Search results

Jump to: navigation, search

Search results

  • ...bership list and contact information at [http://www.rcabc.org/members/find-a-member/ www.rcabc.org] ...d data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For
    5 KB (684 words) - 14:23, 27 October 2023
  • * {{hilite | A First Observation that includes an evaluation of the supporting deck surfac * {{hilite | Regular observations, on a daily basis when possible or as otherwise mandated by the RoofStar Fee Calc
    2 KB (284 words) - 18:25, 19 August 2021
  • ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan ...m, as they relate to the specific project. Many factors affect the life of a roof system and should be of concern to the owner and design authority.
    3 KB (386 words) - 15:33, 9 September 2021
  • ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan
    2 KB (308 words) - 15:59, 9 September 2021
  • ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan ...system, HVAC units and, possibly, landscaping. Most decks must also act as a diaphragm, transmitting wind or seismic lateral forces to the buildings str
    20 KB (2,969 words) - 16:06, 9 September 2021
  • ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan ...placed over steel decks to provide a level surface for the membrane, or as a thermal barrier between the roof deck and combustible insulation.
    1 KB (198 words) - 15:33, 9 September 2021
  • ...ly varied by the ''Guarantor'' under the terms of the Guarantee issued for a ''project''. <li>The requirements for a '''''RoofStar 15-year Guarantee''''' shall be as described in Part 1 of the
    11 KB (1,608 words) - 22:03, 3 May 2021
  • <big><big>Division A - Scope, Use of Standards, and Guarantee </big></big> .... In 2016, the wiki-based ''RPM'' was restructured to form five Divisions, A through E.
    15 KB (2,132 words) - 19:02, 18 August 2023
  • ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan ...(or shelter) that is not governed by the exterior environment. The roof is a fundamental component of this design and must perform several functions. As
    23 KB (3,279 words) - 15:42, 9 September 2021
  • '''NOTE''': Presently, there are no butyl membranes accepted for use in a '''''RoofStar Guaranteed''''' Waterproofing assembly.
    406 bytes (46 words) - 14:10, 27 July 2021
  • ...lished Technical Data sheets, but this information not intended for use as a comparison of material performance or quality. It is the sole responsiblity ...s, to provide a minimum double coverage. Capping must be installed in such a manner that nails are not exposed. Continuous proprietary ridge venting s
    3 KB (399 words) - 14:12, 27 July 2021
  • ...ture monitoring sensor grids are pavers on pedestals and gravel ballast to a maximum 100mm (4") thick . Moisture monitoring sensor grids<b> shall </b>be :Flood Testing is <b>not a recommended practice</b> but is at the discretion of the design authority o
    2 KB (249 words) - 22:45, 9 November 2016
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they
    2 KB (225 words) - 21:24, 7 September 2021
  • ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan * the insulation may be incompatible with the membrane, resulting in a loss of physical properties
    4 KB (532 words) - 15:44, 9 September 2021
  • [[File:10.3.7.1.jpg| link=http://rpm.rcabc.org/images/a/a0/10.3.7.1.jpg | class=img-responsive]] ...ndard#PART_12|'''Protected Membrane Roof Assembly''']]: Flashing to extend a minimum 200 mm (8") above finished roof surface (pavers, ballast, or walkwa
    3 KB (360 words) - 18:16, 27 October 2023
  • ;(A) [[SBS Roof Systems Standard#PART_2|'''Acceptable Deck''']]:
    2 KB (262 words) - 18:33, 27 June 2022
  • ;(A) [[SBS Roof Systems Standard#PART_2|'''Acceptable Supporting Deck Structure
    2 KB (284 words) - 18:34, 27 June 2022
  • ;(A) [[TPO Roof Systems Standard#PART_2|'''Acceptable Deck''']]
    3 KB (429 words) - 21:34, 27 June 2022
  • ...]]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ;(A) [[EPDM Roof Systems Standard#PART_2|'''Acceptable Deck''']]
    3 KB (367 words) - 21:52, 27 June 2022
  • ...]]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ;(A) [[RoofStar Guarantee Standards for EPDM Roof Assemblies#EPDMDECKS|'''Accep
    3 KB (351 words) - 16:48, 23 October 2017

View (previous 20 | next 20) (20 | 50 | 100 | 250 | 500)