About the Tables

The tables on the adjacent tabs display data drawn from, and links to, Tested Assembly Reports listed by the membrane type shown on the tab. Dynamic Wind Uplift (DUR) values are shown in columns near the left side of the tables. Only the DUR and Manufacturer columns are sortable; to sort a column, click the column heading.

Each row displays one test for a particular system of securement. That means that the DUR derived for that test is based on a particular pattern of fasteners or adhesive application. Most assemblies were tested with one system of securement, but some were tested with as many as four. When this is the case, the same report number will be displayed with test report names such as IKO MARS 1-A and IKO MARS 1-B. Read the test report details to see what was changed in the securement system that affected the DUR for the assembly.

Table Structure and Organization

Every table displays Tested Assembly report data in easy-to-read rows with drop-down buttons that display key information for each assembly (see the "try me" example below). The sample below illustrates the layout and functionality of the tables:

When the Tested Assembly uses a membrane with 2 or more plies, each membrane and its options is listed in separate columns.

Tested Assembly Report Data RoofStar
Guarantee
Primary Materials Other System Materials & Deck
Manufacturer Dynamic Uplift Resistance Roof
Assembly
Summary
Test Report Term Cap
Membrane
Base
Membrane
Plies Insulation
Overlay
Insulation Deck
Overlay
Deck
Type
kPa Psf
Manufacturer KPA PSF Report link 5, 10 1, 2 or 3 Deck type

Note that some tests were conducted without one or more of these constituent components and may list those materials as "optional". When a material category such as "insulation overlay" is absent from the test, the drop-down menu will indicate its absence with "N/A" or as "optional". Occasionally, a missing material poses a conflict with the RoofStar Guarantee Standards. When the conflict is obvious, the Roof Assembly Summary will normally flag this with a note at the bottom of the list. Notwithstanding these notes, the reader is responsible to understand and apply the RoofStar Guarantee Standards regardless of the Tested Assembly report (see below under Tested Assemblies and RoofStar Guarantee Standards).

The Roof Assembly Summary provides a quick overview of how the roof assembly is secured. This feature of the tables will be especially helpful when searching for a suitable PARS assembly, because the placement of mechanical fasteners can vary widely. Note, however, that the summaries do not list sizes, types or spacing of specific adhesives or fasteners; these details must be obtained from a careful reading of the Tested Assembly report.

