
Deck overlay (thermal barrier) - optional
: various securement methods
Roof deck
POL PARS 19-A
-3.4
-70
Polyglass USA, Inc.
View options
Polyfresko G
Polyfresko G FR
Elastoflex S6 G
Elastoflex S6 G FR
Elastoshield TS-G FR
View options
Elastoflex V
Elastoflex S6
2 or 3
View options
Sopraboard (Soprema)
View options
No Accepted Material: Consult manufacturer
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Interply membrane (optional)
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: mechanically fastened
Insulation (top layer)
: loose-laid
Insulation (bottom layer)
: loose-laid
Air/Vapour control layer
: self-adhered
Deck overlay (thermal barrier) - optional
: various securement methods
Roof deck
POL PARS 20-A
-1.4
-30
Polyglass USA, Inc.
View options
Polyfresko G
Polyfresko G FR
Elastoflex S6 G
Elastoflex S6 G FR
Elastoshield TS-G FR
View options
Elastoflex V
Elastoflex S6
2 or 3
View options
Sopraboard (Soprema)
View options
No Accepted Material: Consult manufacturer
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Interply membrane (optional)
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: mechanically fastened
Insulation (top layer)
: loose-laid
Insulation (bottom layer)
: loose-laid
Air/Vapour control layer
: loose-laid, sealed at laps
Deck overlay (thermal barrier) - optional
: various securement methods
Roof deck
POL PARS 21-A
-1.8
-38
Polyglass USA, Inc.
View options
Polyfresko G
Polyfresko G FR
Elastoflex S6 G
Elastoflex S6 G FR
Elastoshield TS-G FR
View options
Elastoflex V
Elastoflex S6
2 or 3
View options
DensDeck® Prime with EONIC Roof Board
View options
No Accepted Material: Consult manufacturer
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Interply membrane (optional)
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: mechanically fastened
Insulation (top layer)
: loose-laid
Insulation (bottom layer)
: loose-laid
Air/Vapour control layer
: self-adhered
Deck overlay (thermal barrier) - optional
: various securement methods
Roof deck
POL PARS 22-A
-3.4
-72
Polyglass USA, Inc.
View options
Polyfresko G
Polyfresko G FR
Elastoflex S6 G
Elastoflex S6 G FR
Elastoshield TS-G FR
View options
Elastoflex V
Elastoflex S6
2 or 3
View options
Securerock Gypsum Fibre Roof Board
View options
No Accepted Material: Consult manufacturer
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Interply membrane (optional)
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: mechanically fastened
Insulation (top layer)
: loose-laid
Insulation (bottom layer)
: loose-laid
Air/Vapour control layer
: self-adhered
Deck overlay (thermal barrier) - optional
: various securement methods
Roof deck
POL PARS 23-A
-3.4
-72
Siplast
View options
Paradiene 30 TG
View options
Paradiene 20 TG
2
View options
DensDeck® Prime with EONIC Roof Board
View options
Paratherm CG
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: self-adhered
Insulation overlay
: adhered
Insulation (top layer)
: adhered
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: torch-applied
Deck overlay (thermal barrier)
: mechanically attached
Roof deck
SIP PARS 1-A
-1.9
-40
Siplast
View options
Paradiene 30 TG
View options
Paradiene 20 SA
2
View options
None listed
View options
None listed
View options
No Accepted Material: Consult manufacturer
View options
Plywood
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: N/A
Insulation (top layer)
: N/A
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: N/A
Deck overlay (thermal barrier)
: mechanically fastened
Roof deck
SIP PARS 2-A
-1.4
-30
Siplast
View options
Paradiene 30
View options
Paradiene 20
2
View options
DensDeck® Prime with EONIC Roof Board
View options
Paratherm CG
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: self-adhered
Insulation overlay
: adhered
Insulation (top layer)
: adhered
Insulation (bottom layer)
: mechanically attached
Air/Vapour control layer
: self-adhered
