Division D - Construction Details


WP Details:F1.7.5 (Expansion Joint - Deck Level)

Notice to Reader
Images used in a Construction Detail are representative and not prescriptive. Nor are they necessarily drawn to scale. Rather, they are provided to visually convey the requirements of the Standard they represent. Unless otherwise required by the Standard, dimensions, the selection of materials and their application remains the responsibility of the Design Authority.

The full text of the referenced requirements in the Standard may be read by using the blue hyperlinks
Waterproofing Details for Plazas, Promenades and Terraces

F1.7.5.jpg

1 WORK INCLUDED

(1) Primary Waterproofing Membrane
Fully adhered to acceptable substrates (concrete slab depicted) install as per the Standard, together with Membrane Manufacturer's installation specifications.
(2) Membrane flashing (stripping)
Carried up wall minimum 200 mm (8") above deck surface and or a minimum of 100mm (4") above top surface of waterproofing assembly.
(3) Membrane Primer or Adhesive
Proprietary primer or adhesive application and quantities as directed by Membrane Manufacturer's published application specifications.
(4) Expansion Joint
Proprietary elastomeric expansion joint system compatible with waterproofing membrane system approved by membrane manufacturer and accepted by the RoofStar Guarantee Program. Designed to accommodate specific horizontal building movements and compliant with Section 3.2, Expansion Joints.
(5) Protection Board/Mat
Proprietary membrane protection board or mat approved by membrane manufacture compatible with waterproofing membrane system, and compliant with RoofStar Guarantee Standards.
(6) Insulation
Optional: Extruded, Expanded Polystyrene, Type 4, CAN/ULC-S701-97, compressive strength of 240 kpa (35 psi).
(7) Filter Mat
Synthetic permeable fabric required over extruded, expanded polystyrene insulation overburdened with pavers, growing mediums, sand and gravel beds for unit masonry, etc.
(8) Metal Cap or Coping Flashing
Must overlap exterior wall finish. See Section 16.3, Attachment for fastening and additional requirements.
(9) Metal Base Flashing
Required on all waterproofing assemblies. Flashing lengths joined by use of S-locks or standing seam joints.

2 WORK BY OTHERS

(A) Acceptable Deck
Concrete slab shown.

NOTE: See the Standard for additional requirements.


Back to Grade-level Waterproofing Construction Details