Tested Assembly Report Data Primary Materials Other System Materials & Deck
Manufacturer Dynamic Uplift Resistance Roof
Assembly
Summary
Test Report Cap
Membrane
Base
Membrane
Plies Insulation
Overlay
Insulation Deck
Overlay
Deck
Type
kPa Psf
Click arrows to sort
IKO Industries Ltd. -1.9 -40 IKO MARS 1-A
2
Steel
IKO Industries Ltd. -4.8 -100 IKO MARS 1-B
2
Steel
IKO Industries Ltd. -2.4 -50 IKO MARS 2-A
2
Steel
IKO Industries Ltd. -3.4 -70 IKO MARS 2-B
2
Steel
IKO Industries Ltd. -5.1 -106 IKO MARS 2-C
2
Steel
IKO Industries Ltd. -2.9 -60 IKO MARS 3-A 2
Steel
IKO Industries Ltd. -3.4 -70 IKO MARS 3-B 2
Steel
IKO Industries Ltd. -6.6 -138 IKO MARS 3-C 2
Steel
IKO Industries Ltd. -4.8 -100 IKO MARS 3-D 2
Steel
IKO Industries Ltd. -5.4 -112 IKO MARS 4-A
2
Steel
Soprema Inc. -1.8 -37 SOP MARS 1-A 2 Steel
Soprema Inc. -2.3 -47 SOP MARS 1-B 2 Steel
Soprema Inc. -3.4 -70 SOP MARS 1-C 2 Steel
Soprema Inc. -2.4 -50 SOP MARS 2-A 2 Steel
Soprema Inc. -3.4 -70 SOP MARS 2-B 2 Steel
Soprema Inc. -5.2 -108 SOP MARS 2-C 2 Steel
Soprema Inc. -2 -42 SOP MARS 3-A
2 Steel
Soprema Inc. -2.4 -50 SOP MARS 3-B
2 Steel
Soprema Inc. -3.4 -70 SOP MARS 3-C
2 Steel
Soprema Inc. -6.2 -130 SOP MARS 3-D
2 Steel
Soprema Inc. -2.4 -50 SOP MARS 4-A
2 Plywood
16mm (5/8")
Soprema Inc. -1.6 -33 SOP MARS 5-A
2 Plywood
16mm (5/8")
Soprema Inc. -1.9 -40 SOP MARS 5-B
2 Plywood
16mm (5/8")
Soprema Inc. -3.2 -67 SOP MARS 5-C
2 Plywood
16mm (5/8")
Soprema Inc. -2.4 -50 SOP MARS 6-A 2 Steel
Soprema Inc. -3.4 -70 SOP MARS 6-B 2 Steel
Soprema Inc. -5.2 -108 SOP MARS 6-C 2 Steel
Soprema Inc. -2 -41 SOP MARS 7-A 1 Steel
Soprema Inc. -2.9 -60 SOP MARS 7-B 1 Steel
Soprema Inc. -4 -84 SOP MARS 7-C 1 Steel
Soprema Inc. -5.2 -108 SOP MARS 7-D 1 Steel
Soprema Inc. -1.9 -40 SOP MARS 8-A 2 Steel
Soprema Inc. -3.2 -67 SOP MARS 8-B 2 Steel
Soprema Inc. -4.8 -100 SOP MARS 8-C 2 Steel
Soprema Inc. -1.8 -37 SOP MARS 9-A 2
Steel
Soprema Inc. -2.4 -50 SOP MARS 9-B 2
Steel
Soprema Inc. -2 -42 SOP MARS 10-A
2
Steel
Soprema Inc. -2.4 -50 SOP MARS 10-B
2
Steel
Soprema Inc. -3.3 -70 SOP MARS 10-C
2
Steel
Soprema Inc. -6.2 -130 SOP MARS 10-D
2
Steel
Soprema Inc. -1.9 -40 SOP MARS 11-A 2 Steel
Soprema Inc. -3.2 -67 SOP MARS 11-B 2 Steel
Soprema Inc. -4.8 -100 SOP MARS 11-C 2 Steel
Soprema Inc. -2.4 -50 SOP MARS 12-A 2 Steel
Soprema Inc. -3.4 -70 SOP MARS 12-B 2 Steel
Soprema Inc. -5.2 -108 SOP MARS 12-C 2 Steel
Soprema Inc. -1.8 -37 SOP MARS 13-A 2 Steel
Soprema Inc. -2.4 -50 SOP MARS 13-B 2 Steel
Soprema Inc. -2 -41 SOP MARS 14-A 1 Steel
Soprema Inc. -2.9 -60 SOP MARS 14-B 1 Steel
Soprema Inc. -4 -84 SOP MARS 14-C 1 Steel
Soprema Inc. -5.2 -108 SOP MARS 14-D 1 Steel
Soprema Inc. -1.6 -33 SOP MARS 15-A
2
Plywood
16mm (5/8")
Soprema Inc. -1.9 -40 SOP MARS 15-B
2
Plywood
16mm (5/8")
Soprema Inc. -3.2 -67 SOP MARS 15-C
2
Plywood
16mm (5/8")
Tested Assembly Report Data Primary Materials Other System Materials & Deck
Manufacturer Dynamic Uplift Resistance Roof
Assembly
Summary
Test Report Membrane Plies Insulation
Overlay
Insulation Deck
Overlay
Deck
Type
kPa Psf
Carlisle Syntec Systems Canada -3.4 -70 CAR MARS 3-A 1 Steel
Carlisle Syntec Systems Canada -3.4 -71 CAR MARS 4-A 1 Steel
Elevate (formerly Firestone) -3.2 -67 FIR MARS 3-A 1
Steel
Elevate (formerly Firestone) -3.8 -80 FIR MARS 4-A 1
Steel
Elevate (formerly Firestone) -4.2 -87 FIR MARS 4-B 1
Steel
Elevate (formerly Firestone) -3.8 -80 FIR MARS 5-A 1
Steel
Elevate (formerly Firestone) -3 -63 FIR MARS 6-A 1
Steel
IKO Industries Ltd. -7.2 -150 IKO-MARS 5-A 1
Steel
IKO Industries Ltd. -5 -105 IKO-MARS 6-A 1
Steel
IKO Industries Ltd. -3.6 -75 IKO-MARS 7-A 1
Steel
IKO Industries Ltd. -5.7 -120 IKO-MARS 8-A 1
Steel
IKO Industries Ltd. -4.2 -87.5 IKO-MARS 9-A 1
Steel
IKO Industries Ltd. -4.8 -100 IKO-MARS 10-A 1
Steel
IKO Industries Ltd. -1.91 -40 IKO-MARS 11-A
1
Steel
IKO Industries Ltd. -2.9 -61 IKO-MARS 12-A
1
Steel
IKO Industries Ltd. -3.45 -72 IKO-MARS 13-A 1
Steel
IKO Industries Ltd. -2.7 -56.6 IKO-MARS 14-A
1
Steel
IKO Industries Ltd. -2.28 -47.5 IKO-MARS 15-A 1
Steel
Johns Manville Corp. -3.6 -75 JM MARS 3-A 1
Steel
Johns Manville Corp. -5 -105 JM MARS 4-A 1
Steel
Tested Assembly Report Data Primary Materials Other System Materials & Deck
Manufacturer Dynamic Uplift Resistance Roof
Assembly
Summary
Test Report Membrane Plies Insulation
Overlay
Insulation Deck
Overlay
Deck
Type
kPa Psf
Carlisle Syntec Systems Canada -3.4 -70 CAR MARS 1-A 1 Steel
Carlisle Syntec Systems Canada -2.3 -47 CAR MARS 2-A 1 Steel
Johns Manville Corp. -3.6 -75 JM AARS 1-A 1
Steel
Johns Manville Corp. -3.6 -75 JM AARS 2-A 1
Steel

