Table Drafts 4

Jump to: navigation, search

Table Drafts 4

Revision as of 20:02, 14 December 2020 by James Klassen (talk | contribs) (Part 9: 2-ply Model (Combined 5, 10, 15))

1 Part 9: EPDM Table (Combined 5, 10, 15)

Table 9.1 EPDM Membranes: RoofStar 5, 10 & 15-year Guarantees
(Applies to Field and Flashing membranes. All thicknesses shown are in mm and mils)
Exposed Roof Systems Protected Roof Systems Grade-level
Water-
proofing
Conventionally Insulated / Uninsulated Systems Built-in
Gutters
Ballasted PMR
Systems
Mechanically
Fastened
or
Induction
Welded*
Self-adhered Adhered
or
Hot-mopped
Adhered
or
Self-adhered
Loose-laid Self-adhered,
Adhered
or
Hot-mopped
Self-adhered,
Adhered
or
Hot-mopped
Type, Reinforcement, Grade Guarantee Term mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils)
EPDM (reinforced)
5 1.524 (60) 1.524 (60) 1.143 (45) 1.524 (60) 1.143 (45) 1.143 (45) X
10 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) X
15 2.286 (90) X N/A 1.524 (60) X N/A X
EPDM (unreinforced)
5 X 1.524 (60) 1.143 (45) 1.524 (60) 1.143 (45) 1.143 (45) X
10 X 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) X
15 X X 2.286 (90) 2.286 (90) X 2.286 (90) X
*Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.

2 Part 9: TPO Table (Combined 5, 10, 15)

Table 9.1 TPO Membranes: RoofStar 5, 10 & 15-year Guarantees
(Applies to Field and Flashing membranes. All thicknesses shown are in mm.)
Exposed Roof Systems Protected Roof Systems Grade-level
Water-
proofing
Conventionally Insulated / Uninsulated Systems Built-in
Gutters
Ballasted PMR
Systems
Mechanically
Fastened
or
Induction
Welded*
Self-adhered Adhered
or
Hot-mopped
Adhered
or
Self-adhered
Loose-laid Self-adhered,
Adhered
or
Hot-mopped
Self-adhered,
Adhered
or
Hot-mopped
Type, Reinforcement, Grade Guarantee Term mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils)
TPO
5 1.143 (45) 1.524 (60) 1.143 (45) 1.524 (60) 1.143 (45) 1.143 (45) X
10 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) X
15 2.032 (80) 2.032 (80) 2.032 (80) 2.032 (80) X 2.032 (80) X
*Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.

3 Part 9: PVC Table (Combined 5, 10, 15)

Table 9.1 PVC Membranes: RoofStar 5, 10 & 15-year Guarantees
(Applies to Field and Flashing membranes. All thicknesses shown are in mm.)
Exposed Roof Systems Protected Roof Systems Grade-level
Water-
proofing
Conventionally Insulated / Uninsulated Systems Built-in
Gutters
Ballasted PMR
Systems
Mechanically
Fastened
or
Induction
Welded*
Self-adhered Adhered
or
Hot-mopped
Adhered
or
Self-adhered
Loose-laid Self-adhered,
Adhered
or
Hot-mopped
Self-adhered,
Adhered
or
Hot-mopped
Type, Reinforcement, Grade Guarantee Term mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils)
PVC
5 1.270 (50) X 1.270 (50) 1.524 (60) 1.270 (50) 1.270 (50) 1.524 (60)
10 1.524 (60) X 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60)
15 2.032 (80) X 2.032 (80) 2.032 (80) X 2.032 (80) X
*Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.

4 Part 9: 2-ply Model (Combined 5, 10, 15)

Table 9.1 SBS-modified Bituminous Membranes: RoofStar 5 and 10-Year Guarantee
Applies to Field and Flashing membranes. All thicknesses shown are in mm
Exposed Roof Systems Protected Roof Systems Grade-level
Water-
proofing
Conventionally Insulated / Uninsulated Systems Built-in
Gutters
PMR
Systems
Mechanic-
ally
fastened
Heat-
welded
Adhered Heat-
welded,
Adhesive-
applied,
Self-
adhered

Heat-
welded,
Adhesive-
applied
Puncture Resistance Heat-
welded,
Adhesive-
applied,
Self-
adhered
Puncture Resistance
Self-
adhered
Hot-
mopped
Adhesive-
applied
Type, Reinforcement, Grade Guarantee Term mm mm mm mm mm mm mm (N) mm (N)
Minimum Combined 2-ply Thickness
5/10 6.00 6.00 N/A 6.00 N/A
15 7.00 7.00 N/A 7.00 N/A
Base (Fibreglass) - Gr. 3
5/10 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
15 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
Base (Composite fibreglass) - Gr. 3
5/10 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
15 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
Base (Polyester) - Gr. 3
5/10 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
15 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
Base (Composite) - Gr. 3
5/10 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
15 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
Factory Laminated Base (panel)
5/10 2.20 X 2.20 N/A X N/A
15 2.20 X 2.20 N/A X N/A
Film Cap (Fibreglass) - Gr. 2
5/10 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
15 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
Film Cap (Polyester) - Gr. 2
5/10 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
15 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
Film Cap (Composite) - Gr. 2
5/10 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
15 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
Granule Cap (Fibreglass) - Gr. 1
5/10 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
15 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
Granule Cap (Polyester) - Gr. 1
5/10 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
15 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
Granule Cap (Composite) - Gr. 1
5/10 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
15 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx

5 Part 9: 2-ply Models (current)

Table 9.1 SBS-modified Bituminous Membranes: RoofStar 5 and 10-Year Guarantee
Applies to Field and Flashing membranes. All thicknesses shown are in mm
Exposed Roof Systems Protected Roof Systems Grade-level
Water-
proofing
Conventionally Insulated / Uninsulated Systems Built-in
Gutters
PMR
Systems
Mechanic-
ally
fastened
Heat-
welded
Adhered Heat-
welded,
Adhesive-
applied,
Self-
adhered

Heat-
welded,
Adhesive-
applied
Puncture Resistance Heat-
welded,
Adhesive-
applied,
Self-
adhered
Puncture Resistance
Self-
adhered
Hot-
mopped
Adhesive-
applied
Type, Reinforcement, Grade mm mm mm mm mm mm mm (N) mm (N)
Minimum Combined 2-ply Thickness 6.00 6.00 N/A 6.00 N/A
Base (Fibreglass) - Gr. 3 2.30 2.30 2.30 2.20 2.20
Base (Composite fibreglass) - Gr. 3 2.30 2.30 2.30 2.20 2.20 2.50 2.20 2.20
Base (Polyester) - Gr. 3 2.50 2.50 2.50 2.20 2.20 2.50 2.20 2.20
Base (Composite) - Gr. 3 2.30 2.30 2.30 2.20 2.20 2.50 2.20 2.20
Factory Laminated Base (panel) 2.20 2.20 N/A N/A
Film Cap (Fibreglass) - Gr. 2 4.00 3.30 3.30 3.30
Film Cap (Polyester) - Gr. 2 4.00 3.50 3.50 3.50 3.00 3.00 400 3.00 400
Film Cap (Composite) - Gr. 2 4.00 3.30 3.30 3.30 3.00 3.00 400 3.00 400
Granule Cap (Fibreglass) - Gr. 1 4.00 3.30 3.30 3.30
Granule Cap (Polyester) - Gr. 1 4.00 3.50 3.50 3.50 3.50 3.00 400 3.00 400
Granule Cap (Composite) - Gr. 1 3.30 4.00 3.30 3.30 3.50 3.00 400 3.00 400



Table 9.1 SBS-modified Bituminous Membranes: RoofStar 5 and 10-Year Guarantee
Applies to Field and Flashing membranes. All thicknesses shown are in mm
Exposed Roof Systems Protected Roof Systems Grade-level
Water-
proofing
Conventionally Insulated / Uninsulated Systems Built-in
Gutters
PMR
Systems
Mechanic-
ally
fastened
Heat-
welded
Adhered Heat-
welded,
Adhesive-
applied,
Self-
adhered

Heat-
welded,
Adhesive-
applied
Puncture Resistance Heat-
welded,
Adhesive-
applied,
Self-
adhered
Puncture Resistance
Self-
adhered
Hot-
mopped
Adhesive-
applied
Type, Reinforcement, Grade mm mm mm mm mm mm mm (N) mm (N)
Minimum Combined 2-ply Thickness 7.00 7.00 N/A 7.00 N/A
Base (fibreglass) - Gr. 3 2.50 2.50 2.50 2.50
Base (Composite fibreglass) - Gr. 3 2.50 2.50 2.50 2.50 2.90 2.50 2.50
Base (polyester) - Gr. 3 2.50 2.50 2.50 2.50 2.90 2.50 2.50
Base (composite) - Gr. 3 2.50 2.50 2.50 2.50 2.90 2.50 2.50
Factory Laminated Base (panel) 2.20 2.20 N/A N/A
Film Cap (fibreglass) - Gr. 2
Film Cap (polyester) - Gr. 2 4.00 4.00 4.00 4.00 4.00 3.00 400 3.50 400
Film Cap (composite) - Gr. 2 4.00 4.00 4.00 4.00 4.00 3.00 400 3.50 400
Granular Cap (fibreglass) - Gr. 1 4.00 4.00 4.00 4.00
Granular Cap (polyester) - Gr. 1 4.00 4.00 4.00 4.00 4.00 3.00 400 3.50 400
Granular Cap (composite) - Gr. 1 4.00 4.00 4.00 4.00 4.00 3.00 400 3.50 400