Deck overlay (thermal barrier)
: mechanically attached
Roof deck
SIP PARS 3-A
-2.23
-46.67
Siplast
View options
Paradiene 30
View options
Paradiene 20
2
View options
No Accepted Material: Consult manufacturer
View options
No Accepted Material: Consult manufacturer
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: None listed
Insulation (top layer)
: adhered
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: self-adhered
Deck overlay (thermal barrier)
: N/A
Roof deck
SIP PARS 4-A
-3.35
-70
Siplast
View options
Paradiene 30 TG
View options
Paradiene 20 TG
2
View options
DensDeck® Prime with EONIC Roof Board
View options
No Accepted Material: Consult manufacturer
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: adhered
Insulation (top layer)
: adhered
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: torch-applied
Deck overlay (thermal barrier)
: mechanically fastened
Roof deck
SIP PARS 5-A
-1.8
-37
Siplast
View options
Paradiene 30 TG
View options
Paradiene 20 TG
2
View options
DensDeck® Prime with EONIC Roof Board
View options
No Accepted Material: Consult manufacturer
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: adhered
Insulation (top layer)
: mechanically attached
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: self-adhered
Deck overlay (thermal barrier)
: N/A
Roof deck
SIP PARS 6-A
-2.86
-60
Siplast
View options
Paradiene 30 TG
View options
Paradiene 20
2
View options
Protectoboard (IKO)
View options
No Accepted Material: Consult manufacturer
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: hot-mopped with bitumen
Insulation overlay
: hot-mopped with bitumen
Insulation (top layer)
: hot-mopped with bitumen
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: self-adhered
Deck overlay (thermal barrier)
: mechanically fastened
Roof deck
SIP PARS 7-A
-2.9
-60
Siplast
View options
Paradiene 30 TG
View options
Paradiene 20 TG
2
View options
No Accepted Material: Consult manufacturer
View options
No Accepted Material: Consult manufacturer
View options
None listed
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: adhered
Insulation (top layer)
: mechanically attached
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: self-adhered
Deck overlay (thermal barrier)
: N/A
Roof deck
SIP PARS 8-A
-1.46
-30
Soprema Inc.
View options
Sopralene Flam 180 GR
Sopralene Flam 250 GR
Soprastar Flam HD GR
Sopralene Mammouth GR
Soprafix Traffic Cap 660
Soprafix Traffic Cap FR 661
Sopraply Traffic Cap 560
Sopraply Traffic Cap FR 561
View options
Sopraflash Flam Stick
Colvent 830 (formerly Colvent 810)
2
View options
Sopraboard
View options
Sopra-Iso Plus
SopraRock DD
SopraRock DD Plus
SopraRock MD
SopraRock MD Plus
ACFoam III (Atlas)
ENRGY 3 CGF (JM)
H-Shield CG (Hunter)
View options
Optional (None listed)
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: self-adhered
Insulation overlay
: mechanically attached
Insulation (top layer)
: various securement options
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: various securement options
Deck overlay (thermal barrier)
: N/A
Roof deck
SOP PARS 1-A
-1.4
-30
Soprema Inc.
View options
Sopralene Flam 180 GR
Sopralene Flam 250 GR
Soprastar Flam HD GR
Sopralene Mammouth GR
Soprafix Traffic Cap 660
Soprafix Traffic Cap FR 661
Sopraply Traffic Cap 560
Sopraply Traffic Cap FR 561
View options
Sopraflash Flam Stick
Colvent 830 (formerly Colvent 810)
2
View options
Sopraboard
View options
Sopra-Iso Plus
SopraRock DD
SopraRock DD Plus
SopraRock MD
SopraRock MD Plus
ACFoam III (Atlas)
ENRGY 3 CGF (JM)
H-Shield CG (Hunter)
View options
Optional (None listed)
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: self-adhered
Insulation overlay
: mechanically attached
Insulation (top layer)
: various securement options
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: various securement options
Deck overlay (thermal barrier)
: N/A
Roof deck
SOP PARS 1-B
-2.3
-48
Soprema Inc.