2 PARS

About the Tables

The tables on the adjacent tabs display data drawn from, and links to, Tested Assembly Reports listed by the membrane type shown on the tab. Dynamic Wind Uplift (DUR) values are shown in columns near the left side of the tables. Only the DUR and Manufacturer columns are sortable; to sort a column, click the column heading.

Each row displays one test for a particular system of securement. That means that the DUR derived for that test is based on a particular pattern of fasteners or adhesive application. Most assemblies were tested with one system of securement, but some were tested with as many as four. When this is the case, the same report number will be displayed with test report names such as IKO MARS 1-A and IKO MARS 1-B. Read the test report details to see what was changed in the securement system that affected the DUR for the assembly.

Table Structure and Organization

Every table displays Tested Assembly report data in easy-to-read rows with drop-down buttons that display key information for each assembly (see the "try me" example below). Each button displays one or more options for

  • roof membrane
  • insulation overlay
  • insulation panels and
  • the deck overlay.


When the Tested Assembly uses a membrane with 2 or more plies, they are displayed in separate columns.

Try me

Deck types tested with the Assembly are shown in the far right column.

Some tests were conducted without one or more of these constituent components and may list those materials as "optional". When a material category such as "insulation overlay" is absent from the test, the drop-down menu will indicate its absence with "N/A" or as "optional". Occasionally, a missing material poses a conflict with the RoofStar Guarantee Standards. When the conflict is obvious, the Roof Assembly Summary will normally flag this with a note at the bottom of the list. Notwithstanding these notes, the reader is responsible to understand and apply the RoofStar Guarantee Standards regardless of the Tested Assembly report (see below under Tested Assemblies and RoofStar Guarantee Standards).

