- 16:58, 23 December 2015 (diff | hist) . . (+1,191) . . N TS Details:E4.7.5 (Tile - Curb Flashing) (Created page with "<hr> Curb flashings are applied around skylights, chimneys or other larger penetrations. The basic principle is to deflect the water rushing against the uproof side, safely a...")
- 16:56, 23 December 2015 (diff | hist) . . (+1,061) . . N TS Details:E4.7.4 (Tile - Roof/Wall Transition) (Created page with "<hr> Flashings bridge the gap between field areas and any protrusions such as pipes, vents, and adjoining walls. Because these items impede the flow of water, small deficienci...")
- 16:55, 23 December 2015 (diff | hist) . . (-1,644) . . TS Details:E4.7.2 (Tile - Rake Edge)
- 16:54, 23 December 2015 (diff | hist) . . (+619) . . N TS Details:E4.7.3 (Tile - Pipe Flashing) (Created page with "<hr> Pipe flashings are made of lead which conforms well to the tiles’ surface. They are applied over the course of tile penetrated by the pipe and under the next course...")
- 16:53, 23 December 2015 (diff | hist) . . (+2,356) . . N TS Details:E4.7.2 (Tile - Rake Edge) (Created page with "<hr> Rake tiles cover the exposed edge of field tiles at fascia boards. This helps prevent wind driven rain from entering the system and provides an attractive finish. Rake ti...")
- 16:51, 23 December 2015 (diff | hist) . . (+942) . . N TS Details:E4.7.1 (Tile - Hips & Ridges) (Created page with "<hr> Ridge and hip tiles are applied after the field tiles are terminated against the nailer board. A sealant, mortar or plaster cement should be applied to the tops of the fi...")
- 16:48, 23 December 2015 (diff | hist) . . (-36) . . TS Details:E4.7.13 (Tile/Slate - Guilt-in Gutters)
- 16:47, 23 December 2015 (diff | hist) . . (+1,474) . . N TS Details:E4.7.13 (Tile/Slate - Guilt-in Gutters) (Created page with "<hr> File:8.3.1.jpg ;WORK INCLUDED (1) <b>MEMBRANES:</b> Membranes must be installed to <i>RGC Guarantee Standards</i> and the manufacturer's printed instructions (2) <...")
- 16:46, 23 December 2015 (diff | hist) . . (+92) . . Tile System Details
- 16:44, 23 December 2015 (diff | hist) . . (0) . . TS Details:E4.7.7 (Slate - Standard Application)
- 16:43, 23 December 2015 (diff | hist) . . (+1,475) . . N CS Details:E3.7.4 (Built-in Gutters) (Created page with "<hr> File:8.3.1.jpg ;WORK INCLUDED (1) <b>MEMBRANES:</b> Membranes must be installed to <i>RGC Guarantee Standards</i> and the manufacturer's printed instructions (2) <...")
- 16:42, 23 December 2015 (diff | hist) . . (+66) . . Cedar Shake & Shingle System Details
- 00:24, 23 December 2015 (diff | hist) . . (0) . . File:D1.7.1 (text).jpg (James Klassen uploaded a new version of File:D1.7.1 (text).jpg)
- 00:13, 23 December 2015 (diff | hist) . . (0) . . N File:D1.7.1 (text).jpg
- 23:38, 22 December 2015 (diff | hist) . . (+4) . . TS Details:E4.7.7 (Slate - Standard Application)
- 23:36, 22 December 2015 (diff | hist) . . (+2,497) . . N TS Details:E4.7.7 (Slate - Standard Application) (Created page with "<b>Decking:</b> Slate roofing needs a minimum slope of 1:3 (4" in 12") to achieve required runoff. Slate can be installed over 16 mm (5/8") plywood or 24 mm x 100 mm (1" x 4"...")
- 23:33, 22 December 2015 (diff | hist) . . (+905) . . Tile System Details
- 23:17, 22 December 2015 (diff | hist) . . (+123) . . N Tile System Details (Created page with " <i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Construction Details''")
- 23:16, 22 December 2015 (diff | hist) . . (+121) . . Cedar Shake & Shingle System Details
- 23:11, 22 December 2015 (diff | hist) . . (-270) . . ASM Roof System Details
- 23:10, 22 December 2015 (diff | hist) . . (+3,089) . . N ASM Eave and Rake Edges (Zinc) (Created page with "<hr> The details listed provide metal panel installation information and the fabrication of metal flashing details for non-ferrous metal standing seam roof systems. More speci...")
- 23:10, 22 December 2015 (diff | hist) . . (+2,713) . . N ASM Eave and Rake Edges (Copper) (Created page with "<hr> The details listed provide metal panel installation information and the fabrication of metal flashing details for non-ferrous metal standing seam roof systems. More speci...")
- 23:10, 22 December 2015 (diff | hist) . . (+270) . . ASM Roof System Details
- 23:09, 22 December 2015 (diff | hist) . . (+1,318) . . N ASM Membrane Gutter (Design Elements) (Created page with "<hr> File:8.3.1.jpg ;WORK INCLUDED (1) <b>MEMBRANES:</b> Membranes must be installed to <i>RGC Guarantee Standards</i> and the manufacturer's printed instructions (2) <...")
