1 WORK INCLUDED
- (1) Underlayment
- The type of underlay required is determined by roof slope.
- (2) Slip Sheet
- Recommended over asphaltic underlays and / or as required by metal roof panel manufacturer.
- (3) Metal Panel Clip
- Installed to metal roof panel manufacturer's printed instructions.
- (4) Architectural Metal Roof Panel
- (5) Metal Curb Flashing
- (6) Cricket
- Required for curbs more than 900 mm (36") wide
- (7) Acceptable Caulking
- Two rows accepted caulking between overlapping sheets, with preformed closures on trapezoidal ribbed roof panels.
- (8) Metal Counter Flashing
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
- (B) Wood Curb
- 200 mm (8") minimum height
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.