The Roof Assembly Summary provides a quick overview of how the roof assembly is secured. This feature of the tables will be especially helpful when searching for a suitable PARS assembly, because the placement of mechanical fasteners can vary widely. Note, however, that the summaries do not list sizes, types or spacing of specific adhesives or fasteners; these details must be obtained from a careful reading of the Tested Assembly report.

Tested Assembly Report Data Primary Materials Other System Materials & Deck
Manufacturer Dynamic Uplift Resistance Roof
Assembly
Summary
Test Report Cap
Membrane
Base
Membrane
Plies Insulation
Overlay
Insulation Deck
Overlay
Deck
Type
kPa Psf
Click arrows to sort
Elevate (formerly Firestone) -2.1 -45 FIR PARS 1-A 2
Steel
Garland Canada Inc. -2.2 -46 GAR PARS 1-A 2
Steel
Garland Canada Inc. -2.2 -46 GAR PARS 2-A 2
Steel
Garland Canada Inc. -2.2 -46 GAR PARS 3-A 2
Steel
Henry Company Canada -4.67 -97.5 HEN PARS 1-A
2
Steel
IKO Industries Ltd. -1.4 -29.0 IKO PARS 1-A 2
Steel
IKO Industries Ltd. -2.3 -48.0 IKO PARS 2-A 2
Steel
IKO Industries Ltd. -1.8 -37.5 IKO PARS 3-A 2
Steel
IKO Industries Ltd. -3.6 -75 IKO PARS 4-A 2
Steel
IKO Industries Ltd. -3 -62 IKO PARS 5-A 2
Steel
IKO Industries Ltd. -2.4 -50 IKO PARS 6-A 2
Steel
IKO Industries Ltd. -1.4 -30 IKO PARS 7-A 2
Steel
IKO Industries Ltd. -2.4 -50 IKO PARS 8-A 2
Steel
IKO Industries Ltd. -2.4 -50 IKO PARS 9-A 2
Steel
IKO Industries Ltd. -2.2 -47 IKO PARS 13-A 2
Steel
IKO Industries Ltd. -4.2 -80 IKO PARS 14-A 2
Steel
IKO Industries Ltd. -1.9 -40 IKO PARS 15-A 2
Steel
IKO Industries Ltd. -1.9 -40 IKO PARS 16-A 2
Steel
IKO Industries Ltd. -6.7 -140 IKO PARS 17-A 2
Steel
IKO Industries Ltd. -3.0 -62 IKO PARS 18-A
2
Steel
IKO Industries Ltd. -3.6 -75 IKO PARS 19-A 2
Steel
IKO Industries Ltd. -4.1 -85 IKO PARS 20-A 2
Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 1-A 2 or 3
Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 2-A 2 or 3
Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 3-A 2 or 3 Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 4-A 2 or 3 Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 5-A 2 or 3 Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 6-A 2 or 3 Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 7-A 2 or 3 Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 8-A 2 or 3
Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 9-A 2 or 3
Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 10-A 2 or 3
Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 11-A 2 or 3
Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 12-A 2 or 3 Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 13-A 2 or 3
Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 14-A 2 or 3 Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 15-A 2 or 3
Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 15-A 2 or 3 Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 17-A 2 or 3 Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 18-A 2 or 3 Steel
Polyglass USA, Inc. -3.4 -70 POL PARS 19-A 2 or 3 Steel
Polyglass USA, Inc. -1.4 -30 POL PARS 20-A 2 or 3
Steel
Polyglass USA, Inc. -1.8 -38 POL PARS 21-A 2 or 3
Steel
Polyglass USA, Inc. -3.4 -72 POL PARS 22-A 2 or 3 Steel
Polyglass USA, Inc. -3.4 -72 POL PARS 23-A 2 or 3 Steel
Siplast, Inc. -1.9 -40 SIP PARS 1-A
2
Steel
Siplast, Inc. -1.4 -30 SIP PARS 2-A
2
Plywood
