Search results

Jump to: navigation, search

Search results

  • ...formation page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Divisio ...ree of "humps" or depressions. These can counteract any sloped insulation systems installed by the roofing contractor and cause ponding. On new construction
    20 KB (2,969 words) - 16:06, 9 September 2021
  • <span class="reference">When any portion of a waterproofing system is installed with heat, the work is classified as Hot Work. Some to ==Contractor Qualifications for Roof and Grade-level Waterproofing==
    11 KB (1,608 words) - 22:03, 3 May 2021
  • ...Systems''', '''Water-shedding Systems''', and '''Grade-level Waterproofing Systems'''. Explanatory notes may be incorporated at the end of each Standard. ...Waterproofing Roof Systems" is a Group; "Polymer-modified Bitumen Membrane Systems" is a System type). Each Standard published in the RPM is an arrangement o
    15 KB (2,132 words) - 19:02, 18 August 2023
  • [[File:Low-slope Roof Insulation.jpg|300 px]] ...formation page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Divisio
    23 KB (3,279 words) - 15:42, 9 September 2021
  • ...b> and shall be installed on the top surface of all waterproofing membrane systems designed with inaccessible overburdens and wearing courses. The exceptions ...terproofing membranes, testing shall be conducted prior to installation of insulation and overburdens and be performed to ASTM D5957 - 98.
    2 KB (249 words) - 22:45, 9 November 2016
  • <big><big><big><big><big>Insulation Joints and Overlays</big></big></big></big></big> ...formation page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Divisio
    4 KB (532 words) - 15:44, 9 September 2021
  • ...ish or a sanded finish. PERMA-BOARD is compatible with all asphalt roofing systems and is unaffected by moisture and will not rot. ...may be heat welded or hot mopped directly to PERMA-BOARD, creating a thick waterproofing layer. The asphalt board becomes an integral part of the roof membrane maki
    3 KB (361 words) - 22:21, 3 November 2016
  • ...formation page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Divisio ...materials due to thermal and moisture variations. Traditionally, the roof insulation and roofing are secured to the roof deck by means of mechanical fastening,
    7 KB (999 words) - 15:42, 9 September 2021
  • ...formation page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Divisio ...heat and reverting to more solid material as they cool. Their adhesive and waterproofing properties have been utilized in construction for hundreds of years. The mo
    15 KB (2,293 words) - 15:33, 9 September 2021
  • <big><big><big><big><big>Protected and Modified Protected Roof Systems</big></big></big></big></big> ...formation page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Divisio
    11 KB (1,624 words) - 16:21, 9 September 2021
  • ;(1) [[SBS Roof Systems Standard#PART_9|'''Base Membrane (field)''']]: See Tables '''9.1''' and ''' ...flashing must extend up the vertical plane, and above the ''Finished Roof/Waterproofing Surface'', at least 200 mm (8”), and must extend onto the roof field at l
    5 KB (661 words) - 17:37, 27 October 2023
  • ...ata is also included on flexible membrane (&#8220;non-conventional&#8221;) systems as applicable. * Insulation to replace any wet materials discovered in cuts
    75 KB (11,617 words) - 21:00, 3 September 2021
  • ...roofing materials and components, such as single-ply membranes, flashings, insulation boards, etc. Before adhesives are applied, their compatibility with other ...urement (for more on this subject, refer to Article 3.1.3.4. in any of the waterproofing roof Standards for sheet membrane roofs, published in Division B of the RPM
    76 KB (11,565 words) - 18:09, 26 January 2024
  • <u>Built-Up Roofing Systems Design Guide</u>. Rockville, MA: The Asphalt Roofing Manufacturers Associat <u>Design and Specification of Roofing Systems</u>. Englewood, CO: Roofing Industry Educational Institute, Seminar Manual.
    4 KB (548 words) - 14:32, 18 August 2023
  • === [[RoofStar Guarantee Standards for EPDM Membrane Systems#EPDMVAPOUR|Air and Vapour Control]] === ...bc.org/index.php?title=Low_Slope_Membrane_Roofs '''Low Slope Membrane Roof Systems''']. This cross-reference is listed for information only.
    5 KB (633 words) - 20:30, 26 July 2021
  • === [[RoofStar Guarantee Standards for TPO Membrane Systems#TPOVAPOUR|Air and Vapour Control]] === ...bc.org/index.php?title=Low_Slope_Membrane_Roofs '''Low Slope Membrane Roof Systems''']. This cross-reference is listed for information only.
    5 KB (614 words) - 20:30, 26 July 2021
  • ...sulation that is specifically designed to provide high quality, economical insulation for conventional roofs, with single-ply, two-ply or four-ply roof membranes ...ilitating the flow of water infiltrated under the insulating boards to the waterproofing system's surface and drains.
    3 KB (353 words) - 17:41, 13 October 2016
  • ...sulation that is specifically designed to provide high quality, economical insulation for conventional roofs, with single-ply, two-ply or four-ply roof membranes ...ilitating the flow of water infiltrated under the insulating boards to the waterproofing system's surface and drains.
    3 KB (353 words) - 17:42, 13 October 2016
  • ...sulation that is specifically designed to provide high quality, economical insulation for conventional roofs, with single-ply, two-ply or four-ply roof membranes ...ilitating the flow of water infiltrated under the insulating boards to the waterproofing system's surface and drains.
    3 KB (353 words) - 17:42, 13 October 2016
  • ...sulation that is specifically designed to provide high quality, economical insulation for conventional roofs, with single-ply, two-ply or four-ply roof membranes ...ilitating the flow of water infiltrated under the insulating boards to the waterproofing system's surface and drains.
    3 KB (353 words) - 17:42, 13 October 2016

View (previous 20 | next 20) (20 | 50 | 100 | 250 | 500)