View options
Sopralene Flam 180 GR
Sopralene Flam 250 GR
Soprastar Flam HD GR
Sopralene Mammouth GR
Soprafix Traffic Cap 660
Soprafix Traffic Cap FR 661
Sopraply Traffic Cap 560
Sopraply Traffic Cap FR 561
View options
Sopraflash Flam Stick
Colvent 830 (formerly Colvent 810)
2
View options
Sopraboard
View options
Sopra-Iso Plus
SopraRock DD
SopraRock DD Plus
SopraRock MD
SopraRock MD Plus
ACFoam III (Atlas)
ENRGY 3 CGF (JM)
H-Shield CG (Hunter)
View options
Optional (None listed)
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: self-adhered
Insulation overlay
: mechanically attached
Insulation (top layer)
: various securement options
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: various securement options
Deck overlay (thermal barrier)
: N/A
Roof deck
SOP PARS 1-C
-2.8
-58
Soprema Inc.
View options
Sopralene Flam 180 GR
Sopralene Flam 250 GR
Soprastar Flam HD GR
Sopralene Mammouth GR
Sopraply Traffic Cap 560
Sopraply Traffic Cap FR 561
View options
Elastophene Flam
Sopralene Flam 180
Sopralene Flam 250
Sopraply Base 520
2
View options
SopraRock DD Plus
View options
Sopra-Iso Plus
SopraRock DD
SopraRock DD Plus
SopraRock MD
SopraRock MD Plus
ACFoam III (Atlas)
ENRGY 3 CGF (JM)
H-Shield CG (Hunter)
View options
Securerock Gypsum Fibre Roof Board
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: adhered
Insulation (top layer)
: adhered
Insulation (bottom layer)
: adhered
Air/Vapour control layer
: self-adhered
Deck overlay (thermal barrier)
: mechanically fastened
Roof deck
SOP PARS 2-A
-2.9
-60
Soprema Inc.
View options
Sopralene Flam 180 GR
Sopralene Flam 250 GR
Soprastar Flam HD GR
Sopralene Mammouth GR
Sopraply Traffic Cap 560
Sopraply Traffic Cap FR 561
Soprafix Traffic Cap 660
Soprafix Traffic Cap FR 661
View options
Elastophene Flam
Sopralene Flam 180
Sopralene Flam 250
Sopraply Base 520
2
View options
Sopraboard
View options
Sopra-Iso Plus
ACFoam III (Atlas)
ENRGY 3 CGF (JM)
H-Shield CG (Hunter)
View options
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: mechanically fastened
Insulation (top layer)
: loose-laid
Insulation (bottom layer)
: loose-laid
Air/Vapour control layer
: self-adhered
Deck overlay (thermal barrier)
: optional (various securement methods)
Roof deck
SOP PARS 3-A
-1.4
-30
Soprema Inc.
View options
Sopralene Flam 180 GR
Sopralene Flam 250 GR
Soprastar Flam HD GR
Sopralene Mammouth GR
Sopraply Traffic Cap 560
Sopraply Traffic Cap FR 561
Soprafix Traffic Cap 660
Soprafix Traffic Cap FR 661
View options
Elastophene Flam
Sopralene Flam 180
Sopralene Flam 250
Sopraply Base 520
2
View options
Sopraboard
View options
Sopra-Iso Plus
ACFoam III (Atlas)
ENRGY 3 CGF (JM)
H-Shield CG (Hunter)
View options
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: mechanically fastened
Insulation (top layer)
: loose-laid
Insulation (bottom layer)
: loose-laid
Air/Vapour control layer
: self-adhered
Deck overlay (thermal barrier)
: optional (various securement methods)
Roof deck
SOP PARS 3-B
-2.3
-48
Soprema Inc.