16mm (5/8")
Siplast, Inc. -2.23 -46.67 SIP PARS 3-A
2
Steel
Siplast, Inc. -1.8 -37 SIP PARS 4-A
2
Steel
Siplast, Inc. -2.86 -60 SIP PARS 5-A
2
Steel
Siplast, Inc. -2.9 -60 SIP PARS 6-A
2
Steel
Siplast, Inc. -1.46 -30 SIP PARS 7-A
2
Steel
Siplast, Inc. -2.9 -60 SIP PARS 8-A 2
Steel
Siplast, Inc. -2.9 -60 SIP PARS 9-A 2 Steel
Siplast, Inc. -2.3 -47 SIP PARS 10-A 2
Plywood
16mm (5/8")
Siplast, Inc. -3.7 -77 SIP PARS 11-A 2 Plywood
16mm (5/8")
Siplast, Inc. -2.5 -53 SIP PARS 12-A 2
Plywood
16mm (5/8")
Siplast, Inc. -3.5 -73 SIP PARS 13-A 2
Steel
Siplast, Inc. -2 -42 SIP PARS 14-A
2 Steel
Siplast, Inc. -1.8 -38 SIP PARS 15-A 2
Steel
Soprema Inc. -1.4 -30 SOP PARS 1-A 2
Steel
Soprema Inc. -2.3 -48 SOP PARS 1-B 2
Steel
Soprema Inc. -2.8 -58 SOP PARS 1-C 2
Steel
Soprema Inc. -2.9 -60 SOP PARS 2-A 2
Steel
Soprema Inc. -1.4 -30 SOP PARS 3-A 2
Steel
Soprema Inc. -2.3 -48 SOP PARS 3-B 2
Steel
Soprema Inc. -2.8 -58 SOP PARS 3-C 2
Steel
Soprema Inc. -3.4 -70 SOP PARS 3-D 2
Steel
Soprema Inc. -1.8 -37 SOP PARS 4-A 2 Steel
Soprema Inc. -3 -62 SOP PARS 4-B 2 Steel
Soprema Inc. -2.2 -45 SOP PARS 5-A 2 Steel
Soprema Inc. -3.6 -75 SOP PARS 5-B 2 Steel
Soprema Inc. -5 -105 SOP PARS 5-C 2 Steel
Soprema Inc. -5.6 -117 SOP PARS 6-A
2
Steel
Soprema Inc. -1.9 -40 SOP PARS 7-A
2
Steel
Soprema Inc. -3.6 -75 SOP PARS 8-A
2
Steel
Soprema Inc. -1.8 -37 SOP PARS 9-A
2
Steel
Soprema Inc. -5.7 -120 SOP PARS 10-A
2
Steel
Soprema Inc. -2.4 -50 SOP PARS 11-A
2
Steel
Soprema Inc. -3.6 -75 SOP PARS 12-A
2 Steel
Soprema Inc. -2.3 -48 SOP PARS 13-A
2 Steel
Soprema Inc. -3.2 -67 SOP PARS 14-A
2
Steel
Soprema Inc. -1.8 -37 SOP PARS 15-A 2
Plywood
16mm (5/8")
Soprema Inc. -3 -62 SOP PARS 15-B 2
Plywood
16mm (5/8")
Soprema Inc. -4 -83 SOP PARS 16-A
2
Steel
Soprema Inc. -2.9 -60 SOP PARS 17-A
2
Steel
Soprema Inc. -4 -83 SOP PARS 18-A
2 Steel
Soprema Inc. -5.7 -120 SOP PARS 19-A
2 Steel
Soprema Inc. -2.9 -60 SOP PARS 20-A 2
Steel
Soprema Inc. -1.9 -40 SOP PARS 21-A
2
Steel
Soprema Inc. -2.9 -60 SOP PARS 21-B
2
Steel
Soprema Inc. -3.9 -81 SOP PARS 22-A
2 Steel
Soprema Inc. -2.9 -60 SOP PARS 23-A
2
Steel
Tested Assembly Report Data Primary Materials Other System Materials & Deck
Manufacturer Dynamic Uplift Resistance Roof
Assembly
Summary
Test Report Membrane Plies Insulation
Overlay
Insulation Deck
Overlay
Deck
Type
kPa Psf
Carlisle Syntec Systems Canada -1.8 -37.5 CAR PARS 1-A 1
Steel
Elevate (formerly Firestone) -2.1 -45 FIR PARS 2-A 1
Steel
Elevate (formerly Firestone) -3.2 -67 FIR PARS 3-A 1
Steel
Tested Assembly Report Data Primary Materials Other System Materials & Deck
Manufacturer Dynamic Uplift Resistance Roof
Assembly
Summary
Test Report Membrane Plies Insulation
Overlay
Insulation Deck
Overlay
Deck
Type
kPa Psf
Carlisle Syntec Systems Canada -1.7 -35 CAR PARS 3-A 1
Steel
Elevate (formerly Firestone) -2.9 -60 FIR PARS 4-A 1
Steel
Elevate (formerly Firestone) -3.2 -67 FIR PARS 5-A 1
Steel
IKO Industries Ltd. -4.9 -100 IKO-PARS 21-A 1
Steel
IKO Industries Ltd. -3.4 -70 IKO-PARS 22-A 1
Steel
IKO Industries Ltd. -4.9 -100 IKO-PARS 23-A 1
Steel
Tested Assembly Report Data Primary Materials Other System Materials & Deck
Manufacturer Dynamic Uplift Resistance Roof
Assembly
Summary
Test Report Membrane Plies Insulation
Overlay
Insulation Deck
Overlay
Deck
Type
kPa Psf
IKO Industries Ltd. -3.6 -75 IKO PARS 10-A 4
Steel
IKO Industries Ltd. -2.9 -60 IKO PARS 11-A 4
Steel

