CSA Tested Assemblies Draft 1

Jump to: navigation, search

CSA Tested Assemblies Draft 1

Revision as of 14:42, 10 June 2020 by James Klassen (talk | contribs) (MARS)

Contents

1 MARS

About the Tables

The tables on the adjacent tabs display data from, and links to, Tested Assembly Reports listed by the membrane type shown on the tab. Dynamic Wind Uplift (DUR) values are shown in sortable columns. Only the DUR and Manufacturer columns are sortable; to sort a column, click the column heading.

Deck types tested with the Assembly are shown in the far right column.

Structure and Organization of Tables

Before you use these tables, know the wind load requirements for the roof under design or construction by reading Part 3 SECURING the ROOF ASSEMBLY of the membrane standard applicable to the roof you are designing or constructing. You can calculate the Specified Wind Loads for the three principal roof zones by either using the formulae in the British Columbia Building Code, 4.1.7 Wind Loads, or by using the National Research Council's online tool, Wind-RCI online wind calculator.

The tables on this page display a collection of test data and downloadable reports offered for the purpose of designing and constructing a roof capable of resisting negative wind pressures, commonly referred to as "wind uplift". The data and reports are offered without endorsement by the RCABC; they are provided as a courtesy by the RoofStar Guarantee Program to assist the Design Authority with the task of designing a roof that satisfies Code requirements, that meets the designer's specific and numerous design preferences, and that will qualify for a RoofStar Guarantee.

The British Columbia Building Code (or the Code having jurisdiction) requires a roof to be capable of resisting Specified Wind Loads (see the British Columbia Building Code, Part 4 (4.1.7 Wind Loads) and Part 5 (5.2.2.2 Determination of Wind Load), inclusive of the notes in the appendices). The reader will note that there are optional pathways by which a roof design can comply with the Code. One pathway is the use of a "Tested Assembly" - a roof assembly tested in controlled laboratory conditions to resist simulated wind pressures and gusts. The test must be conducted in strict conformity to CSA-A123.21 Standard test method for the dynamic wind uplift resistance of membrane roofing systems (CSA-A123.21). The results of the test are published in a report signed off by the accredited testing agency. Each report details the materials and securement methods of the assembly. Every detail in a Tested Assembly report is critical for the performance of a roof designed on the basis of the tested assembly.

CSA-A123.21 requires that the published test limits for a roof system be adjusted with a safety factor of 1.5; this factor reduces the actual test results in order to account for variabilities that a laboratory cannot test for, such as strong wind gusts. The Dynamic Uplift Resistance (DUR) values in the following tables conform to this requirement, and can be validated by reviewing the downloadable test reports.

It is imperative that the user of these reports become familiar with the structure and content typical in a Tested Assembly report. While you will see that each accredited testing agency publishes test results in their own preferred format, there is general consistency among the report styles in the type of data each report provides:

  • the DUR
  • a list of tested and alternate materials
  • how each material was secured, and
  • the size of fasteners or the types of adhesive used.


All of these variables, and more, affect the performance of the roof assembly. Care must therefore be taken to collect and analyze all this information in relation to the limitations of the building and the roof, and all these details (for example, the specific name of the adhesive and how it was applied) must be included in the design specifications that will ultimately guide the construction of the roof.

Drop-down lists (see the example below) provide a quick summary of the tested and optional materials available for the

  • roof membrane
  • insulation overlay
  • insulation panels and
  • the deck overlay.



Occasionally, some of these were not included in the test. When that is the case, the drop-down menu will indicate their absence with "N/A". The reader will also find a quick summary of the roof assembly, to show in very basic terms how the assembly is secured. This feature of the tables will be especially helpful when searching for a suitable PARS assembly. Note, however, that the summaries do not list specific adhesives or fasteners sizes and types; these details must be garnered from a detailed reading of the Tested Assembly report.

