;'''Product Summary''':
+
;'''Product Summary''': Polyisocyanurate '''H-Shield Premier''' is a foam core insulation board covered on both sides with a medium weight fiber-glass reinforced facer. This dimensionally stable, durable insulation offers maximum thermal efficiency. Hunter Panels Polyisocyanurate '''H-Shield Premier''' insulation is UL and FM approved as a system component in certain roofing assemblies. Polyisocyanurate H-Shield Premier is also available in tapered form. The industry follows CAN / ULC-S770 test method for determining a 15-year time-weighted average Long Term Thermal Resistance (LTTR).
Polyisocyanurate '''H-Shield Premier''' is a foam core insulation board covered on both sides with a medium weight fiber-glass reinforced facer. This dimensionally stable, durable insulation offers maximum thermal efficiency. Hunter Panels Polyisocyanurate '''H-Shield Premier''' insulation is UL and FM approved as a system component in certain roofing assemblies. Polyisocyanurate H-Shield Premier is also available in tapered form. The industry follows CAN / ULC-S770 test method for determining a 15-year time-weighted average Long Term Thermal Resistance (LTTR).  
+
 
 +
:<u>TYPICAL PROPERTIES AND CHARACTERISTICS:</u>
 +
 
 +
:<table border=0 cellpadding=5 cellspacing=0>
 +
<tr>
 +
<td>Nominal Thickness inches (mm)</td><td>&bull; 1.0 (25)</td>
 +
</tr>
 +
<tr>
 +
<td>LTTR R-Value*</td><td>&bull; 6.0</tD>
 +
</tr>
 +
<tr>
 +
<td>LTTR C-Value*</td><td>&bull; 0.167</tD>
 +
</tr>
 +
<tr>
 +
<td>T-Load Quantity Sq. Ft. (Sq. M.)</td><td>&bull; 32,384 (3,009)</tD>
 +
</tr>
 +
<tr>
 +
<td>Flute Span Ability, in. (mm)</td><td>&bull; 2-5/8 (67)</tD>
 +
</tr>
 +
<tr>
 +
<td>Minimum Thickness, in (mm)</td><td>&bull; 0.95 (24)</tD>
 +
</tr>
 +
</table>
 +
 
 +
 
 +
<u>PHYSICAL PROPERTIES:</u>
 +
<table border=0 cellpadding=5 cellspacing=0>
 +
<tr>
 +
<td><u>Property</u></td><td><u>Test Method</u></td><td><u>Specification Limits</u></td>
 +
</tr>
 +
<tr>
 +
<td>Compressive Strength, psi (kPa)</td><td>ASTM D1621 Procedure A</td><td>Minimum 20 (138)</td>
 +
</tr>
 +
<tr>
 +
<td>Moisture Vapour Transmission, perms</td><td>ASTM C355</td><td>Maximum 1.0</td>
 +
</tr>
 +
<tr>
 +
<td>Foam core Density, lb / ft<sup>3</sup> (kg / m<sup>3</sup>)</td><td>ASTM D1622</td><td>Nominal 2.0 (32)</td>
 +
</tr>
 +
<tr>
 +
<td>Flame Spread (foam core)</td><td>ASTM E84</td><td>Maximum 25</td>
 +
</tr>
 +
<tr>
 +
<td>Service Temperature, range if &#186;F (&#186;C)</td><td>- - -</td><td>-100 (-73) to 250 (121)</td>
 +
</tr>
 +
</table>
 +
 
 +
Hunter Panels Polyisocyanurate H-Shield Premier meets or exceeds ASTM C1289 (Type II, Class 1, Grade 2) and Federal Specification HH-I-1972/2.
 
|}
 
|}
  

Latest revision as of 21:47, 3 November 2016

Notice to the Reader:

The roofing assembly / material information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications. The preparation of a detailed specification is the responsibility of the design authority.

Manufacturer: Hunter Panels
Accepted for RoofStar Guarantee Program
Date TBA
Product Summary
Polyisocyanurate H-Shield Premier is a foam core insulation board covered on both sides with a medium weight fiber-glass reinforced facer. This dimensionally stable, durable insulation offers maximum thermal efficiency. Hunter Panels Polyisocyanurate H-Shield Premier insulation is UL and FM approved as a system component in certain roofing assemblies. Polyisocyanurate H-Shield Premier is also available in tapered form. The industry follows CAN / ULC-S770 test method for determining a 15-year time-weighted average Long Term Thermal Resistance (LTTR).
TYPICAL PROPERTIES AND CHARACTERISTICS:
Nominal Thickness inches (mm)• 1.0 (25)
LTTR R-Value*• 6.0
LTTR C-Value*• 0.167
T-Load Quantity Sq. Ft. (Sq. M.)• 32,384 (3,009)
Flute Span Ability, in. (mm)• 2-5/8 (67)
Minimum Thickness, in (mm)• 0.95 (24)


PHYSICAL PROPERTIES:

PropertyTest MethodSpecification Limits
Compressive Strength, psi (kPa)ASTM D1621 Procedure AMinimum 20 (138)
Moisture Vapour Transmission, permsASTM C355Maximum 1.0
Foam core Density, lb / ft3 (kg / m3)ASTM D1622Nominal 2.0 (32)
Flame Spread (foam core)ASTM E84Maximum 25
Service Temperature, range if ºF (ºC)- - --100 (-73) to 250 (121)

Hunter Panels Polyisocyanurate H-Shield Premier meets or exceeds ASTM C1289 (Type II, Class 1, Grade 2) and Federal Specification HH-I-1972/2.