3 AARS

About the Tables

The tables on the adjacent tabs display data drawn from, and links to, Tested Assembly Reports listed by the membrane type shown on the tab. Dynamic Wind Uplift (DUR) values are shown in columns near the left side of the tables. Only the DUR and Manufacturer columns are sortable; to sort a column, click the column heading.

Each row displays one test for a particular system of securement. That means that the DUR derived for that test is based on a particular pattern of fasteners or adhesive application. Most assemblies were tested with one system of securement, but some were tested with as many as four. When this is the case, the same report number will be displayed with test report names such as IKO MARS 1-A and IKO MARS 1-B. Read the test report details to see what was changed in the securement system that affected the DUR for the assembly.

Table Structure and Organization

Every table displays Tested Assembly report data in easy-to-read rows with drop-down buttons that display key information for each assembly (see the "try me" example below). Each button displays one or more options for

  • roof membrane
  • insulation overlay
  • insulation panels and
  • the deck overlay.


When the Tested Assembly uses a membrane with 2 or more plies, they are displayed in separate columns.

Try me

Deck types tested with the Assembly are shown in the far right column.

Some tests were conducted without one or more of these constituent components and may list those materials as "optional". When a material category such as "insulation overlay" is absent from the test, the drop-down menu will indicate its absence with "N/A" or as "optional". Occasionally, a missing material poses a conflict with the RoofStar Guarantee Standards. When the conflict is obvious, the Roof Assembly Summary will normally flag this with a note at the bottom of the list. Notwithstanding these notes, the reader is responsible to understand and apply the RoofStar Guarantee Standards regardless of the Tested Assembly report (see below under Tested Assemblies and RoofStar Guarantee Standards).

The Roof Assembly Summary provides a quick overview of how the roof assembly is secured. This feature of the tables will be especially helpful when searching for a suitable PARS assembly, because the placement of mechanical fasteners can vary widely. Note, however, that the summaries do not list sizes, types or spacing of specific adhesives or fasteners; these details must be obtained from a careful reading of the Tested Assembly report.