CSA-A123.21 and Tested Assembly Reports

The CSA-A123.21 Standard test method for the dynamic wind uplift resistance of membrane roofing systems (CSA-A123.21) is, properly speaking, a test for membrane roof systems where the membrane is exposed to the weather. Consequently, you will not find Tested Assembly reports that apply to Protected Membrane Roof Assemblies (where the membrane lies beneath the constituent components of a roof assembly). But, you will find some systems that were tested without insulation. Most of these were tested on a plywood deck, but some were tested on steel. The reader should be cognizant of these differences in systems and assemblies, and read the test report to determine the exact nature of the assembly makeup. The drop-down Summary will indicate by the absence of insulation if the system is uninsulated.

Tested Assemblies and RoofStar Guarantee Standards

Tested Assembly reports must always be read in conjunction with the RoofStar Guarantee Standards for the membrane system that is specified. For example, a roof assembly might be tested with a particular material or in a particular way that does not conform to the Standards. To conform to our Standards, some modifications to the Tested Assembly may be required, which may then preclude its use - for example, adding an insulation overlay panel where none was tested, because the assembly design requires one in order to conform to the RoofStar Guarantee Standards.

When a conflict is apparent or obvious the Design Authority may find a way to 'yes' by examining the alternative materials listed in many Tested Assembly reports. Alternatives include membranes, insulation overlays, insulation panels and roof deck overlays (commonly listed as "thermal layers"). Some materials are listed as "optional" which means that while the assembly was tested without the constituent material (a deck overlay, for example), the Design Authority may opt to use one of the materials listed in the report. Drop-down menus of the tables below (see the "View options" buttons) display Accepted Materials that can be used in each Tested Assembly.

If in doubt about how to use the Tested Assembly reports together with the RoofStar Guarantee Standards, contact the RoofStar Guarantee Program via email, or by calling (604) 882-9734.

Accepted Materials and Material Substitutions

We have selected Tested Assembly reports based on the membranes that will qualify for a RoofStar Guarantee Program, but there are tested assemblies that include one or more Secondary Materials, as for example insulation, that are not Accepted by the RoofStar Guarantee Program. Drop-down lists clearly show this by indicating when a materials is "not accepted". To ensure that the entire roof system complies with the Accepted Material requirements of the 'RoofStar Guarantee Program, follow the requirements in 3.2.1 Material Substitutions in Tested Assemblies: "When a manufacturer's Tested Assembly incorporates materials (and listed alternates) that are not part of the RoofStar Guarantee Program, the Design Authority must identify appropriate substitutions for those materials from the list of RoofStar-accepted Materials and consult the manufacturer concerning compatibility with the Tested Assembly. and direct the user to consult the membrane manufacturer in order to determine which Accepted materials will qualify as alternates."

