Table Drafts 4
Table Drafts 4
Revision as of 21:47, 11 December 2020 by James Klassen (talk | contribs) (→Part 9: TPO Table (Combined 5, 10, 15))
1 Part 9: EPDM Table (Combined 5, 10, 15)
Exposed Roof Systems | Protected Roof Systems | Grade-level Water- proofing | |||||||
---|---|---|---|---|---|---|---|---|---|
Conventionally Insulated / Uninsulated Systems | Built-in Gutters |
Ballasted | PMR Systems | ||||||
Mechanically Fastened or Induction Welded* |
Self-adhered | Adhered or Hot-mopped |
Adhered or Self-adhered |
Loose-laid | Self-adhered, Adhered or Hot-mopped |
Self-adhered, Adhered or Hot-mopped | |||
Type, Reinforcement, Grade | Guarantee Term | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | |
EPDM (reinforced) | |||||||||
5 | 1.524 (60) | 1.524 (60) | 1.143 (45) | 1.524 (60) | 1.143 (45) | 1.143 (45) | |||
10 | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | |||
15 | 2.286 (90) | 1.524 (60) | |||||||
EPDM (unreinforced) | |||||||||
5 | 1.524 (60) | 1.143 (45) | 1.524 (60) | 1.143 (45) | 1.143 (45) | ||||
10 | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | ||||
15 | 2.286 (90) | 2.286 (90) | 2.286 (90) |
- *Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.
2 Part 9: TPO Table (Combined 5, 10, 15)
Exposed Roof Systems | Protected Roof Systems | Grade-level Water- proofing | |||||||
---|---|---|---|---|---|---|---|---|---|
Conventionally Insulated / Uninsulated Systems | Built-in Gutters |
Ballasted | PMR Systems | ||||||
Mechanically Fastened or Induction Welded* |
Self-adhered | Adhered or Hot-mopped |
Adhered or Self-adhered |
Loose-laid | Self-adhered, Adhered or Hot-mopped |
Self-adhered, Adhered or Hot-mopped | |||
Type, Reinforcement, Grade | Guarantee Term | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | |
TPO | |||||||||
5 | 1.143 (45) | 1.524 (60) | 1.143 (45) | 1.524 (60) | 1.143 (45) | 1.143 (45) | |||
10 | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | |||
15 | 2.032 (80) | 2.032 (80) | 2.032 (80) | 2.032 (80) |
- *Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.
3 Part 9: PVC Table (Combined 5, 10, 15)
Exposed Roof Systems | Protected Roof Systems | Grade-level Water- proofing | |||||||
---|---|---|---|---|---|---|---|---|---|
Conventionally Insulated / Uninsulated Systems | Built-in Gutters |
Ballasted | PMR Systems | ||||||
Mechanically Fastened or Induction Welded* |
Self-adhered | Adhered or Hot-mopped |
Adhered or Self-adhered |
Loose-laid | Self-adhered, Adhered or Hot-mopped |
Self-adhered, Adhered or Hot-mopped | |||
Type, Reinforcement, Grade | Guarantee Term | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | |
PVC | |||||||||
5 | xxxx | xxxx | xxxx | xxxx | xxxx | xxxx | xxxx | ||
10 | xxxx | xxxx | xxxx | xxxx | xxxx | xxxx | xxxx | ||
15 | xxxx | xxxx | xxxx | xxxx | xxxx | xxxx | xxxx |
- *Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.