Tested Assembly Report Data Primary Materials Other System Materials & Deck
Manufacturer Dynamic Uplift Resistance Roof
Assembly
Summary
Test Report Cap
Membrane
Base
Membrane
Plies Insulation
Overlay
Insulation Deck
Overlay
Deck
Type
kPa Psf
Click arrows to sort
Henry Company Canada -3.83 -80 HEN AARS 1-A 2
Steel
Henry Company Canada -4.79 -100 HEN AARS 2-A 2 Steel
IKO Industries Ltd. -4.8 -100 IKO AARS 1-A 2
Steel
IKO Industries Ltd. -2.4 -50 IKO AARS 2-A 2
Steel
IKO Industries Ltd. -4.2 -87 IKO AARS 3-A 2
Steel
IKO Industries Ltd. -4.2 -87 IKO AARS 4-A 2
Steel
IKO Industries Ltd. -4.8 -100 IKO AARS 5-A 2
Steel
IKO Industries Ltd. -2.4 -50 IKO AARS 6-A 2
Steel
IKO Industries Ltd. -4.2 -87 IKO AARS 7-A 2
Steel
IKO Industries Ltd. -3.8 -80 IKO AARS 8-A 2
Steel
IKO Industries Ltd. -2.4 -50 IKO AARS 9-A 2
Steel
IKO Industries Ltd. -3.8 -80 IKO AARS 10-A
2
Steel
IKO Industries Ltd. -3.4 -70 IKO AARS 12-A
2
Steel
IKO Industries Ltd. -3 -62.5 IKO AARS 13-A 2
Steel
IKO Industries Ltd. -4.8 -100 IKO AARS 14-A 2
Steel
IKO Industries Ltd. -4.8 -100 IKO AARS 15-A 2
Steel
IKO Industries Ltd. -3 -62.5 IKO AARS 16-A
2
Steel
IKO Industries Ltd. -4.2 -87 IKO AARS 17-A 2
Steel
IKO Industries Ltd. -3.6 -75 IKO AARS 18-A 2
Steel
IKO Industries Ltd. -5.5 -115 IKO AARS 19-A 2
Plywood
17mm (5/8")
IKO Industries Ltd. -5.5 -115 IKO AARS 20-A 2
Plywood
17mm (5/8")
IKO Industries Ltd. -3.6 -75 IKO AARS 21-A
2
Steel
IKO Industries Ltd. -7.2 -150 IKO AARS 22-A
2
Plywood
17mm (5/8")
IKO Industries Ltd. -5.5 -115 IKO AARS 23-A 2
Steel
IKO Industries Ltd. -5.9 -122.5 IKO AARS 24-A 2
Steel
Siplast, Inc. -2.87 -60 SIP AARS 1-A
2
Steel
Siplast, Inc. -3.35 -70 SIP AARS 2-A
2
Steel
Siplast, Inc. -3.4 -70 SIP AARS 3-A 2
Steel
Siplast, Inc. -2.3 -47 SIP AARS 4-A 2
Steel
Siplast, Inc. -1.9 -40 SIP AARS 5-A 2
Steel
Siplast, Inc. -3.9 -82 SIP AARS 6-A 2 Steel
Siplast, Inc. -5.2 -109 SIP AARS 7-A 2
Steel
Siplast, Inc. -1.4 -30 SIP AARS 8-A 2
Plywood
15mm (19/32")
Soprema Inc. -4.3 -87.3 SOP AARS 1-A 2
Steel
Soprema Inc. -4 -83.3 SOP AARS 2-A 2
Plywood
17mm (5/8")
Soprema Inc. -2.9 -60 SOP AARS 3-A
2
Steel
Soprema Inc. -3 -63 SOP AARS 4-A 2
Steel
Soprema Inc. -2.4 -50 SOP AARS 5-A 2
Steel
Soprema Inc. -3 -63 SOP AARS 6-A 2
Steel
Soprema Inc. -4.3 -90 SOP AARS 7-A 2 Steel
Soprema Inc. -3.4 -72 SOP AARS 8-A 2
Steel
Soprema Inc. -4.8 -100 SOP AARS 8-B 2
Steel
Soprema Inc. -3 -62 SOP AARS 9-A 2
Steel
Soprema Inc. -2.4 -50 SOP AARS 10-A 2