Tested Assembly Report Data Primary Materials Other System Materials & Deck
Manufacturer Dynamic Uplift Resistance Roof
Assembly
Summary
Test Report Cap
Membrane
Base
Membrane
Plies Insulation
Overlay
Insulation Deck
Overlay
Deck
Type
kPa Psf
Click arrows to sort
IKO Industries Ltd. -1.9 -40 IKO MARS 1-A
2
Steel
IKO Industries Ltd. -4.8 -100 IKO MARS 1-B
2
Steel
IKO Industries Ltd. -2.4 -50 IKO MARS 2-A
2
Steel
IKO Industries Ltd. -3.4 -70 IKO MARS 2-B
2
Steel
IKO Industries Ltd. -5.1 -106 IKO MARS 2-C
2
Steel
IKO Industries Ltd. -2.9 -60 IKO MARS 3-A 2
Steel
IKO Industries Ltd. -3.4 -70 IKO MARS 3-B 2
Steel
IKO Industries Ltd. -6.6 -138 IKO MARS 3-C 2
Steel
IKO Industries Ltd. -4.8 -100 IKO MARS 3-D 2
Steel
IKO Industries Ltd. -5.4 -112 IKO MARS 4-A
2
Steel
Soprema Inc. -1.8 -37 SOP MARS 1-A 2 Steel
Soprema Inc. -2.3 -47 SOP MARS 1-B 2 Steel
Soprema Inc. -3.4 -70 SOP MARS 1-C 2 Steel
Soprema Inc. -2.4 -50 SOP MARS 2-A 2 Steel
Soprema Inc. -3.4 -70 SOP MARS 2-B 2 Steel
Soprema Inc. -5.2 -108 SOP MARS 2-C 2 Steel
Soprema Inc. -2 -42 SOP MARS 3-A
2 Steel
Soprema Inc. -2.4 -50 SOP MARS 3-B
2 Steel
Soprema Inc. -3.4 -70 SOP MARS 3-C
2 Steel
Soprema Inc. -6.2 -130 SOP MARS 3-D
2 Steel
Soprema Inc. -2.4 -50 SOP MARS 4-A
2 Plywood
16mm (5/8")
Soprema Inc. -1.6 -33 SOP MARS 5-A
2 Plywood
16mm (5/8")
Soprema Inc. -1.9 -40 SOP MARS 5-B
2 Plywood
16mm (5/8")
Soprema Inc. -3.2 -67 SOP MARS 5-C
2 Plywood
16mm (5/8")
Soprema Inc. -2.4 -50 SOP MARS 6-A 2 Steel
Soprema Inc. -3.4 -70 SOP MARS 6-B 2 Steel
Soprema Inc. -5.2 -108 SOP MARS 6-C 2 Steel
Soprema Inc. -2 -41 SOP MARS 7-A 1 Steel
Soprema Inc. -2.9 -60 SOP MARS 7-B 1 Steel
Soprema Inc. -4 -84 SOP MARS 7-C 1 Steel
Soprema Inc. -5.2 -108 SOP MARS 7-D 1 Steel
Soprema Inc. -1.9 -40 SOP MARS 8-A 2 Steel
Soprema Inc. -3.2 -67 SOP MARS 8-B 2 Steel
Soprema Inc. -4.8 -100 SOP MARS 8-C 2 Steel
Soprema Inc. -1.8 -37 SOP MARS 9-A 2
Steel
Soprema Inc. -2.4 -50 SOP MARS 9-B 2
Steel
Soprema Inc. -2 -42 SOP MARS 10-A
2
Steel
Soprema Inc. -2.4 -50 SOP MARS 10-B
2
Steel
Soprema Inc. -3.3 -70 SOP MARS 10-C
2
Steel
Soprema Inc. -6.2 -130 SOP MARS 10-D
2
Steel
Soprema Inc. -1.9 -40 SOP MARS 11-A 2 Steel
Soprema Inc. -3.2 -67 SOP MARS 11-B 2 Steel
Soprema Inc. -4.8 -100 SOP MARS 11-C 2 Steel
Soprema Inc. -2.4 -50 SOP MARS 12-A 2 Steel
