Table Drafts 4

Jump to: navigation, search

Table Drafts 4

Revision as of 19:20, 11 December 2020 by James Klassen (talk | contribs) (Created page with "===Part 9: Single-ply Table (5-year Guarantee)=== {| class="wikitable mw-datatable" style="margin-left: 10pt; margin-right: auto;border-color:#E7E9E9;vertical-alig...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

1 Part 9: Single-ply Table (5-year Guarantee)

Table 9.1 Single-ply Membranes: RoofStar 5 and 10-Year Guarantee
(Applies to Field and Flashing membranes. All thicknesses shown are in mm.)
Exposed Roof Systems Protected Roof Systems Grade-level
Water-
proofing
Conventionally Insulated / Uninsulated Systems Built-in
Gutters
Ballasted PMR
Systems
Mechanically
Fastened*
Self-adhered Adhered Adhesive-
applied
or
Self-adhered
Loose-laid Self-adhered,
Adhesive-
applied
or
Hot-mopped
Self-adhered,
Adhesive-
applied
or
Hot-mopped
Adhesive-
applied
or
Hot-mopped
(Smooth)
Adhesive-
applied
or
Hot-mopped
(Fleece-backed)
Type, Reinforcement, Grade mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils)
EPDM (reinforced) 1.524 (60) 1.524 (60) 1.143 (45) 1.524 (60) 1.143 (45) 1.143 (45)
EPDM (unreinforced) 1.524 (60) 1.143 (45) 2.794 (110) 1.524 (60) 1.143 (45) 1.143 (45)
TPO 1.143 (45) 1.524 (60) 1.143 (45) 2.794 (110) 1.524 (60) 1.143 (45) 1.143 (45)
PVC 1.270 (50) 1.270 (50) 2.667 (105) 1.524 (60) 1.270 (50) 1.270 (50) 1.524 (60)
*Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.

2 Part 9: Single-ply Table (10-year Guarantee)

Table 9.1 Single-ply Membranes: RoofStar 5 and 10-Year Guarantee
(Applies to Field and Flashing membranes. All thicknesses shown are in mm.)
Exposed Roof Systems Protected Roof Systems Grade-level
Water-
proofing
Conventionally Insulated / Uninsulated Systems Built-in
Gutters
Ballasted PMR
Systems
Mechanically
Fastened*
Self-adhered Adhered Adhesive-
applied
or
Self-adhered
Loose-laid Self-adhered,
Adhesive-
applied
or
Hot-mopped
Self-adhered,
Adhesive-
applied
or
Hot-mopped
Adhesive-
applied
or
Hot-mopped
(Smooth)
Adhesive-
applied
or
Hot-mopped
(Fleece-backed)
Type, Reinforcement, Grade mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils)
EPDM (reinforced) 1.524 (60) 1.524 (60) 1.143 (45) 1.524 (60) 1.143 (45) 1.143 (45)
EPDM (unreinforced) 1.524 (60) 1.143 (45) 2.794 (110) 1.524 (60) 1.143 (45) 1.143 (45)
TPO 1.143 (45) 1.524 (60) 1.143 (45) 2.794 (110) 1.524 (60) 1.143 (45) 1.143 (45)
PVC 1.270 (50) 1.270 (50) 2.667 (105) 1.524 (60) 1.270 (50) 1.270 (50) 1.524 (60)
*Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.

3 Part 9: Single-ply Table (15-year Guarantee)

Table 9.2 Single-ply Membranes: RoofStar 15-Year Guarantee
(Applies to Field and Flashing membranes. All thicknesses shown are in mm.)
Exposed Roof Systems Protected Roof Systems Grade-level
Water-
proofing
Conventionally Insulated / Uninsulated Systems Built-in
Gutters
Ballasted PMR
Systems
Mechanically
Fastened*
Self-adhered Adhered Adhesive-
applied
or
Self-adhered
Loose-laid Self-adhered,
Adhesive-
applied
or
Hot-mopped
Self-adhered,
Adhesive-
applied
or
Hot-mopped
Adhesive-
applied
or
Hot-mopped
(Smooth)
Adhesive-
applied
or
Hot-mopped
(Fleece-backed)
Type, Reinforcement, Grade mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils)
EPDM (reinforced) 1.524 (60) 1.524 (60) 1.524 (60) 2.032 (80) 1.524 (60)
EPDM (unreinforced) 1.524 (60) 1.524 (60) 2.790 (110) 2.032 (80) 1.524 (60)
TPO 1.524 (60) 1.524 (60) 1.524 (60) 2.790 (110) 2.286 (90) 1.524 (60)
PVC 1.524 (60) 1.524 (60) 2.667 (105) 2.286 (90) 1.524 (60)
*Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.