  • ...r performance and versatility of a flexible membrane, SBS-modified roofing membranes are also generally compatible with asphalt products, and are therefore usef ...rface coating, such as stone or ceramic granules. The performance of these membranes (for example, their flexibility or ability to retain their shape under high
    0 members (0 subcategories, 0 files) - 16:30, 23 June 2015
  • ...Year or Ten (10) Year Roofing Guarantee, and for a RoofStar Five (5) Year Waterproofing Guarantee.</big> ...uilt-up roofing systems (BUR) incorporating organic and glass felt primary membranes.
    4 KB (526 words) - 16:18, 17 March 2019
  • ...and modified bituminous membranes represent a large share of the flexible membranes that have replaced traditional built-up roofing felts. While offering the ...r performance and versatility of a flexible membrane, SBS-modified roofing membranes are also generally compatible with asphalt products, and are therefore usef
    22 KB (3,281 words) - 21:46, 17 July 2017
  • <big><big>'''Waterproofing Roofs'''</big></big> <big><big>'''Waterproofing Roofs'''</big></big>
    3 KB (432 words) - 21:52, 28 March 2024
  • ..., TPO, PVC) single ply membranes used for Landscaped and Vegetated roofing systems shall be fully adhered and a minimum thickness of 1.5mm (0.060"). || 2018-J ...on that is situated on top of, and covering all or a portion of, a roof or waterproofing membrane assembly. This excludes thermal insulation but includes, and is n
    21 KB (2,722 words) - 14:55, 25 September 2017
  • ..., TPO, PVC) single ply membranes used for Landscaped and Vegetated roofing systems shall be fully adhered and a minimum thickness of 1.5mm (0.060"). || 2018-J ...ed_and_Modified_Protected_Roof_Systems '''Protected and Modified Protected Membranes'''] and additional requirements set out below in '''10.1.2'''. || 2018-Janu
    21 KB (2,856 words) - 22:57, 9 November 2018
  • <big>Waterproofing Roof Systems: Thermosplastic Membranes</big><br> <big><big><big><big><big><big>Standard for TPO Membrane Roof Systems</big></big></big></big></big></big>
    421 KB (57,062 words) - 22:20, 5 April 2024
  • <tab name="Materials for Waterproofing Roof Systems"> <big><big>'''Primary Materials: Membranes'''</big></big>
    13 KB (1,636 words) - 17:02, 5 January 2024
  • === Accepted Materials for Low Slope Roofs === :[[Accepted Materials - SBS Roofing|Accepted Materials - SBS Roofing Systems]]
    1 KB (134 words) - 15:45, 8 January 2016
  • <big><big><big><big><big>Waterproofing Materials</big></big></big></big></big> ...formation page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Divisio
    23 KB (3,307 words) - 15:57, 9 September 2021
  • :To cause two surfaces to be held together by adhesion. Single-ply membranes are often &#8220;partially&#8221; or &#8220;totally adhered&#8221; to a sub ...ere or attach various roofing materials and components, such as single-ply membranes, flashings, insulation boards, etc. Before adhesives are applied, their co
    76 KB (11,565 words) - 18:09, 26 January 2024
  • <big><big><big><big><big>Carlisle SynTec Systems Canada</big></big></big></big></big><br> <big><big>'''Waterproofing Roofs'''</big></big>
    4 KB (472 words) - 16:22, 31 October 2023
  • ...embrane Roof Assembly''' ('''PMRA''') the membrane functions solely as the waterproofing agent (the requirement for a vapour retarder is eliminated) and the propert ====Membranes====
    9 KB (1,317 words) - 14:38, 24 August 2017
  • <big><big>'''Waterproofing Roofs'''</big></big> ====SBS Polymer-Modified Bituminous Membranes====
    8 KB (993 words) - 20:26, 20 March 2024
  • <big><big>'''Waterproofing Roofs'''</big></big> ====BUR Systems====
    3 KB (405 words) - 20:43, 8 June 2023
  • ...and specification writers designing or applying roofing and waterproofing systems, and describes the RoofStar Guarantee Standards, Guiding Principles and Rec :[[Low-slope Membranes|Low-slope Membranes]]
    7 KB (990 words) - 20:54, 2 August 2016
  • ..., TPO, PVC) single ply membranes used for Landscaped and Vegetated roofing systems shall be fully adhered and a minimum thickness of 1.5mm (0.060"). ...tions. The minimum membrane protection must be installed by the roofing or waterproofing contractor and shall be 3 mm (1/8") asphalt core protection board or 25 mm
    7 KB (1,036 words) - 15:41, 20 July 2018
  • ..., TPO, PVC) single ply membranes used for Landscaped and Vegetated roofing systems shall be fully adhered and a minimum thickness of 1.5mm (0.060"). || 2018-J ...ed_and_Modified_Protected_Roof_Systems '''Protected and Modified Protected Membranes'''] and additional requirements set out below in '''10.1.2'''. || 2018-Janu
    22 KB (3,002 words) - 14:56, 25 September 2017
  • :'''<big>ARCHITECTURAL CONCEALED FASTENER METAL ROOFING SYSTEMS ONLY</big>''' ...metal panels may also be designed for use as structural (spanning member) systems, only their use as an architectural metal panel system (over solid deck) is
    95 KB (14,221 words) - 18:16, 19 September 2023
  • ...cted Membrane Assembly''' ('''PMA''') the membrane functions solely as the waterproofing agent (the requirement for a vapour retarder is eliminated) and the propert ====Membranes====
    8 KB (1,153 words) - 18:04, 23 May 2017