Soprema Inc. -3.4 -70 SOP MARS 12-B 2 Steel
Soprema Inc. -5.2 -108 SOP MARS 12-C 2 Steel
Soprema Inc. -1.8 -37 SOP MARS 13-A 2 Steel
Soprema Inc. -2.4 -50 SOP MARS 13-B 2 Steel
Soprema Inc. -2 -41 SOP MARS 14-A 1 Steel
Soprema Inc. -2.9 -60 SOP MARS 14-B 1 Steel
Soprema Inc. -4 -84 SOP MARS 14-C 1 Steel
Soprema Inc. -5.2 -108 SOP MARS 14-D 1 Steel
Soprema Inc. -1.6 -33 SOP MARS 15-A
2
Plywood
16mm (5/8")
Soprema Inc. -1.9 -40 SOP MARS 15-B
2
Plywood
16mm (5/8")
Soprema Inc. -3.2 -67 SOP MARS 15-C
2
Plywood
16mm (5/8")
Tested Assembly Report Data Primary Materials Other System Materials & Deck
Manufacturer Dynamic Uplift Resistance Roof
Assembly
Summary
Test Report Membrane Plies Insulation
Overlay
Insulation Deck
Overlay
Deck
Type
kPa Psf
Carlisle Syntec Systems Canada -3.4 -70 CAR MARS 3-A 1 Steel
Carlisle Syntec Systems Canada -3.4 -71 CAR MARS 4-A 1 Steel
Elevate (formerly Firestone) -3.2 -67 FIR MARS 3-A 1
Steel
Elevate (formerly Firestone) -3.8 -80 FIR MARS 4-A 1
Steel
Elevate (formerly Firestone) -4.2 -87 FIR MARS 4-B 1
Steel
Elevate (formerly Firestone) -3.8 -80 FIR MARS 5-A 1
Steel
Elevate (formerly Firestone) -3 -63 FIR MARS 6-A 1
Steel
IKO Industries Ltd. -7.2 -150 IKO-MARS 5-A 1
Steel
IKO Industries Ltd. -5 -105 IKO-MARS 6-A 1
Steel
IKO Industries Ltd. -3.6 -75 IKO-MARS 7-A 1
Steel
IKO Industries Ltd. -5.7 -120 IKO-MARS 8-A 1
Steel
IKO Industries Ltd. -4.2 -87.5 IKO-MARS 9-A 1
Steel
IKO Industries Ltd. -4.8 -100 IKO-MARS 10-A 1
Steel
IKO Industries Ltd. -1.91 -40 IKO-MARS 11-A
1
Steel
IKO Industries Ltd. -2.9 -61 IKO-MARS 12-A
1
Steel
IKO Industries Ltd. -3.45 -72 IKO-MARS 13-A 1
Steel
IKO Industries Ltd. -2.7 -56.6 IKO-MARS 14-A
1
Steel
IKO Industries Ltd. -2.28 -47.5 IKO-MARS 15-A 1
Steel
Johns Manville Corp. -3.6 -75 JM MARS 3-A 1
Steel
Johns Manville Corp. -5 -105 JM MARS 4-A 1
Steel
Tested Assembly Report Data Primary Materials Other System Materials & Deck
Manufacturer Dynamic Uplift Resistance Roof
Assembly
Summary
Test Report Membrane Plies Insulation
Overlay
Insulation Deck
Overlay
Deck
Type
kPa Psf
Carlisle Syntec Systems Canada -3.4 -70 CAR MARS 1-A 1 Steel
Carlisle Syntec Systems Canada -2.3 -47 CAR MARS 2-A 1 Steel
Johns Manville Corp. -3.6 -75 JM AARS 1-A 1
Steel
Johns Manville Corp. -3.6 -75 JM AARS 2-A 1
Steel