- 23:07, 22 December 2015 (diff | hist) . . (+67) . . ASM Roof System Details
- 23:05, 22 December 2015 (diff | hist) . . (-108) . . Asphalt Shingle System Details
- 23:05, 22 December 2015 (diff | hist) . . (+108) . . Asphalt Shingle System Details
- 22:28, 22 December 2015 (diff | hist) . . (+1,753) . . N WP Details:F1.7.2 (Wearing Course - Unit Masonry) (Created page with "<hr> File:9.6.2.jpg ;WORK INCLUDED (1)<b>Primary Waterproofing Membrane:</b> Fully adhered to acceptable substrates (concrete slab shown), installed as per <i>RGC Guaran...")
- 22:24, 22 December 2015 (diff | hist) . . (-99) . . Grade-level Waterproofing System Details
- 22:23, 22 December 2015 (diff | hist) . . (+1,685) . . N WP Details:F1.7.1(Wearing Course - Concrete Pavers) (Created page with "<hr> File:9.6.1.jpg ;WORK INCLUDED (1)<b> Primary Waterproofing Membrane:</b> Fully adhered to acceptable substrates (concrete slab shown), installed a per <i>RGC Guaran...")
- 22:23, 22 December 2015 (diff | hist) . . (+99) . . Grade-level Waterproofing System Details
- 22:20, 22 December 2015 (diff | hist) . . (+98) . . N Grade-level Waterproofing System Details (Created page with ":F2.7.1 - Wearing Course (Concrete Pavers)")
- 17:28, 22 December 2015 (diff | hist) . . (+1,246) . . N Template:All Systems - MATERIALS (Created page with "Materials to be covered by the Guarantee Program must be acceptable to RGC. A listing is published in the RCABC Roofing Practices Manual, Section ('''''Reference needed''''')....")
- 17:03, 22 December 2015 (diff | hist) . . (+451) . . N CS Details:E3.7.3 (Hip & Ridge Caps) (Created page with "<hr> File:7.2.4.2.jpg <hr> [[Section:E. Application: Steep Slope Roofs|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Cedar Shakes & Shingles Application'']...")
- 17:02, 22 December 2015 (diff | hist) . . (+451) . . N CS Details:E3.7.2 (Flashings) (Created page with "<hr> File:7.2.4.1.jpg <hr> [[Section:E. Application: Steep Slope Roofs|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Cedar Shakes & Shingles Application'']...")
- 17:01, 22 December 2015 (diff | hist) . . (+453) . . N CS Details:E3.7.1 (Valleys) (Created page with "<hr> File:7.2.3.2.1.jpg <hr> Section:E. Application: Steep Slope Roofs|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Cedar Shakes & Shingles Application'...")
- 16:57, 22 December 2015 (diff | hist) . . (+165) . . N Cedar Shake & Shingle System Details (Created page with ":E3.7.1 Valleys :E3.7.2 Flashings :E3.7.3 Hip & Ridge Caps")
- 23:21, 21 December 2015 (diff | hist) . . (+1,246) . . N All Applications:MATERIALS (Created page with "Materials to be covered by the Guarantee Program must be acceptable to RGC. A listing is published in the RCABC Roofing Practices Manual, Section ('''''Reference needed''''')....") (current)
- 23:11, 21 December 2015 (diff | hist) . . (+1,246) . . N All Applications: MATERIALS (Created page with "Materials to be covered by the Guarantee Program must be acceptable to RGC. A listing is published in the RCABC Roofing Practices Manual, Section ('''''Reference needed''''')....") (current)
- 23:09, 21 December 2015 (diff | hist) . . (+1,246) . . N All Standards: MATERIALS (Created page with "Materials to be covered by the Guarantee Program must be acceptable to RGC. A listing is published in the RCABC Roofing Practices Manual, Section ('''''Reference needed''''')....") (current)
- 22:57, 21 December 2015 (diff | hist) . . (+4) . . Asphalt Shingles - Curb Flashing (Typical)
- 22:57, 21 December 2015 (diff | hist) . . (+5) . . AS Details:E2.7.11 (Counter-flashing - Diverter Flashing) (current)
- 22:56, 21 December 2015 (diff | hist) . . (-80) . . Asphalt Shingle System Details
- 22:56, 21 December 2015 (diff | hist) . . (+80) . . Asphalt Shingle System Details
- 22:55, 21 December 2015 (diff | hist) . . (+5) . . Asphalt Shingles - Flashing a Masonry Chimney
- 22:55, 21 December 2015 (diff | hist) . . (+5) . . Asphalt Shingles - Intersection with Waterproofing Roof (Lower)
- 22:54, 21 December 2015 (diff | hist) . . (+5) . . Asphalt Shingles - Intersection with Waterproofing Roof (Upper)
- 22:54, 21 December 2015 (diff | hist) . . (+5) . . Asphalt Shingles - Woven Valley
- 22:54, 21 December 2015 (diff | hist) . . (-1) . . Asphalt Shingles - Closed (Cut) Valley
- 22:53, 21 December 2015 (diff | hist) . . (+5) . . Asphalt Shingles - Closed (Cut) Valley