View options
Sopralene Flam 180 GR
Sopralene Flam 250 GR
Soprastar Flam HD GR
Sopralene Mammouth GR
Sopraply Traffic Cap 560
Sopraply Traffic Cap FR 561
Soprafix Traffic Cap 660
Soprafix Traffic Cap FR 661
View options
Elastophene Flam
Sopralene Flam 180
Sopralene Flam 250
Sopraply Base 520
2
View options
Sopraboard
View options
Sopra-Iso Plus
ACFoam III (Atlas)
ENRGY 3 CGF (JM)
H-Shield CG (Hunter)
View options
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: mechanically fastened
Insulation (top layer)
: loose-laid
Insulation (bottom layer)
: loose-laid
Air/Vapour control layer
: self-adhered
Deck overlay (thermal barrier)
: optional (various securement methods)
Roof deck
SOP PARS 3-C
-2.8
-58
Soprema Inc.
View options
Sopralene Flam 180 GR
Sopralene Flam 250 GR
Soprastar Flam HD GR
Sopralene Mammouth GR
Sopraply Traffic Cap 560
Sopraply Traffic Cap FR 561
Soprafix Traffic Cap 660
Soprafix Traffic Cap FR 661
View options
Elastophene Flam
Sopralene Flam 180
Sopralene Flam 250
Sopraply Base 520
2
View options
Sopraboard
View options
Sopra-Iso Plus
ACFoam III (Atlas)
ENRGY 3 CGF (JM)
H-Shield CG (Hunter)
View options
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: mechanically fastened
Insulation (top layer)
: loose-laid
Insulation (bottom layer)
: loose-laid
Air/Vapour control layer
: self-adhered
Deck overlay (thermal barrier)
: optional (various securement methods)
Roof deck
SOP PARS 3-D
-3.4
-70
Soprema Inc.
View options
Sopralene Stick HR GR
View options
N/A (see Insulation Overlay)
2
View options
Soprasmart Board 180 (Sanded)
View options
Sopra-Iso Plus
SopraRock DD
SopraRock DD Plus
SopraRock MD
SopraRock MD Plus
ACFoam III (Atlas)
ENRGY 3 CGF (JM)
H-Shield CG (Hunter)
View options
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
View options
Steel
View summary
Cap membrane
: self-adhered
Base membrane
: N/A (see Insulation Overlay)
Insulation overlay
: mechanically fastened
Insulation (top layer)
: (optional) various securement options
Insulation (bottom layer)
: (optional) various securement options
Air/Vapour control layer
: (optional) various securement options
Deck overlay (thermal barrier)
: loose-laid or mechanically attached
Roof deck
SOP PARS 4-A
-1.8
-37
Soprema Inc.
View options
Sopralene Stick HR GR
View options
N/A (see Insulation Overlay)
2
View options
Soprasmart Board 180 (Sanded)
View options
Sopra-Iso Plus
SopraRock DD
SopraRock DD Plus
SopraRock MD
SopraRock MD Plus
ACFoam III (Atlas)
ENRGY 3 CGF (JM)
H-Shield CG (Hunter)
View options
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
View options
Steel
View summary
Cap membrane
: self-adhered
Base membrane
: N/A (see Insulation Overlay)
Insulation overlay
: mechanically fastened
Insulation (top layer)
: (optional) various securement options
Insulation (bottom layer)
: (optional) various securement options
Air/Vapour control layer
: (optional) various securement options
Deck overlay (thermal barrier)
: loose-laid or mechanically attached
Roof deck
SOP PARS 4-B
-3
-62
Soprema Inc.