2 PARS

The tables on the adjacent tabs display data and links to Tested Assembly Reports listed by the membrane type shown on the tab. Dynamic Wind Uplift (DUR) values are shown in sortable columns; to sort a column, click the column heading. You may also sort the data by manufacturer (click the column heading). Deck types that were tested with the Assembly are shown in the far right column.

Tested Assembly Report Data Primary Materials Other System Materials & Deck
Manufacturer Dynamic Uplift Resistance Roof
Assembly
Summary
Test Report Cap
Membrane
Base
Membrane
Plies Insulation
Overlay
Insulation Deck
Overlay
Deck
Type
kPa Psf
Click arrows to sort
Elevate (formerly Firestone) -2.1 -45 FIR PARS 1-A 2
Steel
Garland Canada Inc. -2.2 -46 GAR PARS 1-A 2
Steel
Garland Canada Inc. -2.2 -46 GAR PARS 2-A 2
Steel
Garland Canada Inc. -2.2 -46 GAR PARS 3-A 2
Steel
Henry Company Canada -4.67 -97.5 HEN PARS 1-A
2
Steel
IKO Industries Ltd. -1.4 -29.0 IKO PARS 1-A 2
Steel
IKO Industries Ltd. -2.3 -48.0 IKO PARS 2-A 2
Steel
IKO Industries Ltd. -1.8 -37.5 IKO PARS 3-A 2
Steel
IKO Industries Ltd. -3.6 -75 IKO PARS 4-A 2
Steel
IKO Industries Ltd. -3 -62 IKO PARS 5-A 2
Steel
IKO Industries Ltd. -2.4 -50 IKO PARS 6-A 2
Steel
IKO Industries Ltd. -1.4 -30 IKO PARS 7-A 2
Steel
IKO Industries Ltd. -2.4 -50 IKO PARS 8-A 2
Steel
IKO Industries Ltd. -2.4 -50 IKO PARS 9-A 2
Steel
IKO Industries Ltd. -2.2 -47 IKO PARS 13-A 2
Steel
IKO Industries Ltd. -4.2 -80 IKO PARS 14-A 2
Steel
IKO Industries Ltd. -1.9 -40 IKO PARS 15-A 2
Steel
IKO Industries Ltd. -1.9 -40 IKO PARS 16-A 2
Steel
IKO Industries Ltd. -6.7 -140 IKO PARS 17-A 2
Steel
IKO Industries Ltd. -3.0 -62 IKO PARS 18-A
2
Steel
IKO Industries Ltd. -3.6 -75 IKO PARS 19-A 2
Steel
IKO Industries Ltd. -4.1 -85 IKO PARS 20-A 2
Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 1-A 2 or 3
Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 2-A 2 or 3
Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 3-A 2 or 3 Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 4-A 2 or 3 Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 5-A 2 or 3 Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 6-A 2 or 3 Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 7-A 2 or 3 Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 8-A 2 or 3
Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 9-A 2 or 3
Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 10-A 2 or 3
Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 11-A 2 or 3
Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 12-A 2 or 3 Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 13-A 2 or 3
Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 14-A 2 or 3 Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 15-A 2 or 3
Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 15-A 2 or 3 Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 17-A 2 or 3 Steel
Polyglass USA, Inc. -3.1 -64 POL PARS 18-A 2 or 3 Steel
Polyglass USA, Inc. -3.4 -70 POL PARS 19-A 2 or 3 Steel
Polyglass USA, Inc. -1.4 -30 POL PARS 20-A 2 or 3
Steel
Polyglass USA, Inc. -1.8 -38 POL PARS 21-A 2 or 3
Steel
Polyglass USA, Inc. -3.4 -72 POL PARS 22-A 2 or 3 Steel
Polyglass USA, Inc. -3.4 -72 POL PARS 23-A 2 or 3 Steel
Siplast, Inc. -1.9 -40 SIP PARS 1-A
2
Steel
Siplast, Inc. -1.4 -30 SIP PARS 2-A
2
Plywood
16mm (5/8")
