Search results

  • <i>Product Group:</i> <b>BUILT-UP ROOFING SYSTEMS EXPOSED MEMBRANES, INSULATED </b> ...mat used in GAF’s membranes provides excellent tensile strength. The GAF membranes are fully adhered with hot asphalt to prepared surfaces.
    25 KB (3,685 words) - 16:52, 4 November 2016
  • <i>Product Group:</i> <b>SBS MODIFIED PROPRIETARY BUR SYSTEM</b> ...land Company is a leading manufacturer and distributor of high-performance roofing and flooring solutions for commercial, industrial, and public properties. W
    22 KB (3,005 words) - 17:17, 4 November 2016
  • Product Group: <b>SBS MODIFIED BITUMINOUS WATERPROOFING MEMBRANES</b> ...membranes and the high performance composite systems, all tough, flexible SBS polymer modified bitumen prefabricated sheets, appropriately reinforced an
    7 KB (1,060 words) - 18:29, 9 November 2016
  • ...eaves, walls, vents, etc. must be sealed to prevent moisture from entering roofing or between plies of stripping. ...installing a BUR system employing modified bitumen membranes, only factory cap sheets are to be used on slopes exceeding 1:24 (1/2" in 12"). Manufacturers
    14 KB (2,005 words) - 21:35, 25 January 2017
  • ...he roofing assembly, be it membrane, ballast or growing medium (soil). All membrane flashing (stripping) terminating on a vertical surface must be mechanically ...s tested to and compliant with [[RoofStar Guarantee Standards for SBS Roof Systems#SBS4| '''CSA A123.21''']] (latest edition), and include a calculation for t
    12 KB (1,724 words) - 21:46, 16 February 2018
  • ...rsion in water with the exception of protected and modified protected roof systems. ...tripping plies shall be two overlapping plies of a minimum 2 mm reinforced SBS modified bitumen base sheet or two overlapping plies of a minimum 180 g / m
    10 KB (1,568 words) - 22:02, 7 March 2018
  • <big><big><big><big><big>Standard for Grade-level Waterproofing Systems</big></big></big></big></big> ...spaces, subsequently this makes <b><i>waterproofing and protected roofing systems,</i></b> not dampproofing, the only reliable options to prevent the passage
    117 KB (13,068 words) - 18:35, 5 April 2024
  • ...brane flashing must be in keeping with the Standards in '''11.3.3.3 Liquid Membrane Flashing''' || 2020-October-22 }}. <li>With the exception of ''overflows'', ''scupper drains'' and membrane gutters, roof drains and penetration flashings for new construction ''proje
    56 KB (8,120 words) - 20:44, 19 May 2022
  • ...brane flashing must be in keeping with the Standards in '''11.3.3.3 Liquid Membrane Flashing'''. <li>{{hilite | With the exception of ''overflows'', ''scupper drains'' and membrane gutters, roof drains and penetration flashings for new construction ''proje
    45 KB (6,830 words) - 19:36, 11 March 2022
  • ...brane flashing must be in keeping with the Standards in '''11.3.3.3 Liquid Membrane Flashing'''. <li>{{hilite | With the exception of ''overflows'', ''scupper drains'' and membrane gutters, roof drains and penetration flashings for new construction ''proje
    45 KB (6,811 words) - 20:28, 9 July 2021
  • ...brane flashing must be in keeping with the Standards in '''11.3.3.3 Liquid Membrane Flashing''' || 2020-October-22 }}. <li>With the exception of ''overflows'', ''scupper drains'' and membrane gutters, roof drains and penetration flashings for new construction ''proje
    56 KB (8,117 words) - 15:53, 27 August 2021
  • ...ig><big><big><big>Notes to Standard for SBS-modified Bitumen Membrane Roof Systems</big></big></big></big></big> :<big>'''A-1.1.3.1.'''</big> ('''Permitted Roof Systems''')
    61 KB (8,812 words) - 18:01, 2 April 2024
  • <big><big><big><big><big>Roof Membranes</big></big></big></big></big> ...he accepted membrane manufacturer's written submissions. In all cases, the membrane manufacturer should be contacted for further recommendations and details.
    33 KB (4,674 words) - 16:01, 9 September 2021
  • <big>Water-shedding Roof Systems: Metals</big><br> <big><big><big><big><big>Standard for Architectural Sheet Metal (ASM) Roof Systems</big></big></big></big></big>
    260 KB (36,048 words) - 21:32, 5 April 2024
  • <big>Waterproofing Roof Systems: Flexible Membranes (Polymer-modified Bituminous)</big><br> <big><big><big><big><big><big>Standard for SBS-modified Bitumen Membrane Roof Systems</big></big></big></big></big></big>
    465 KB (62,115 words) - 14:08, 16 May 2024
  • <big>Waterproofing Roof Systems: Thermoset Membranes</big><br> <big><big><big><big><big><big>Standard for EPDM Membrane Roof Systems</big></big></big></big></big></big>
    423 KB (57,312 words) - 21:21, 5 April 2024
  • <big>Waterproofing Roof Systems: Thermosplastic Membranes</big><br> <big><big><big><big><big><big>Standard for TPO Membrane Roof Systems</big></big></big></big></big></big>
    420 KB (56,956 words) - 21:23, 5 April 2024
  • <big>Waterproofing Roof Systems: Thermosplastic Membranes</big><br> <big><big><big><big><big><big>Standard for PVC Membrane Roof Systems</big></big></big></big></big></big>
    415 KB (56,426 words) - 21:31, 5 April 2024
  • <big>Water-shedding Roof Systems: Bituminous</big><br> <big><big><big><big><big>Standard for Asphalt Shingle Roof Systems</big></big></big></big></big>
    235 KB (33,160 words) - 21:33, 5 April 2024
  • <big>Waterproofing Roof Systems: Liquid Membranes</big><br> ...<big><big><big><big>Standard for Hot Fluid-applied Rubberized Asphalt Roof Systems</big></big></big></big></big></big>
    294 KB (41,687 words) - 21:32, 5 April 2024

View (previous 20 | next 20) (20 | 50 | 100 | 250 | 500)