Steel
Soprema Inc. -3.9 -83 SOP AARS 10-B 2
Steel
Soprema Inc. -4.6 -96 SOP AARS 10-C 2
Steel
Soprema Inc. -1.9 -40 SOP AARS 11-A 2
Steel
Soprema Inc. -3.9 -83 SOP AARS 11-B 2
Steel
Soprema Inc. -3.6 -75 SOP AARS 12-A 2
Steel
Soprema Inc. -4.2 -87 SOP AARS 12-B 2
Steel
Soprema Inc. -4.3 -90 SOP AARS 12-C 2
Steel
Soprema Inc. -3.6 -75 SOP AARS 13-A 2 Steel
Soprema Inc. -3.8 -80 SOP AARS 13-B 2 Steel
Soprema Inc. -2.4 -50 SOP AARS 14-A 2
Steel
Soprema Inc. -2.4 -50 SOP AARS 15-A 2
Steel
Soprema Inc. -4.2 -87 SOP AARS 16-A 2
Steel
Soprema Inc. -4.3 -90 SOP AARS 16-B 2
Steel
Soprema Inc. -4 -83 SOP AARS 17-A 2
Plywood
19mm (3/4")
Soprema Inc. -2.4 -50 SOP AARS 18-A
2
Steel
Soprema Inc. -2.4 -50 SOP AARS 18-B
2
Steel
Soprema Inc. -3.4 -72 SOP AARS 19-A 2
Steel
Soprema Inc. -4.8 -100 SOP AARS 19-B 2
Steel
Soprema Inc. -4.3 -90 SOP AARS 20-A 2 Steel
Soprema Inc. -3 -63 SOP AARS 21-A
2 Steel
Soprema Inc. -1.8 -37 SOP-AARS 22-A
2 Steel
Soprema Inc. -1.9 -40 SOP-AARS 22-B
2 Steel
Soprema Inc. -2.4 -50 SOP-AARS 22-C
2 Steel
Soprema Inc. -3.4 -70 SOP-AARS 23-A
2 Steel
Soprema Inc. -2.4 -50 SOP-AARS 24-A
2 Steel
Soprema Inc. -3.6 -75 SOP-AARS 25-A
2
Steel
Soprema Inc. -2.4 -50 SOP-AARS 26-A
2
Steel
Tremco Ltd. -2.5 -53 TRE AARS 1-A 2
Steel
Tremco Ltd. -1.4 -29 TRE AARS 2-A 2
Steel
Tested Assembly Report Data Primary Materials Other System Materials & Deck
Manufacturer Dynamic Uplift Resistance Roof
Assembly
Summary
Test Report Membrane Plies Insulation
Overlay
Insulation Deck
Overlay
Deck
Type
kPa Psf
Elevate (formerly Firestone) -2 -41 FIR AARS 1-A 1
Steel
Tested Assembly Report Data Primary Materials Other System Materials & Deck
Manufacturer Dynamic Uplift Resistance Roof
Assembly
Summary
Test Report Membrane Plies Insulation
Overlay
Insulation Deck
Overlay
Deck
Type
kPa Psf
Elevate (formerly Firestone) -2.4 -50 FIR AARS 2-A 1
Steel
IKO Industries Ltd. -4.19 -87.5 IKO-AARS 25-A 1
Steel
IKO Industries Ltd. -2.39 -50 IKO-AARS 26-A 1
Steel

No Tested Assemblies submitted

Tested Assembly Report Data Primary Materials Other System Materials & Deck
Manufacturer Dynamic Uplift Resistance Roof
Assembly
Summary
Test Report Membrane Plies Insulation
Overlay
Insulation Deck
Overlay
Deck
Type
kPa Psf
IKO Industries Ltd. -4.9 -100 IKO AARS 11-A 4
Steel

Home

© RCABC 2020
No reproduction of these Standards, in whole or in part, is lawful without the expressed permission of the RGC Guarantee Program.