ASM Eave Protection and Underlayment (Low Slopes)
ASM Eave Protection and Underlayment (Low Slopes)
Revision as of 14:55, 28 June 2022 by James Klassen (talk | contribs)
Division D - Construction Details
ASM | Eave Protection and Underlayment (Low Slopes) ( Article 8.3.2.1. and Article 8.3.2.4.)
Notice to Reader | |
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).
The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text. |
ASM Details
1 WORK INCLUDED
- (1) Metal flashing underlayment/separation membrane
- Required for metal flashings installed on wood substrates.
- (2) Metal edge flashing
- Installed to manufacturer's printed instructions.
- (3) Ice and water protection
- One ply of accepted self-adhered modified bituminous membrane.
- This application is required only for slopes less than 1:3 (4" in 12"). For slopes 1:3 or greater, see Eave Protection and Underlayment.
- Separation layer not shown for clarity
2 RELATED WORK BY OTHERS
- (A) Acceptable deck
NOTE: See the Standard for additional requirements.
Back to ASM Roof System Details