Siplast, Inc. -2.23 -46.67 SIP PARS 3-A
2
Steel
Siplast, Inc. -1.8 -37 SIP PARS 4-A
2
Steel
Siplast, Inc. -2.86 -60 SIP PARS 5-A
2
Steel
Siplast, Inc. -2.9 -60 SIP PARS 6-A
2
Steel
Siplast, Inc. -1.46 -30 SIP PARS 7-A
2
Steel
Siplast, Inc. -2.9 -60 SIP PARS 8-A 2
Steel
Siplast, Inc. -2.9 -60 SIP PARS 9-A 2 Steel
Siplast, Inc. -2.3 -47 SIP PARS 10-A 2
Plywood
16mm (5/8")
Siplast, Inc. -3.7 -77 SIP PARS 11-A 2 Plywood
16mm (5/8")
Siplast, Inc. -2.5 -53 SIP PARS 12-A 2
Plywood
16mm (5/8")
Siplast, Inc. -3.5 -73 SIP PARS 13-A 2
Steel
Siplast, Inc. -2 -42 SIP PARS 14-A
2 Steel
Siplast, Inc. -1.8 -38 SIP PARS 15-A 2
Steel
Soprema Inc. -1.4 -30 SOP PARS 1-A 2
Steel
Soprema Inc. -2.3 -48 SOP PARS 1-B 2
Steel
Soprema Inc. -2.8 -58 SOP PARS 1-C 2
Steel
Soprema Inc. -2.9 -60 SOP PARS 2-A 2
Steel
Soprema Inc. -1.4 -30 SOP PARS 3-A 2
Steel
Soprema Inc. -2.3 -48 SOP PARS 3-B 2
Steel
Soprema Inc. -2.8 -58 SOP PARS 3-C 2
Steel
Soprema Inc. -3.4 -70 SOP PARS 3-D 2
Steel
Soprema Inc. -1.8 -37 SOP PARS 4-A 2 Steel
Soprema Inc. -3 -62 SOP PARS 4-B 2 Steel
Soprema Inc. -2.2 -45 SOP PARS 5-A 2 Steel
Soprema Inc. -3.6 -75 SOP PARS 5-B 2 Steel
Soprema Inc. -5 -105 SOP PARS 5-C 2 Steel
Soprema Inc. -5.6 -117 SOP PARS 6-A
2
Steel
Soprema Inc. -1.9 -40 SOP PARS 7-A
2
Steel
Soprema Inc. -3.6 -75 SOP PARS 8-A
2
Steel
Soprema Inc. -1.8 -37 SOP PARS 9-A
2
Steel
Soprema Inc. -5.7 -120 SOP PARS 10-A
2
Steel
Soprema Inc. -2.4 -50 SOP PARS 11-A
2
Steel
Soprema Inc. -3.6 -75 SOP PARS 12-A
2 Steel
Soprema Inc. -2.3 -48 SOP PARS 13-A
2 Steel
Soprema Inc. -3.2 -67 SOP PARS 14-A
2
Steel
Soprema Inc. -1.8 -37 SOP PARS 15-A 2
Plywood
16mm (5/8")
Soprema Inc. -3 -62 SOP PARS 15-B 2
Plywood
16mm (5/8")
Soprema Inc. -4 -83 SOP PARS 16-A
2
Steel
Soprema Inc. -2.9 -60 SOP PARS 17-A
2
Steel
Soprema Inc. -4 -83 SOP PARS 18-A
2 Steel
Soprema Inc. -5.7 -120 SOP PARS 19-A
2 Steel
Soprema Inc. -2.9 -60 SOP PARS 20-A 2
Steel
Soprema Inc. -1.9 -40 SOP PARS 21-A
2
Steel
Soprema Inc. -2.9 -60 SOP PARS 21-B
2
Steel
Soprema Inc. -3.9 -81 SOP PARS 22-A
2 Steel
Soprema Inc. -2.9 -60 SOP PARS 23-A
2
Steel
Tested Assembly Report Data Primary Materials Other System Materials & Deck
Manufacturer Dynamic Uplift Resistance Roof
Assembly
Summary
Test Report Membrane Plies Insulation
Overlay
Insulation Deck
Overlay
Deck
Type
kPa Psf
Carlisle Syntec Systems Canada -1.8 -37.5 CAR PARS 1-A 1
Steel
Elevate (formerly Firestone) -2.1 -45 FIR PARS 2-A 1
Steel
Elevate (formerly Firestone) -3.2 -67 FIR PARS 3-A 1
Steel
Tested Assembly Report Data Primary Materials Other System Materials & Deck
Manufacturer Dynamic Uplift Resistance Roof
Assembly
Summary
Test Report Membrane Plies Insulation
Overlay
Insulation Deck
Overlay
Deck
Type
kPa Psf
Carlisle Syntec Systems Canada -1.7 -35 CAR PARS 3-A 1
Steel
Elevate (formerly Firestone) -2.9 -60 FIR PARS 4-A 1
Steel
Elevate (formerly Firestone) -3.2 -67 FIR PARS 5-A 1
Steel
IKO Industries Ltd. -4.9 -100 IKO-PARS 21-A 1
Steel
IKO Industries Ltd. -3.4 -70 IKO-PARS 22-A 1
Steel
IKO Industries Ltd. -4.9 -100 IKO-PARS 23-A 1
Steel
Tested Assembly Report Data Primary Materials Other System Materials & Deck
Manufacturer Dynamic Uplift Resistance Roof
Assembly
Summary
Test Report Membrane Plies Insulation
Overlay
Insulation Deck
Overlay
Deck
Type
kPa Psf
IKO Industries Ltd. -3.6 -75 IKO PARS 10-A 4
Steel
IKO Industries Ltd. -2.9 -60 IKO PARS 11-A 4
Steel