View options
Sopralene Stick HR GR
View options
Elastophene Flam
Sopralene Flam 180
Sopralene Flam 250
Sopraply Base 520
2
View options
Soprasmart Board 180 (Sanded)
View options
Sopra-Iso Plus
SopraRock DD
SopraRock DD Plus
SopraRock MD
SopraRock MD Plus
ACFoam III (Atlas)
ENRGY 3 CGF (JM)
H-Shield CG (Hunter)
View options
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
View options
Steel
View summary
Cap membrane
: self-adhered
Base membrane
: N/A (see Insulation Overlay)
Insulation overlay
: mechanically fastened
Insulation (top layer)
: (optional) various securement options
Insulation (bottom layer)
: (optional) various securement options
Air/Vapour control layer
: (optional) various securement options
Deck overlay (thermal barrier)
: loose-laid or mechanically attached
Roof deck
SOP PARS 5-A
-2.2
-45
Soprema Inc.
View options
Sopralene Flam 180 GR
Sopralene Flam 250 GR
Soprastar Flam HD GR
Sopralene Mammouth GR
Sopraply Traffic Cap 560
Sopraply Traffic Cap FR 561
View options
Elastophene Flam
Sopralene Flam 180
Sopralene Flam 250
Sopraply Base 520
2
View options
Optional (none listed)
View options
Sopra-Iso Plus
SopraRock DD
SopraRock DD Plus
SopraRock MD
SopraRock MD Plus
ACFoam III (Atlas)
ENRGY 3 CGF (JM)
H-Shield CG (Hunter)
View options
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: (optional) none listed*
Insulation (top layer)
: mechanically fastened
Insulation (bottom layer)
: loose-laid
Air/Vapour control layer
: various securement options
Deck overlay (thermal barrier)
: mechanically fastened
Roof deck
* Insulation requires an adhered overlay to comply with RoofStar Guarantee Standards
SOP PARS 5-B
-3.6
-75
Soprema Inc.
View options
Sopralene Flam 180 GR
Sopralene Flam 250 GR
Soprastar Flam HD GR
Sopralene Mammouth GR
Sopraply Traffic Cap 560
Sopraply Traffic Cap FR 561
View options
Elastophene Flam
Sopralene Flam 180
Sopralene Flam 250
Sopraply Base 520
2
View options
Optional (none listed)
View options
Sopra-Iso Plus
SopraRock DD
SopraRock DD Plus
SopraRock MD
SopraRock MD Plus
ACFoam III (Atlas)
ENRGY 3 CGF (JM)
H-Shield CG (Hunter)
View options
DensDeck® Prime with EONIC Roof Board
DensDeck® Roofboard
Securerock Gypsum Fibre Roof Board
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: (optional) none listed*
Insulation (top layer)
: mechanically fastened
Insulation (bottom layer)
: loose-laid
Air/Vapour control layer
: various securement options
Deck overlay (thermal barrier)
: mechanically fastened
Roof deck
* Insulation requires an adhered overlay to comply with RoofStar Guarantee Standards
SOP PARS 5-C
-5
-105
Soprema Inc.
View options
Sopralene Flam 250 GR
View options
N/A (see Insulation Overlay)
2
View options
Soprasmart Board 180
View options
No Accepted Material: Consult manufacturer
View options
DensDeck® Prime with EONIC Roof Board
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: N/A (see Insulation Overlay)
Insulation overlay
: adhered
Insulation (top layer)
: adhered
Insulation (bottom layer)
: N/A (various securment options)
Air/Vapour control layer
: self-adhered
Deck overlay (thermal barrier)
: mechanically fastened
Roof deck
SOP PARS 6-A
-5.6
-117
Soprema Inc.
View options
Sopralene Flam 250 GR
View options
Sopralene Flam 180
2
View options
DensDeck® Prime with EONIC Roof Board
View options
No Accepted Material: Consult manufacturer
View options
N/A
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: mechanically fastened
Insulation (top layer)
: loose-laid
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: self-adhered
Deck overlay (thermal barrier)
: N/A
Roof deck
SOP PARS 7-A
-1.9
-40
Soprema Inc.
