- ::Click below for a printable version of this page (N/A) ...ic (2-ply SBS) or Sealant (Single plies): Drain flange must be embedded in a membrane-compatible mastic and secured to the gutter structure.5 KB (611 words) - 18:17, 12 March 2024
- ...Underlay:</b> RGC accepted self-adhered modified bituminous membrane with a slip sheet overlay of lightweight resin sized or non-asphaltic building pap ...um thickness cold-rolled copper conforming to ASTM B370-98, roll-formed to a maximum panel width of 432 mm (17") with maximum 25 mm (1") tall standing s3 KB (379 words) - 22:50, 21 December 2015
- ...ws with a minimum penetration of 12.5 mm (1/2"). Fasten to wood deck using a minimum of two # 8-14, 4 mm by 31 mm (1 1/4") screws. ...thickness zinc conforming to European standard EN 988-1996, roll-formed to a maximum panel width of 425 mm (17") with maximum 25 mm (1") tall standing s3 KB (421 words) - 22:51, 21 December 2015
- ...' specifications and the '''''RoofStar Guarantee Standards''''' to develop a system acceptable to both the manufacturer and the '''''RoofStar Guarantee5 KB (642 words) - 20:11, 28 June 2022
- ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they [[File:7.4.1.2.3.jpg| link=http://rpm.rcabc.org/images/a/a9/7.4.1.2.3.jpg | class=img-responsive]]4 KB (607 words) - 21:09, 7 September 2021
- ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they ...erlay or eave protection membrane must overlap built-in gutter membrane by a minimum of 200 mm (8") and be installed in shingle fashion (not shown for c3 KB (425 words) - 21:06, 7 September 2021
- ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they ...erlay or eave protection membrane must overlap built-in gutter membrane by a minimum of 200 mm (8") and be installed in shingle fashion (not shown for c3 KB (401 words) - 21:12, 7 September 2021
- ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they ;(2) Sealant: A sealant, mortar or plaster cement should be applied to the tops of the fiel2 KB (370 words) - 21:07, 7 September 2021
- ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they2 KB (311 words) - 21:07, 7 September 2021
- ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they ...or problematic roof.Flashing for a wall termination should lap the tile by a minimum of 100 mm (4"). Material should be the 26-Ga. pre-painted galvanize3 KB (375 words) - 21:08, 7 September 2021
- ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they ;(4) Mortar or mastic: A mortar or mastic bedding should be applied to the tops of the concrete tile2 KB (359 words) - 21:08, 7 September 2021
- ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they ...r the course of tile penetrated by the pipe and under the next course with a 75 mm (3") min. lap.2 KB (298 words) - 21:08, 7 September 2021
- ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they (A) <b>Acceptable Deck</b>3 KB (387 words) - 21:09, 7 September 2021
- ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they Valleys on a slate roof can be done in several ways including swept, laced, mitred and o3 KB (377 words) - 21:10, 7 September 2021
- ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they Hips on a slate roof can be either mitred, saddled or have a metal flashing.2 KB (366 words) - 21:10, 7 September 2021
- ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they Ridges have several traditional styles including saddled or a metal flashing. Ridges are installed after the field slates are installed f3 KB (379 words) - 21:11, 7 September 2021
- ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they :Step flashings are used where a long vertical detail (chimneys, walls, skylights) runs parallel to the slop3 KB (439 words) - 21:11, 7 September 2021
- ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they2 KB (277 words) - 21:11, 7 September 2021
- ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they ;(A) [[Grade-level Waterproofing Standard#WPDECK | '''Acceptable Deck''']]: Con4 KB (484 words) - 21:15, 7 September 2021
- ...]]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ;(A) [[TPO Roof Systems Standard#PART_2|'''Acceptable Deck''']]3 KB (383 words) - 21:38, 27 June 2022