3 AARS

The tables on the adjacent tabs display data and links to Tested Assembly Reports listed by the membrane type shown on the tab. Dynamic Wind Uplift (DUR) values are shown in sortable columns; to sort a column, click the column heading. You may also sort the data by manufacturer (click the column heading). Deck types that were tested with the Assembly are shown in the far right column.

Tested Assembly Report Data Primary Materials Other System Materials & Deck
Manufacturer Dynamic Uplift Resistance Roof
Assembly
Summary
Test Report Cap
Membrane
Base
Membrane
Plies Insulation
Overlay
Insulation Deck
Overlay
Deck
Type
kPa Psf
Click arrows to sort
Henry Company Canada -3.83 -80 HEN AARS 1-A 2
Steel
Henry Company Canada -4.79 -100 HEN AARS 2-A 2 Steel
IKO Industries Ltd. -4.8 -100 IKO AARS 1-A 2
Steel
IKO Industries Ltd. -2.4 -50 IKO AARS 2-A 2
Steel
IKO Industries Ltd. -4.2 -87 IKO AARS 3-A 2
Steel
IKO Industries Ltd. -4.2 -87 IKO AARS 4-A 2
Steel
IKO Industries Ltd. -4.8 -100 IKO AARS 5-A 2
Steel
IKO Industries Ltd. -2.4 -50 IKO AARS 6-A 2
Steel
IKO Industries Ltd. -4.2 -87 IKO AARS 7-A 2
Steel
IKO Industries Ltd. -3.8 -80 IKO AARS 8-A 2
Steel
IKO Industries Ltd. -2.4 -50 IKO AARS 9-A 2
Steel
IKO Industries Ltd. -3.8 -80 IKO AARS 10-A
2
Steel
IKO Industries Ltd. -3.4 -70 IKO AARS 12-A
2
Steel
IKO Industries Ltd. -3 -62.5 IKO AARS 13-A 2
Steel
IKO Industries Ltd. -4.8 -100 IKO AARS 14-A 2
Steel
IKO Industries Ltd. -4.8 -100 IKO AARS 15-A 2
Steel
IKO Industries Ltd. -3 -62.5 IKO AARS 16-A
2
Steel
IKO Industries Ltd. -4.2 -87 IKO AARS 17-A 2
Steel
IKO Industries Ltd. -3.6 -75 IKO AARS 18-A 2
Steel
IKO Industries Ltd. -5.5 -115 IKO AARS 19-A 2
Plywood
17mm (5/8")
IKO Industries Ltd. -5.5 -115 IKO AARS 20-A 2
Plywood
17mm (5/8")
IKO Industries Ltd. -3.6 -75 IKO AARS 21-A
2
Steel
IKO Industries Ltd. -7.2 -150 IKO AARS 22-A
2
Plywood
17mm (5/8")
IKO Industries Ltd. -5.5 -115 IKO AARS 23-A 2
Steel
IKO Industries Ltd. -5.9 -122.5 IKO AARS 24-A 2
Steel
Siplast, Inc. -2.87 -60 SIP AARS 1-A
2
Steel
Siplast, Inc. -3.35 -70 SIP AARS 2-A
2
Steel
Siplast, Inc. -3.4 -70 SIP AARS 3-A 2
Steel
Siplast, Inc. -2.3 -47 SIP AARS 4-A 2
Steel
Siplast, Inc. -1.9 -40 SIP AARS 5-A 2
Steel
Siplast, Inc. -3.9 -82 SIP AARS 6-A 2 Steel
Siplast, Inc. -5.2 -109 SIP AARS 7-A 2
Steel
Siplast, Inc. -1.4 -30 SIP AARS 8-A 2
Plywood
15mm (19/32")
Soprema Inc. -4.3 -87.3 SOP AARS 1-A 2
Steel
Soprema Inc. -4 -83.3 SOP AARS 2-A 2
Plywood
17mm (5/8")
Soprema Inc. -2.9 -60 SOP AARS 3-A
2
Steel
Soprema Inc. -3 -63 SOP AARS 4-A 2
Steel
Soprema Inc. -2.4 -50 SOP AARS 5-A 2
Steel
Soprema Inc. -3 -63 SOP AARS 6-A 2
Steel
