Table Drafts 4

Jump to: navigation, search

Table Drafts 4

Revision as of 19:41, 14 December 2020 by James Klassen (talk | contribs) (Part 9: EPDM Table (Combined 5, 10, 15))

1 Part 9: EPDM Table (Combined 5, 10, 15)

Table 9.1 EPDM Membranes: RoofStar 5, 10 & 15-year Guarantees
(Applies to Field and Flashing membranes. All thicknesses shown are in mm and mils)
Exposed Roof Systems Protected Roof Systems Grade-level
Water-
proofing
Conventionally Insulated / Uninsulated Systems Built-in
Gutters
Ballasted PMR
Systems
Mechanically
Fastened
or
Induction
Welded*
Self-adhered Adhered
or
Hot-mopped
Adhered
or
Self-adhered
Loose-laid Self-adhered,
Adhered
or
Hot-mopped
Self-adhered,
Adhered
or
Hot-mopped
Type, Reinforcement, Grade Guarantee Term mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils)
EPDM (reinforced)
5 1.524 (60) 1.524 (60) 1.143 (45) 1.524 (60) 1.143 (45) 1.143 (45) X
10 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) X
15 2.286 (90) X N/A 1.524 (60) X N/A X
EPDM (unreinforced)
5 X 1.524 (60) 1.143 (45) 1.524 (60) 1.143 (45) 1.143 (45) X
10 X 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) X
15 X X 2.286 (90) 2.286 (90) X 2.286 (90) X
*Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.

2 Part 9: TPO Table (Combined 5, 10, 15)

Table 9.1 TPO Membranes: RoofStar 5, 10 & 15-year Guarantees
(Applies to Field and Flashing membranes. All thicknesses shown are in mm.)
Exposed Roof Systems Protected Roof Systems Grade-level
Water-
proofing
Conventionally Insulated / Uninsulated Systems Built-in
Gutters
Ballasted PMR
Systems
Mechanically
Fastened
or
Induction
Welded*
Self-adhered Adhered
or
Hot-mopped
Adhered
or
Self-adhered
Loose-laid Self-adhered,
Adhered
or
Hot-mopped
Self-adhered,
Adhered
or
Hot-mopped
Type, Reinforcement, Grade Guarantee Term mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils)
TPO
5 1.143 (45) 1.524 (60) 1.143 (45) 1.524 (60) 1.143 (45) 1.143 (45)
10 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60)
15 2.032 (80) 2.032 (80) 2.032 (80) 2.032 (80)
*Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.

3 Part 9: PVC Table (Combined 5, 10, 15)

Table 9.1 PVC Membranes: RoofStar 5, 10 & 15-year Guarantees
(Applies to Field and Flashing membranes. All thicknesses shown are in mm.)
Exposed Roof Systems Protected Roof Systems Grade-level
Water-
proofing
Conventionally Insulated / Uninsulated Systems Built-in
Gutters
Ballasted PMR
Systems
Mechanically
Fastened
or
Induction
Welded*
Self-adhered Adhered
or
Hot-mopped
Adhered
or
Self-adhered
Loose-laid Self-adhered,
Adhered
or
Hot-mopped
Self-adhered,
Adhered
or
Hot-mopped
Type, Reinforcement, Grade Guarantee Term mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils)
PVC
5 1.270 (50) 1.270 (50) 1.524 (60) 1.270 (50) 1.270 (50) 1.524 (60)
10 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60)
15 2.032 (80) 2.032 (80) 2.032 (80) 2.032 (80)
*Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.

4 Part 9: 2-ply Model (Combined 5, 10, 15)

Table 9.1 SBS-modified Bituminous Membranes: RoofStar 5 and 10-Year Guarantee
Applies to Field and Flashing membranes. All thicknesses shown are in mm
Exposed Roof Systems Protected Roof Systems Grade-level
Water-
proofing
Conventionally Insulated / Uninsulated Systems Built-in
Gutters
PMR
Systems
Mechanic-
ally
fastened
Heat-
welded
Adhered Heat-
welded,
Adhesive-
applied,
Self-
adhered

Heat-
welded,
Adhesive-
applied
Puncture Resistance Heat-
welded,
Adhesive-
applied,
Self-
adhered
Puncture Resistance
Self-
adhered
Hot-
mopped
Adhesive-
applied
Type, Reinforcement, Grade Guarantee Term mm mm mm mm mm mm mm (N) mm (N)
Minimum Combined 2-ply Thickness
5/10 xxxx xxxx xxxx xxxx xxxx
15 xxxx xxxx xxxx xxxx xxxx
Base (Fibreglass) - Gr. 3
5/10 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
15 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
Base (Composite fibreglass) - Gr. 3
5/10 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
15 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
Base (Polyester) - Gr. 3
5/10 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
15 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
Base (Composite) - Gr. 3
5/10 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
15 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
Factory Laminated Base (panel)
5/10 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
15 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
Film Cap (Fibreglass) - Gr. 2
5/10 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
15 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
Film Cap (Polyester) - Gr. 2
5/10 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
15 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
Film Cap (Composite) - Gr. 2
5/10 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
15 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
Granule Cap (Fibreglass) - Gr. 1
5/10 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
15 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
Granule Cap (Polyester) - Gr. 1
5/10 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
15 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
Granule Cap (Composite) - Gr. 1
5/10 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
15 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx


Table 9.1 SBS-modified Bituminous Membranes: RoofStar 5 and 10-Year Guarantee
Applies to Field and Flashing membranes. All thicknesses shown are in mm
Exposed Roof Systems Protected Roof Systems Grade-level
Water-
proofing
Conventionally Insulated / Uninsulated Systems Built-in
Gutters
PMR
Systems
Mechanic-
ally
fastened
Heat-
welded
Adhered Heat-
welded,
Adhesive-
applied,
Self-
adhered

Heat-
welded,
Adhesive-
applied
Puncture Resistance Heat-
welded,
Adhesive-
applied,
Self-
adhered
Puncture Resistance
Self-
adhered
Hot-
mopped
Adhesive-
applied
Type, Reinforcement, Grade mm mm mm mm mm mm mm (N) mm (N)
Minimum Combined 2-ply Thickness 6.00 6.00 N/A 6.00 N/A
Base (Fibreglass) - Gr. 3 2.30 2.30 2.30 2.20 2.20
Base (Composite fibreglass) - Gr. 3 2.30 2.30 2.30 2.20 2.20 2.50 2.20 2.20
Base (Polyester) - Gr. 3 2.50 2.50 2.50 2.20 2.20 2.50 2.20 2.20
Base (Composite) - Gr. 3 2.30 2.30 2.30 2.20 2.20 2.50 2.20 2.20
Factory Laminated Base (panel) 2.20 2.20 N/A N/A
Film Cap (Fibreglass) - Gr. 2 4.00 3.30 3.30 3.30
Film Cap (Polyester) - Gr. 2 4.00 3.50 3.50 3.50 3.00 3.00 400 3.00 400
Film Cap (Composite) - Gr. 2 4.00 3.30 3.30 3.30 3.00 3.00 400 3.00 400
Granule Cap (Fibreglass) - Gr. 1 4.00 3.30 3.30 3.30
Granule Cap (Polyester) - Gr. 1 4.00 3.50 3.50 3.50 3.50 3.00 400 3.00 400
Granule Cap (Composite) - Gr. 1 3.30 4.00 3.30 3.30 3.50 3.00 400 3.00 400



Table 9.1 SBS-modified Bituminous Membranes: RoofStar 5 and 10-Year Guarantee
Applies to Field and Flashing membranes. All thicknesses shown are in mm
Exposed Roof Systems Protected Roof Systems Grade-level
Water-
proofing
Conventionally Insulated / Uninsulated Systems Built-in
Gutters
PMR
Systems
Mechanic-
ally
fastened
Heat-
welded
Adhered Heat-
welded,
Adhesive-
applied,
Self-
adhered

Heat-
welded,
Adhesive-
applied
Puncture Resistance Heat-
welded,
Adhesive-
applied,
Self-
adhered
Puncture Resistance
Self-
adhered
Hot-
mopped
Adhesive-
applied
Type, Reinforcement, Grade mm mm mm mm mm mm mm (N) mm (N)
Minimum Combined 2-ply Thickness 7.00 7.00 N/A 7.00 N/A
Base (fibreglass) - Gr. 3 2.50 2.50 2.50 2.50
Base (Composite fibreglass) - Gr. 3 2.50 2.50 2.50 2.50 2.90 2.50 2.50
Base (polyester) - Gr. 3 2.50 2.50 2.50 2.50 2.90 2.50 2.50
Base (composite) - Gr. 3 2.50 2.50 2.50 2.50 2.90 2.50 2.50
Factory Laminated Base (panel) 2.20 2.20 N/A N/A
Film Cap (fibreglass) - Gr. 2
Film Cap (polyester) - Gr. 2 4.00 4.00 4.00 4.00 4.00 3.00 400 3.50 400
Film Cap (composite) - Gr. 2 4.00 4.00 4.00 4.00 4.00 3.00 400 3.50 400
Granular Cap (fibreglass) - Gr. 1 4.00 4.00 4.00 4.00
Granular Cap (polyester) - Gr. 1 4.00 4.00 4.00 4.00 4.00 3.00 400 3.50 400
Granular Cap (composite) - Gr. 1 4.00 4.00 4.00 4.00 4.00 3.00 400 3.50 400