Difference between revisions of "Template:MARS Membrane - PVC"

Jump to: navigation, search

Difference between revisions of "Template:MARS Membrane - PVC"

Line 1: Line 1:
<div class="table-responsive">
+
<div class="table-responsive">
<table class="table">
+
<table class="table">
{| class="wikitable sortable collapsible collapsed;" style="margin-left: 20pt; margin-right: auto; border: none;"
+
{| class="wikitable sortable collapsible collapsed;" style="margin-left: 20pt; margin-right: auto; border: none;"
 +
none;"
 
|+ How to use the table:
 
|+ How to use the table:
  
Line 18: Line 19:
 
! class="unsortable" | Test Facility
 
! class="unsortable" | Test Facility
 
! class="unsortable" | Test Facility Report No.
 
! class="unsortable" | Test Facility Report No.
 +
|- =BI21
 +
|| '''[[Carlisle Syntec Systems Canada]]''' || [[Materials:Sure-Flex 50 mil PVC Membrane|Sure-Flex 50 mil PVC Membrane]] || style="text-align:center;"| 1 Tested System<br>1 Tested System || style="text-align:center;"| ----<br>---- || style="text-align:center;"| -3.40<br>-2.30 || style="text-align:center;"| ----<br>---- || style="text-align:center;"| -70.00<br>-47.00 || style="text-align:center;"| Steel<br>Steel || style="text-align:center;"| [http://rpm.rcabc.org/images/d/d2/CAR-MARS1.pdf '''MARS Test Report 1''']<br>[http://rpm.rcabc.org/images/9/94/CAR-MARS2.pdf '''MARS Test Report 2'''] || style="text-align:center;"| exp. Service Inc. || style="text-align:center;"| PUB-CRU237226<br>RAP-DRU208111
 
|-
 
|-
|| '''[[Carlisle Syntec Systems Canada]]''' || [[Materials:Sure-Flex 50 mil PVC Membrane|Sure-Flex 50 mil PVC Membrane]] || style="text-align:center;"| 1 Tested System<br>1 Tested System || style="text-align:center;"| ----<br>---- || style="text-align:center;"| -3.40<br>-2.30 || style="text-align:center;"| ----<br>---- || style="text-align:center;"| -70.00<br>-47.00 || style="text-align:center;"| Steel<br>Steel || style="text-align:center;"| [http://rpm.rcabc.org/images/d/d2/CAR-MARS1.pdf '''MARS Test Report 1''']<br>[http://rpm.rcabc.org/images/9/94/CAR-MARS2.pdf '''MARS Test Report 2'''] || style="text-align:center;"| exp. Service Inc. || style="text-align:center;"| PUB-CRU237226<br>RAP-DRU208111
+
|| '''[[Johns Manville Corporation]]''' || [[Materials:JM PVC (60 mil.) |JM PVC (60 mil.)]] || style="text-align:center;"| 1 Tested System || style="text-align:center;"| - || style="text-align:center;"| -3.60 || style="text-align:center;"| - || style="text-align:center;"| -75.0 || style="text-align:center;"| - || style="text-align:center;"| [http://rpm.rcabc.org/images/9/96/JM-MARS2.pdf '''MARS Test Report 2'''] || style="text-align:center;"| exp. Service Inc. || style="text-align:center;"| PUB-DRU292249
 +
|-
 +
|| '''[[Johns Manville Corporation]]''' || [[Materials:JM PVC (80 mil.) |JM PVC (80 mil.)]] || style="text-align:center;"| 1 Tested System || style="text-align:center;"| - || style="text-align:center;"| -3.60 || style="text-align:center;"| - || style="text-align:center;"| -75.0 || style="text-align:center;"| - || style="text-align:center;"| [http://rpm.rcabc.org/images/9/96/JM-MARS2.pdf '''MARS Test Report 2'''] || style="text-align:center;"| exp. Service Inc. || style="text-align:center;"| PUB-DRU292249
 
|-
 
|-
 
|}
 
|}
 
   </table>
 
   </table>
 
</div>
 
</div>

Revision as of 18:12, 26 June 2018

none;"
How to use the table:
  1. In the table below look for maximum wind uplift values that exceed the requirements determined through the RCI calculator;

    (NOTE: while the reports show two different values for tested maximum assembly strength, the RPM tables display only the values adjusted for the required safety factor of 1.5)

  2. Open the report for the tested assembly that fits with the design parameters you have chosen and calculated, and examine the report. It will break down the assembly by its components. Ensure all the key components (Secondary materials, such as deck overlay, insulation and insulation overlay) are accepted by the RoofStar Guarantee Program (note that fasteners and adhesives currently are not listed in this Manual - use the materials specified in the wind test report, or consult the membrane manufacturer);
  3. In cases where a tested Secondary material is not accepted by the RoofStar Guarantee Program, look for alternates which often are published in the each report. In the absence of published alternates, locate a possible alternate in the Accepted Materials section of this Manual. If you are unsure about compatibility, contact the RCABC.
Manufacturer Product Name Number of Tested Systems
(per report)
kPa (Low) kPa (High) Psf (Low) Psf (High) Deck Type Downloadable Test Report Test Facility Test Facility Report No.
Carlisle Syntec Systems Canada Sure-Flex 50 mil PVC Membrane 1 Tested System
1 Tested System
----
----
-3.40
-2.30
----
----
-70.00
-47.00
Steel
Steel
MARS Test Report 1
MARS Test Report 2
exp. Service Inc. PUB-CRU237226
RAP-DRU208111
Johns Manville Corporation JM PVC (60 mil.) 1 Tested System - -3.60 - -75.0 - MARS Test Report 2 exp. Service Inc. PUB-DRU292249
Johns Manville Corporation JM PVC (80 mil.) 1 Tested System - -3.60 - -75.0 - MARS Test Report 2 exp. Service Inc. PUB-DRU292249