Soprema Inc. -4.3 -90 SOP AARS 7-A 2 Steel
Soprema Inc. -3.4 -72 SOP AARS 8-A 2
Steel
Soprema Inc. -4.8 -100 SOP AARS 8-B 2
Steel
Soprema Inc. -3 -62 SOP AARS 9-A 2
Steel
Soprema Inc. -2.4 -50 SOP AARS 10-A 2
Steel
Soprema Inc. -3.9 -83 SOP AARS 10-B 2
Steel
Soprema Inc. -4.6 -96 SOP AARS 10-C 2
Steel
Soprema Inc. -1.9 -40 SOP AARS 11-A 2
Steel
Soprema Inc. -3.9 -83 SOP AARS 11-B 2
Steel
Soprema Inc. -3.6 -75 SOP AARS 12-A 2
Steel
Soprema Inc. -4.2 -87 SOP AARS 12-B 2
Steel
Soprema Inc. -4.3 -90 SOP AARS 12-C 2
Steel
Soprema Inc. -3.6 -75 SOP AARS 13-A 2 Steel
Soprema Inc. -3.8 -80 SOP AARS 13-B 2 Steel
Soprema Inc. -2.4 -50 SOP AARS 14-A 2
Steel
Soprema Inc. -2.4 -50 SOP AARS 15-A 2
Steel
Soprema Inc. -4.2 -87 SOP AARS 16-A 2
Steel
Soprema Inc. -4.3 -90 SOP AARS 16-B 2
Steel
Soprema Inc. -4 -83 SOP AARS 17-A 2
Plywood
19mm (3/4")
Soprema Inc. -2.4 -50 SOP AARS 18-A
2
Steel
Soprema Inc. -2.4 -50 SOP AARS 18-B
2
Steel
Soprema Inc. -3.4 -72 SOP AARS 19-A 2
Steel
Soprema Inc. -4.8 -100 SOP AARS 19-B 2
Steel
Soprema Inc. -4.3 -90 SOP AARS 20-A 2 Steel
Soprema Inc. -3 -63 SOP AARS 21-A
2 Steel
Soprema Inc. -1.8 -37 SOP-AARS 22-A
2 Steel
Soprema Inc. -1.9 -40 SOP-AARS 22-B
2 Steel
Soprema Inc. -2.4 -50 SOP-AARS 22-C
2 Steel
Soprema Inc. -3.4 -70 SOP-AARS 23-A
2 Steel
Soprema Inc. -2.4 -50 SOP-AARS 24-A
2 Steel
Soprema Inc. -3.6 -75 SOP-AARS 25-A
2
Steel
Soprema Inc. -2.4 -50 SOP-AARS 26-A
2
Steel
Tremco Ltd. -2.5 -53 TRE AARS 1-A 2
Steel
Tremco Ltd. -1.4 -29 TRE AARS 2-A 2
Steel
Tested Assembly Report Data Primary Materials Other System Materials & Deck
Manufacturer Dynamic Uplift Resistance Roof
Assembly
Summary
Test Report Membrane Plies Insulation
Overlay
Insulation Deck
Overlay
Deck
Type
kPa Psf
Elevate (formerly Firestone) -2 -41 FIR AARS 1-A 1
Steel
Tested Assembly Report Data Primary Materials Other System Materials & Deck
Manufacturer Dynamic Uplift Resistance Roof
Assembly
Summary
Test Report Membrane Plies Insulation
Overlay
Insulation Deck
Overlay
Deck
Type
kPa Psf
Elevate (formerly Firestone) -2.4 -50 FIR AARS 2-A 1
Steel
IKO Industries Ltd. -4.19 -87.5 IKO-AARS 25-A 1
Steel
IKO Industries Ltd. -2.39 -50 IKO-AARS 26-A 1
Steel

No Tested Assemblies submitted

Tested Assembly Report Data Primary Materials Other System Materials & Deck
Manufacturer Dynamic Uplift Resistance Roof
Assembly
Summary
Test Report Membrane Plies Insulation
Overlay
Insulation Deck
Overlay
Deck
Type
kPa Psf
IKO Industries Ltd. -4.9 -100 IKO AARS 11-A 4
Steel

Home

© RCABC 2020
No reproduction of these Standards, in whole or in part, is lawful without the expressed permission of the RGC Guarantee Program.