1 Part 9: EPDM Table (Combined 5, 10, 15)

Table 9.1 EPDM Membranes: RoofStar 5, 10 & 15-year Guarantees
(Applies to Field and Flashing membranes. All thicknesses shown are in mm and mils)
Exposed Roof Systems Protected Roof Systems Grade-level
Water-
proofing
Conventionally Insulated / Uninsulated Systems Built-in
Gutters
Ballasted PMR
Systems
Mechanically
Fastened
or
Induction
Welded*
Self-adhered Adhered
or
Hot-mopped
Adhered
or
Self-adhered
Loose-laid Self-adhered,
Adhered
or
Hot-mopped
Self-adhered,
Adhered
or
Hot-mopped
Type, Reinforcement, Grade Guarantee Term mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils)
EPDM (reinforced)
5 1.524 (60) 1.524 (60) 1.143 (45) 1.524 (60) 1.143 (45) 1.143 (45)
10 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60)
15 2.286 (90) 1.524 (60)
EPDM (unreinforced)
5 1.524 (60) 1.143 (45) 1.524 (60) 1.143 (45) 1.143 (45)
10 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60)
15 2.286 (90) 2.286 (90) 2.286 (90)
*Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.

2 Part 9: TPO Table (Combined 5, 10, 15)

Table 9.1 TPO Membranes: RoofStar 5, 10 & 15-year Guarantees
(Applies to Field and Flashing membranes. All thicknesses shown are in mm.)
Exposed Roof Systems Protected Roof Systems Grade-level
Water-
proofing
Conventionally Insulated / Uninsulated Systems Built-in
Gutters
Ballasted PMR
Systems
Mechanically
Fastened
or
Induction
Welded*
Self-adhered Adhered
or
Hot-mopped
Adhered
or
Self-adhered
Loose-laid Self-adhered,
Adhered
or
Hot-mopped
Self-adhered,
Adhered
or
Hot-mopped
Type, Reinforcement, Grade Guarantee Term mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils)
TPO
5 1.143 (45) 1.524 (60) 1.143 (45) 1.524 (60) 1.143 (45) 1.143 (45)
10 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60)
15 2.032 (80) 2.032 (80) 2.032 (80) 2.032 (80)
*Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.

3 Part 9: PVC Table (Combined 5, 10, 15)

Table 9.1 PVC Membranes: RoofStar 5, 10 & 15-year Guarantees
(Applies to Field and Flashing membranes. All thicknesses shown are in mm.)
Exposed Roof Systems Protected Roof Systems Grade-level
Water-
proofing
Conventionally Insulated / Uninsulated Systems Built-in
Gutters
Ballasted PMR
Systems
Mechanically
Fastened
or
Induction
Welded*
Self-adhered Adhered
or
Hot-mopped
Adhered
or
Self-adhered
Loose-laid Self-adhered,
Adhered
or
Hot-mopped
Self-adhered,
Adhered
or
Hot-mopped
Type, Reinforcement, Grade Guarantee Term mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils) mm (mils)
PVC
5 1.270 (50) 1.270 (50) 1.524 (60) 1.270 (50) 1.270 (50) 1.524 (60)
10 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60) 1.524 (60)
15 2.032 (80) 2.032 (80) 2.032 (80) 2.032 (80)
*Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.