View options
Sopralene Flam 250 GR
View options
N/A (see Insulation Overlay)
2
View options
Soprasmart Board 180
View options
No Accepted Material: Consult manufacturer
View options
N/A
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: N/A (see Insulation Overlay)
Insulation overlay
: adhered
Insulation (top layer)
: loose-laid
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: torch-applied
Deck overlay (thermal barrier)
: N/A
Roof deck
SOP PARS 8-A
-3.6
-75
Soprema Inc.
View options
Sopralene Flam 250 GR
View options
Sopralene Flam 180
2
View options
Sopraboard
View options
No Accepted Material: Consult manufacturer
View options
N/A
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: mechanically fastened
Insulation (top layer)
: loose-laid
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: self-adhered
Deck overlay (thermal barrier)
: N/A
Roof deck
SOP PARS 9-A
-1.8
-37
Soprema Inc.
View options
Sopralene Flam 250 GR
View options
Sopralene Flam 180
2
View options
Sopraboard
View options
No Accepted Material: Consult manufacturer
View options
N/A
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: mechanically fastened
Insulation (top layer)
: loose-laid
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: self-adhered
Deck overlay (thermal barrier)
: N/A
Roof deck
SOP PARS 10-A
-5.7
-120
Soprema Inc.
View options
Sopralene Flam 250 GR
View options
Sopralene Flam 180
2
View options
Sopraboard
View options
No Accepted Material: Consult manufacturer
View options
N/A
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: adhered
Insulation (top layer)
: adhered
Insulation (bottom layer)
: mechanically fastened
Air/Vapour control layer
: self-adhered
Deck overlay (thermal barrier)
: N/A
Roof deck
SOP PARS 11-A
-2.4
-50
Soprema Inc.
View options
Colply Traffic Cap 460
View options
Elastophene S
2
View options
No Accepted Material: Consult manufacturer
View options
No Accepted Material: Consult manufacturer
View options
Optional
View options
Steel
View summary
Cap membrane
: hot-mopped bith bitumen
Base membrane
: hot-mopped with bitumen
Insulation overlay
: hot-mopped with bitumen
Insulation (top layer)
: hot-mopped bith bitumen
Insulation (bottom layer)
: mechanically fastened
Air/Vapour control layer
: hot-mopped bith bitumen
Deck overlay (thermal barrier)
: (optional) various securement options
Roof deck
SOP PARS 12-A
-3.6
-75
Soprema Inc.
View options
Sopralene Flam 250 GR
View options
Sopralene Flam 180
2
View options
DensDeck® Prime with EONIC Roof Board
View options
No Accepted Material: Consult manufacturer
View options
DensDeck® Prime with EONIC Roof Board
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: adhered
Insulation (top layer)
: adhered
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: self-adhered
Deck overlay (thermal barrier)
: mechanically fastened
Roof deck
SOP PARS 13-A
-2.3
-48
Soprema Inc.
View options
Colply Traffic Cap 860
View options
Colvent Base 830
2
View options
N/A
View options
Sopra-Iso Plus
Not an Accepted Material (bottom layer): Consult manufacturer
View options
DensDeck® Prime with EONIC Roof Board
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: self-adhered
Insulation overlay
: N/A
Insulation (top layer)
: adhered
Insulation (bottom layer)
: adhered
Air/Vapour control layer
: torch-applied
Deck overlay (thermal barrier)
: mechanically fastened
Roof deck
SOP PARS 14-A
-3.2
-67
Soprema Inc.
View options
Sopralene Stick HR 20
Sopralene Stick HR 40
View options
N/A (see Insulation Overlay)
2
View options
Soprasmart Board 180 (sanded)
View options
Optional
View options
N/A
View options
Plywood
View summary
Cap membrane
: self-adhered
Base membrane
: N/A (see Insulation Overlay)
Insulation overlay
: mechanically fastened
Insulation (top layer)
: (optional) various securement options
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: (optional) various securement options
Deck overlay (thermal barrier)
: (optional) various securement options
Roof deck
SOP PARS 15-A
-1.8
-37
Soprema Inc.
