ASM Eave and Rake Edges (Snap-Lock Seams)
ASM Eave and Rake Edges (Snap-Lock Seams)
Revision as of 18:04, 28 June 2022 by James Klassen (talk | contribs)
Division D - Construction Details
ASM | Eave and Rake Edges (Snap-Lock Seams) ( Article 10.3.2.3. and Article 10.3.4.2.)
Notice to Reader | |
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).
The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text. |
ASM Details
1 WORK INCLUDED
- (1) Eave Protection
- Accepted self-adhered modified bituminous membrane.
- (2) Separation Layer
- Recommended over asphaltic underlays and / or as required by metal panel manufacturer.
- (3) Metal Panel Clip
- Installed to metal roof panel manufacturer's printed instructions.
- (4) Architectural Metal Roof Panel
- (5) Continuous Metal Cleat
- (6) Metal Fascia Flashing
- (7) Edge Metal Flashing (Continuous)
- (8) Pre-formed Closures
- (9) Exposed Fasteners
- High-domed gasketed cladding type screws compatible with metal roof panel.
- (10) Rake Edge Metal Flashing
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
- (B) Fascia Board
NOTE: See the Standard for additional requirements.
Back to ASM Roof System Details
© RCABC 2024
RoofStarTM is a registered Trademark of the RCABC.