Manufacturer | Product Name | Number of Tested Systems (per report) |
kPa (Low) | kPa (High) | Psf (Low) | Psf (High) | Deck Type | Downloadable Test Report | Test Facility | Test Facility Report No. |
---|---|---|---|---|---|---|---|---|---|---|
Carlisle Syntec Systems Canada | Sure-Weld 45 mil TPO Membrane | 1 Tested System 1 Tested System |
---- ---- |
-3.40 -3.40 |
---- ---- |
-70.00 -71.00 |
Steel Steel |
MARS Test Report 3 MARS Test Report 4 |
exp. Service Inc. | PUB-DRU236018 PUB-DRU168402 |
Firestone Building Products | Ultraply 1.2 mm TPO Membrane | 1 Tested System 2 Tested Systems 1 Tested System 1 Tested System |
---- -3.80 ---- ---- |
-3.20 -4.20 -3.80 -3.00 |
---- -80.00 ---- ---- |
-67.00 -87.00 -80.00 -63.00 |
Steel Steel Steel Steel |
MARS Test Report 3 MARS Test Report 4 MARS Test Report 5 MARS Test Report 6 |
exp. Service Inc. | PUB-DRU303384 PUB-DRU168455 PUB-DRU303385 PUB-DRU168431 |
Firestone Building Products | UltraPly 1.6 mm TPO Membrane | 1 Tested System 2 Tested Systems 1 Tested System 1 Tested System |
---- -3.80 ---- ---- |
-3.20 -4.20 -3.80 -3.00 |
---- -80.00 ---- ---- |
-67.00 -87.00 -80.00 -63.00 |
Steel Steel Steel Steel |
MARS Test Report 3 MARS Test Report 4 MARS Test Report 5 MARS Test Report 6 |
exp. Service Inc. | PUB-DRU303384 PUB-DRU168455 PUB-DRU303385 PUB-DRU168431 |