View options
Sopralene Stick HR 20
Sopralene Stick HR 40
View options
N/A (see Insulation Overlay)
2
View options
Soprasmart Board 180 (sanded)
View options
Optional
View options
N/A
View options
Plywood
View summary
Cap membrane
: self-adhered
Base membrane
: N/A (see Insulation Overlay)
Insulation overlay
: mechanically fastened
Insulation (top layer)
: (optional) various securement options
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: (optional) various securement options
Deck overlay (thermal barrier)
: (optional) various securement options
Roof deck
SOP PARS 15-B
-3
-62
Soprema Inc.
View options
Colvent Traffic Cap 860
View options
Colvent Base 830
2
View options
N/A
View options
Sopra-Iso Plus
Not an Accepted Material (bottom layer): Consult manufacturer
View options
DensDeck® Prime with EONIC Roof Board
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: self-adhered
Insulation overlay
: N/A
Insulation (top layer)
: adhered
Insulation (bottom layer)
: adhered
Air/Vapour control layer
: torch-applied
Deck overlay (thermal barrier)
: mechanically fastened
Roof deck
SOP PARS 16-A
-4
-83
Soprema Inc.
View options
Sopralene Flam 250 GR
View options
Sopralene Flam 180
2
View options
DensDeck® Prime with EONIC Roof Board
View options
No Accepted Material: Consult manufacturer
View options
N/A
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: mechanically fastened
Insulation (top layer)
: loose-laid
Insulation (bottom layer)
: N/A
Air/Vapour control layer
: self-adhered
Deck overlay (thermal barrier)
: N/A
Roof deck
SOP PARS 17-A
-2.9
-60
Soprema Inc.
View options
Sopralene Flam 250 GR
View options
Sopralene Flam 180
2
View options
DensDeck® Prime with EONIC Roof Board
View options
No Accepted Material: Consult manufacturer
View options
DensDeck® Prime with EONIC Roof Board
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: adhered
Insulation (top layer)
: adhered
Insulation (bottom layer)
: adhered
Air/Vapour control layer
: self-adhered
Deck overlay (thermal barrier)
: mechanically fastened
Roof deck
SOP PARS 18-A
-4
-83
Soprema Inc.
View options
Sopralene Flam 250 GR
View options
Sopralene Flam 180
2
View options
DensDeck® Prime with EONIC Roof Board
View options
No Accepted Material: Consult manufacturer
View options
DensDeck® Prime with EONIC Roof Board
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: adhered
Insulation (top layer)
: adhered
Insulation (bottom layer)
: adhered
Air/Vapour control layer
: torch-applied
Deck overlay (thermal barrier)
: mechanically fastened
Roof deck
SOP PARS 19-A
-5.7
-120
Soprema Inc.
View options
Sopralene Flam 180 GR
Sopralene Flam 250 GR
Soprastar Flam HD GR
Sopralene Mammouth GR
Sopraply Traffic Cap 560
Sopraply Traffic Cap FR 561
View options
Elastophene Flam
Sopralene Flam 180
Sopralene Flam 250
Sopraply Base 520
2
View options
Optional (none listed)
View options
Sopra-Iso Plus
SopraRock DD
SopraRock DD Plus
SopraRock MD
SopraRock MD Plus
ACFoam III (Atlas)
ENRGY 3 CGF (JM)
H-Shield CG (Hunter)
View options
Securerock Gypsum Fibre Roof Board
View options
Steel
View summary
Cap membrane
: torch-applied
Base membrane
: torch-applied
Insulation overlay
: adhered
Insulation (top layer)
: adhered
Insulation (bottom layer)
: adhered
Air/Vapour control layer
: torch-applied
Deck overlay (thermal barrier)
: mechanically fastened
Roof deck
SOP PARS 20-A
-2.9
-60